HomeMy WebLinkAboutAGENDA REPORT 2021 0622 PC ITEM 08BCITY OF MOORPARK, CALIFORNIA Planning Commission Meeting of June 22, 2021 Approved Staff Recommendation with Modified Conditions of Approval as Proposed by the ACTION: Commission. BY: K. Valencia Item: 8.6. B. Consider a Resolution Recommending Approval of Commercial Planned Development No. 2020-01 and Conditional Use Permit No. 2020-04, to Allow the Demolition of an Existing 2,300 Square -foot Building and Develop a 6,186 Square -Foot, Single -Story Auto Repair Shop and Associated Site Improvements Located at 13816 Princeton Avenue, and Making a Determination of Exemption Pursuant to the California Environmental Quality. Act (CE A) in Connection Therewith, On the Application of Abdul Salehi. Staff Recommendation: 1) Open the public hearing, accept public testimony., and close the public hearing; and 2) Adopt Resolution No. 2021-657 recommending approval to the City Council of Commercial Planned Development No. 2020-01 and Conditional Use Permit No. 2020-04. (Staff: Shanna Farley Judkins) Item: 8.13. MOORPARK PLANNING COMMISSION AGENDA REPORT TO: Honorable Planning Commission FROM: Shanna Farley -Judkins, Principal Planner DATE: 06/22/21 Regular Meeting SUBJECT: Consider a Resolution Recommending Approval of Commercial Planned Development No. 2020-01 and Conditional Use Permit No. 2020-04, to Allow the Demolition of an Existing 2,300 Square -foot Building and Develop a 6,186 Square -Foot, Single -Story Auto Repair Shop and Associated Site Improvements Located at 13816 Princeton Avenue, and Making a Determination of Exemption Pursuant to the California Environmental Quality Act (CEQA) in Connection Therewith, On the Application of Abdul Salehi STAFF RECOMMENDATION Open the public hearing, accept public testimony and close the public hearing; and 2. Adopt Resolution No. 2021-657 recommending approval to the City Council of Commercial Planned Development No. 2020-01 and Conditional Use Permit No. 2020-04. PROJECT DESCRIPTION On August 5, 2020, Abdul Salehi, on behalf of Mir Rafiq, President of Rafiq Inc., submitted an application for a Commercial Planned Development (CDP) and Conditional Use Permit (CUP) to allow the demolition of an existing 2,300 square -foot building and the development of a new 6,186 square -foot, single -story auto repair shop and associated site improvements at 13816 Princeton Avenue (Attachments 1 and 2). The auto shop would include light service and repair, such as: brakes, oil changes, tires and shock sales and installation, and tune-ups. (Attachment 3). The Project is located within the Commercial Planned Development (CPD) zoning district and the Downtown Specific Plan (DTSP). The Project is subject to applicable provisions of the City's Zoning Ordinance and DTSP. The DTSP sets forth a vision for the downtown area that includes architectural and site development standards, as well as guidelines for commercial corridors. Honorable Planning Commission CPD No. 2020-01 and CUP No. 2020-04 06/22/2021 Regular Meeting Page 2 Pursuant to Section 17.20.060 of the Moorpark Municipal Code (MMC), a CPD is required to allow construction of a new building with a floor area of 2,500 square feet or greater. Pursuant to Section 17.20.060.A.3.a of the MMC, a CUP is required to allow light auto repair when proposed within 100 feet of a residentially -zoned property. The nearest residential lot is located approximately 85 feet to the north of the Project site. The Planning Commission typically renders a decision on a CUP application; however, because this Project involves City Council consideration of the CPD, staff is requesting the Planning Commission's recommendation to the City Council on all permits associated with the Project. This will allow the City Council to consider the complete proposal. BACKGROUND The 0.57 -acre Project site was developed with the existing 2,300 square -foot commercial building, a parking lot, and associated site improvements in 1961. The site was previously occupied by several restaurants (Rock and Roll Pizza and Chuy's Mesquite Broiler). On October 23, 2018, the Planning Commission approved CUP No. 2018-02 to allow the operation of an auto dealership (First Auto Sales), which has operated on the site since that time. EXISTING AND SURROUNDING LAND USES The following table summarizes the General Plan, zoning / Downtown Specific Plan designation, and existing land uses on the subject property and within the vicinity. Surrounding Land Uses Direction General Plan Zoning / Specific PlanLand Land Use Use Designation Commercial Planned Downtown Specific Development (CPD) Commercial Project Site Plan (SP -D) with Downtown Specific Plan Building and Overlay Zone Parking Lot Residential Planned Downtown Specific Development (RPD -15U) North Plan (SP -D) with Downtown Specific Plan Residential Overlay Zone Commercial Planned Railroad and South Downtown Specific Development ment CPD with p (CPD) Community Plan (SP -D) Downtown Specific Plan Center Overlay Zone Industrial Park (M-1) with East Downtown Specific Downtown Specific Plan Trench Shoring Plan (SP -D) Overlay Zone Honorable Planning Commission CPD No. 2020-01 and CUP No. 2020-04 06/22/2021 Regular Meeting Page 3 Commercial Planned West Downtown Specific Development (CPD) with Commercial Plan (SP -D) Downtown Specific Plan Overlay Zone PROJECT ANALYSIS General Discussion: The proposed auto repair shop would be located within a new 6,186 square -foot building which would replace an existing commercial building and parking lot (Attachment 5). The auto shop would include light service and repair, such as brakes, oil changes, tires and shock sales and installation, and tune-ups. The auto shop would include six service bays with roll -up doors. Vehicles would be repaired inside the bays, with no work or storage proposed outdoors. The auto shop would also include a small customer service area, office, and restrooms. The auto shop would operate from 7:00 a.m. to 7:00 p.m., Monday through Saturday and would be closed on Sunday. The auto shop would employ approximately three employees. Outdoor parking areas would be reserved for employee and customer parking. All repair and maintenance service would occur within the building. Outdoor storage is not proposed. General Plan, Specific Plan, and Zoning Consistency: The General Plan land use designation for the Project site is Downtown Specific Plan (DTSP). The zoning designation for the Project site is Commercial Planned Development (CPD), which is consistent with the General Plan designation. As outlined in this report, the Project is designed to comply with all applicable development standards of the zoning code. The DTSP concentrates on long range planning for the downtown core, focusing on the High Street and Moorpark Avenue corridors, and the surrounding residential districts. The Plan encourages land uses in and adjacent to the downtown core that are compatible with the planned downtown land uses. The proposed auto shop is a permitted land use by zoning and the DTSP with an approved CUP. This Project is consistent with the following Goals and Policies of the General Plan Land Use Element: • Goal 1: Attain a balanced City growth pattern which includes a full mix of land uses. o Policy 1.1: New development and redevelopment shall be orderly with respect to location, timing, and density/intensity; consistent with the provision of local public services and facilities; and compatible with the overall suburban rural community character. o Policy 1.4: New development and redevelopment shall be coordinated so that the existing and planned capacity of public facilities and services shall not be adversely impacted. Honorable Planning Commission CPD No. 2020-01 and CUP No. 2020-04 06/22/2021 Regular Meeting Page 4 • Goals 7: Provide for a variety of commercial facilities which serve community residents and meet regional needs. o Policy 7.1: Commercial development should be clustered in compact areas, rather than extended along streets and highways (i.e., strip commercial development). o Policy 7.4: The City shall encourage adjacent commercial developments to coordinate design with regard to access, parking, and architectural features. • Goal 8: Provide for new commercial development which is compatible with surrounding land uses. o Policy 8.1: New commercial uses shall be compatible in scale and character with all adjacent commercial uses. o Policy 8.2: Commercial development shall incorporate design features such as walls, landscaping and setbacks, and include height and lighting restrictions so as to minimize adverse impacts on adjacent uses and enhance the visual characteristics of the area. o Policy 8.3: Automobile and truck access to commercial properties shall be located so as to minimize impacts to adjacent uses. o Policy 8.4: Commercial uses shall be well maintained to enhance the visual characteristics of the area. Arrhitarfi ira- The DTSP provides guidance for development in the downtown to ensure compatible design and character of projects and their relationship with the surrounding community. DTSP Section 2.2.7 provides design and landscape guidelines for properties in the CPD zone within the DTSP area. The Project incorporates colors and materials in earth tone colors, using a mix of brick veneer and stucco exteriors, with column elements on the corners and along long exterior elevations, consistent with the colors and materials outlined in the DTSP. The Project's roof elements are varied in height and incorporate a cornice trim to mimic other commercial buildings in the DTSP. The proposed building includes large, recessed store front windows along the frontage and side facing entrance windows and doors and an awning over the entrance to provide visual interest and pedestrian orientation. The DTSP requires that architectural building form and massing within the C -PD zone resemble Early American style architecture. The proposed architecture, including the colors, brick veneer, cornices, and brushed metal light fixtures, is consistent with and complementary to adjacent development including the 76 Station and auto service buildings directly to the west of the subject property. A special condition of approval is proposed to require that additional architectural details be added to the south and east elevations of the structure, towards the rear of the property. The wall planes are currently blank in these areas. The proposed condition will Honorable Planning Commission CPD No. 2020-01 and CUP No. 2020-04 06/22/2021 Regular Meeting Page 5 result in a consistent level of detail on all four sides of the building and would also help deter graffiti. Setbacks and Heiaht: Table 17.24.035 of the City Code establishes the development standards for properties within the CPD zone, including setbacks, height and building coverage. The proposed Project complies with all applicable development requirements of the CPD zone, as shown in the table below. General CPD Zone Proposed Commercial Complies Requirements Planned Development Listed Under Development Table 17.24.035 Standard A. Floor area ratio, 0.25 <0.25 maximum Yes (6,196 sq. ft.) (6,186 sq. ft.) C. Front yard 20 feet 20 feet Yes setback, minimum D. Interior side yard setback, 5 feet 5 feet Yes minimum F. Rear yard 0 feet 2 feet 1 inch Yes setback, minimum G. Building and Yes, with an approved CPD structure height, By permit 25 feet and CUP maximum In the CPD zone, the height of the structure is established with each development permit. The proposed building height of 25 feet is generally consistent with the height of existing commercial development in the vicinity of the Project site, including Sharma Engineer Contractors at 25 feet, Hi -Tech Auto at 20 feet, 76 Gas Station at 22 feet 10 inches, Moorpark Centre at 25 feet, Fire Station 42 at 28 feet, and Trench Shoring at approximately 25 feet. Circulatinn- Access to the site will be provided by an existing driveway along Princeton Avenue. The existing driveway would be widened to accommodate a larger vehicle turning radius. Larger vehicles that access the site would include waste hauling trucks and delivery vehicles. A second existing driveway on the eastern side of the Princeton Avenue frontage would be abandoned and replaced with sidewalk, curb, and planter. Pedestrian access to the proposed building would be provided by the sidewalk along Princeton Avenue and on-site walkway. The Project's proposed circulation and driveway improvements provide compliant access for waste hauling vehicles, as shown on page A-0 of Attachment 5. Proposed improvements to the sidewalk, driveway and areas within Honorable Planning Commission CPD No. 2020-01 and CUP No. 2020-04 06/22/2021 Regular Meeting Page 6 the right-of-way were reviewed by the Public Works Department and found consistent with MMC Title 12 Streets, Sidewalks and Public Spaces. Parking and Loading: The following table summarizes the Project compliance with the off-street parking requirements of the City Code. No loading spaces are required for the proposed Project. Building Total Parking Total Parking Size Display Area Service Bays Office Spaces Spaces Required Provided Proposed 6,186 1 space / 1 space/ 1 space / square -foot 1,000 square service bay 300 square 8 10 commercial feet feet building Landscaping: As proposed and conditioned, the project complies with all applicable landscape standards. Of note, the proposed Project provides 29% of the parking area as landscaping, well beyond the minimum'of 10% required by MMC Section 17.32.070. The landscape plan is also consistent with site entrance and exit visibility standards, as required by MMC Section 17.32.050(A)(2). This ensures that motorists coming into and out of the site from Princeton will have clear lines of site to cars and pedestrians. The conceptual landscape plan includes a variety of trees, shrubs and groundcover consistent with the DTSP landscape requirements and City's Landscape Standards, including the screening of parking areas and utility structures. The landscape plan also proposes improved parkway landscaping within the right-of-way. The proposed Landscape Plan (page L-1 of Attachment 5) identifies the removal of three existing laurel bay trees on the Project site. Consistent with MMC Section 12.12.050 and as outlined in the Conditions of Approval, a tree survey shall be required to consider the appraised value of the trees to be removed. Enhanced replacement landscaping of equal or greater value of the trees to be removed, as determined by the Community Development Director, must be installed in accordance with the current applicable provisions of the MMC. The proposed Project includes the removal of existing site improvements, including existing chain link fencing and vines along the southern property boundary and existing planter walls along the eastern property line. The existing fence along the eastern property boundary would remain and a new six -foot -high concrete block wall would be installed along the southwestern and southeastern portion of the property line, to align with the proposed building. The proposed concrete block wall would be finished in a beige color to match the primary building color. The proposed building runs along the eastern property line, setback five feet. Grading and Drainage: Grading and drainage improvements are proposed on-site within the new parking and landscaped areas. The Project has been designed to provide for all necessary on-site Honorable Planning Commission CPD No. 2020-01 and CUP No. 2020-04 06/22/2021 Regular Meeting Page 7 storm water retention and infiltration improvements including compliance with National Pollution Discharge Elimination System (NPDES) requirements. The Project would include compliance with the Construction General Permit, which requires development of a Storm Water Pollution Prevention Plan (SWPPP). Final grading and drainage plans shall be submitted as a Condition of Approval, to the satisfaction of the City Engineer and Public Works Director. Moorpark Police Department: The Moorpark Police Department has reviewed this application and has recommended several conditions of approval which are included in the draft resolution (Attachment 6). With the inclusion of these conditions, the Police Department has no concerns regarding the proposed use. Operations: The proposed Special Conditions of Approval included with the draft resolution (Attachment 6) address a variety of operational issues applicable to commercial and auto repair uses to ensure compatibility with surrounding uses. Conditions include the requirement to conduct all auto repair within the building, maintain all storage of goods and materials indoors, provide adequate shade and lighting, and require registration of a security system with the Police Department. Undergrounding of Utilities: The applicant also requests that the City Council approve a waiver from Standard Condition of Approval No. 145 of Resolution No. 2009-2799 which requires that: Prior to issuance of the first building permit, all existing and proposed utilities, including electrical transmission lines less than 67Kv, must be under -grounded consistent with plans approved by the City Engineer, Public Works Director and Community Development Director. Any exceptions must be approved by the City Council. One wooden utility pole owned Southern California Edison (SCE) is currently located on the north frontage of the property and one wooden on-site utility pole is located on the western side of the Project site. The existing wooden poles and utility lines on the site are less than 67Kv and would be required to be undergrounded as part of the Project. The applicant is aware of this condition and is willing to comply; however, in addition to the one wooden pole off-site and one wooden pole on-site, SCE is requiring the applicant to underground two additional off-site utility poles and one support pole located within the vicinity of the subject property, one pole to the east and two poles to the west of the Project site. The applicant proposes to underground the onsite utility pole and utility lines located along the western property boundary and install a new electrical transformer box at the southeast corner of the site. The applicant requests that the City Council waive the requirement to under -ground the utility pole on the frontage of the property, as its removal would require the removal of two additional utility poles to the west and east of the subject site, one structural pole, and require trenching well beyond the Project site. The applicant's request and diagrams are included as Attachment 4. The City Council would consider the request following action on the project by the Planning Commission. Honorable Planning Commission CPD No. 2020-01 and CUP No. 2020-04 06/22/2021 Regular Meeting Page 8 Commercial Planned Development Permit Findings: 1. The site design, including structure location, size, height, setbacks, massing, scale, architectural style and colors, and landscaping, is consistent with the provisions of the general plan, any applicable specific plans, zoning ordinance, and any other applicable regulations. The Project is consistent with the applicable development standards outlined in the DTSP and the SP -D General Plan land use designation, the CPD zoning designation, and the Landscape Standards and Guidelines. 2. The site design would not create negative impacts on or impair the utility of properties, structures or uses in the surrounding area. As proposed and conditioned, the Project site provides required parking, access improvements, site lighting, utility upgrades and landscape improvements necessary to serve the proposed use and prevent impacts to adjacent properties. The proposed conditions would ensure the proposed use would not negatively impact the surrounding area. Conditions require a lighting coverage plan to ensure adequate lighting controlled by motion sensors, a security system that is registered with the Police Department, and application of graffiti resistant paint and coating on low building faces. 3. The proposed uses are compatible with the existing and permitted uses in the surrounding area. The Project is compatible to similar nearby uses including adjacent automotive shops and a gas station. The Project site is also located along a portion of Princeton Avenue that transitions from retail commercial uses to industrial commercial uses. Conditional Use Permit Findings: 1. The proposed use is consistent with the provisions of the General Plan, Zoning Ordinance, and all applicable regulations as outlined in the Agenda Report. 2. The proposed use, as conditioned, is compatible with both existing and permitted land uses in the surrounding area in that an auto shop conducting light service and repairs is consistent with existing commercial uses within DTSP area. 3. The proposed use, as conditioned, is compatible with the scale, visual character, and design of surrounding properties in that the Project improvements and building design would provide architecture, landscaping, access, parking, and lighting elements consistent with the DTSP and Zoning Ordinance. 4. The proposed use, as conditioned, would not be obnoxious or harmful, or impair the utility of neighboring property or uses in that conditions of approval have been added to ensure adequate lighting controlled by motion sensors, a security system that is registered with the Police Department, application of graffiti resistant paint and coasting on low building faces, and all repair and maintenance of vehicles Honorable Planning Commission CPD No. 2020-01 and CUP No. 2020-04 06/22/2021 Regular Meeting Page 9 would occur within the service bays. 5. The proposed use, as conditioned, would not be detrimental to the public health, safety, convenience, or welfare in that the auto shop operation consists of the light service and repair of commercial vehicles, such as brakes, oil changes, tires and shock sales and installation, and tune-ups. PROCESSING TIME LIMITS Time limits have been established for the processing of development projects under the Permit Streamlining Act (Government Code Title 7, Division 1, Chapter 4.5), the Subdivision Map Act (Government Code Title 7, Division 2), and the California Environmental Quality Act Statutes and Guidelines (Public Resources Code Division 13, and California Code of Regulations, Title 14, Chapter 3). Under the applicable provisions of these regulations, the following timelines have been established for action on this Project: Date Application Filed: August 5, 2020 Date Application Determined Complete: February 25, 2021 City Council Action Deadline: July 25, 2021 ENVIRONMENTAL DETERMINATION In accordance with the City's environmental review procedures adopted by resolution, the Community Development Director or designee determines the level of review necessary for a project to comply with the California Environmental Quality Act (CEQA). Some projects may be exempt from review based upon a specific category listed in CEQA. Other projects may be exempt under a general rule that environmental review is not necessary where it can be determined that there would be no possibility of a significant effect upon the environment. A project which does not qualify for an exemption requires the preparation of an Initial Study to assess the level of potential environmental impacts. The Director has reviewed this Project and found it to be Categorically Exempt in accordance with Sections 15332 (Class 32: In -Fill Development Projects) of the CEQA Guidelines. Therefore, Staff has determined that there is no substantial evidence that the Project would have a significant effect on the environment. Section 15332 applies to in- fill development provided that the following conditions exist: a) The project is consistent with the applicable General Plan designation and all applicable General Plan policies, as well as with applicable zoning designation and regulations. As outlined in this Agenda Report, the Project is consistent with all applicable policies of the General Plan, zoning, and DTSP. b) The proposed development occurs within city limits on a project site of no more than five acres substantially surrounded by urban uses. Honorable Planning Commission CPD No. 2020-01 and CUP No. 2020-04 06/22/2021 Regular Meeting Page 10 As outlined in this Agenda Report, the .57 -acre Project site is located within city limits and surrounded by developed uses. c) The project site has no value as habitat for endangered, rare, or threatened species. As outlined in this Agenda Report, the Project site has been completely developed and paved since 1961. No habitat or native vegetation was observed on the property and the site is not located within any identified habitat areal where biological resources may exist. d) Approval of the project would not result in any significant effects relating to traffic, noise, air quality, or water quality. As proposed and with the inclusion of the draft conditions of approval, the Project would not result in any significant effects related to traffic, noise, air quality, or water quality. e) The site can be adequately served by all required utilities and public services. As proposed and with the inclusion of the draft conditions of approval, the Project would be adequately served by all required utilities and public services. NOTICING Public Notice for this meeting was provided in accordance with Chapter 17.44.070 of the Zoning Ordinance, as follows: 1. Publication. The notice of the public hearing was published in the Ventura County Star on June 11, 2021. 2. Mailing. The notice of the public hearing was mailed on June 11, 2021, to owners of real property, as identified on the latest adjusted Ventura County Tax Assessor Rolls, within one -thousand (1,000) feet of the exterior boundaries of the assessor's parcel(s) subject to the hearing. 3. Sign. One 32 square -foot sign was placed on the street frontage on June 11, 2021. ATTACHMENTS: 1. Location Map 2. Aerial Map 3. Applicant Narrative 4. Utility Undergrounding Waiver Request and Diagram 5. Site Plan, Floor Plan, Colors, Materials, Lighting, and Civil Plan 6. Draft Resolution with Conditions of Approval 1 PlaceWorks, Moorpark 2020— An Examination of the City's Existing Conditions (2020), Figure 7.3-9 W, -1 Spring Rd 10 61) -F- LLJ CS UJ C? D QJ CL E 0 ui a. N C) 71 %0 Cn Vi T-7 qj > CO —'r P C) 0 C) 6N Ll N Q 0 E C) L) TM CD 0 lu LM 5 > OL E D rii nJ E c 0 0 CL fj) ALr- 6 OWN. I'A Abdul Salehi, Architect 14711 Dartmouth Circle, Tustin, CA 92780 Tel. 949-701-3346 March 16, 2021 Miss. Shanna Farley -Judkins City of Moorpark Planning Division 799 Moorpark Avenue Moorpark, CA 93021 RE: Project Description Project: New Auto Repair Shop Dear Shanna: We are proposing to demo existing 2,300 s.f single story building currently used as used car sales. We are proposing to construct a new single story 6,186 s.f. building for Auto Repair use. We will modify all existing parking, will close one existing curb cut drive to the site and will widen the second existing curb cut dive to the site. We will provide new landscape planters, new parking and a new trash enclosure at the rear south end of property. Will install a new electrical transformer for power by Edison Co. that will be located near the new trash enclosure. The new building will have a customer service area with restroom for customers and employees and an office, There will be a total of five service bays for auto repair. The new building will have storefront on west and north side, walls will be traditional plaster with face brick accent pilasters and steel overhead doors. The site will have new trees and planters. The property owner will construct this building for his own use. He is currently leasing the property on west of the site. His business is called Hi -Tech Auto & Tire Center that has been in operation for over 30 years located at 13806 Princeton Avenue. Operation hours for the business will be: Mon-Saturday:7:00am to 7:OOpm Sincerely, Abdul Salehi Principal ATTACHMENT 3 ASAD Group 14711 Dartmouth Circle, Tustin, CA 92780 Tel. 949-701-3346 June 10, 2021 City Of Moorpark 799 Moorpark Avenue Moorpark, CA 93021 Attention: Douglas Spondello PROJECT NUMBER: CPD No. 2020-01 and CUP No. 2020-04 PROJECT DESCRIPTION New Single Story Auto Repair Shop Building ADDRESS: 13816 Princeton Avenue, Moorpark, CA 93021 RE: Standard Condition of Approval No. 145 — Request for a Waiver Dear Doug, This letter is a request for a waiver of the requirements to have the power poles along Princeton Avenue placed underground due to site conditions and extent of work required per SCE recommendations to comply with standard condition of approval No. 145. The project site has one power pole on west of property. This power pole also provides power to existing transformer that is located on west property site currently Hi -Tech Auto. Existing 76R Gas station is also wired to this transformer via underground wires. An existing street light arm is attached to this power pole that will be removed with power pole. This will require adding a new street light pole in this location. The next power pole to the west is about 100 feet to the west at 76R property line. The third power pole to the east is about 73 feet from the project property line, currently Trench Shoring Company. We have contacted Southern California Edison (SCE) to review and determine the extent of work related to removal of overhead wires and power pole. SCE has advised us that removal of the overhead wires just in front of this project property and removal of just one power pole is not feasible. Per SCE two power poles must be removed, one at 76R and Hi -Tech Auto property line, second at west end of this project site. The trenching and underground conduits must be installed from west, starting at 76R and Hi - Tech Auto property line all the way to the east existing power pole located on Trench Shoring Company site. This brings the total of new trench work to about 297 feet, when current project frontage is 125'-4" wide. The project property owner Mr. Rafiq is willing to comply with the standard condition of approval No. 145 for his property and 125'-4" frontage facing Princeton Avenue. However he cannot do the work required by SCE on adjacent properties. The work on adjacent properties is the responsibility of each property owner, including adding one new street light pole. The applicant proposes to underground the exiting power pole on the western side of the property, underground the onsite utility lines and install a new transformer to the rear of the project site. The applicant requests a waiver from the undergrounding requirement for the northern utility pole located along the frontage due to the burden of removing two additional utility poles on the east and west of the project site and trenching at least 172' feet beyond the subject project site. Attached is a site plan that explains the scope of design work per SCE recommendations for your review. We are hope full to have a final solution to resolve the rule 145 issue so we can move forward with our project. Sincerely, Abdul Salehi Principal 1 Cc: Mr. Wahed Rafiq ATTACHMENT 4 wool O tw 09.995 SOPS ,X3 ,3 lo: . o_- 0 lit CIE - 84 42' 42' O tw 09.995 SOPS ,X3 ,3 o_- 0 lit CIE - II 1 FIN -AV N0I33NI6d l�lI�'1H NOlIDNI�d W ill I� 0 III z �w ap ' n 1..� O z IIIA QZ N Oi� � U. Z Z LU W W � W G� a_ I I I I I I 11°1,1°1 sia£ i p c0 as O~ W ill I� ! III z z n 1..� O z IIIA QZ N Oi� � U. Z Z LU W W � W G� Q 0 o � p c0 � O O~ o O 01 CVOb TvV : W z n 1..� O z LUOQ N WrywU z—U OQ Z Z LU W W � G� Q 0 o � p c0 � O O~ o O Q� CVOb TvV : z u O N a Z LU Q 3AV NOi30MINd a n a d d Oh m$ O m 0 0 �f�f � mo Q � s ILII w'_w o -_i '!.SE w x o> ¢Io w w li �I II i l Iii d I II _____—__' NI ZZ _ rl II ° U III II d v I R S III o P II ° d w K I I 1 I F I opo ��x u I, ill h n I, -n------- o W -�lu ------------ ii 12 ¢ m ii it I' I w= I uh jl, I, y w Z rl II II r I I ILI � H N I I I I III I j� __________ I' II II ` ZF°IF_- oUf Vz h3 II Ir, z II II II II II " Ni qq II . r I II gg = I II d111 Qw� waw Q C5 ii I' II 2 ol I, w II II ` r�i FN i II III I r Kw Xw u ii j o Ili �I�i I � 0 0 w I I I 00 0 _ inNIAd NOAONNd 3nN]AV N011ONNd a IN | |&i a I � _ � {] 3nN]AV N011ONNd a IN O Lun o O Baia00 O Lun O O Lun 0 ID � ��� \0 ! J � \ < \}(� |§! /B2: - :;! \§ \LM _ }) a4!! \j )1')( 0 ID � ��� \0 J � \}(� /B2: _ ] \§ \LM }) 0 ID � a R 5 4 ,gk s'a o a a N i E U z Q � O O %a 0 > z a U Z z a o� am z C www = z /\f ` y J l�Jz ��a zoo= o ¢ =0iz W Zp W J n I I I I I I I( I I I=tela �f^S a M� w %a wG> > z a U Z z J a J 0 J W J l�Jz ��a zoo= o ¢ .n 000p zw�w� W W J 0 z< W nU > H I } VU --- l W z m o z o O 0 a z0 J W a .n I } ¢ m a ° a of Z 0 w O N M ? S S � cif s } z z w i VMX-II LED Specifications `Universal Arm Mount (UAM)Version Shown. Ordering Information Project Name: Catalog Number: Type: The VMX-11 LED Series offers clean, functional styling that is defined by its sleek low profile design and rugged construction. It combines the latest LED technology, advanced LED thermal management and provides outdoor lighting that is both energy efficient and aesthetically pleasing. The LED's performance and the driver's life are maximized by enclosing them in two separate cast aluminum housings. Easy tool -less access for mounting and maintenance. The LED light assemblies come with 48 to 96 LEDs. Eight optical distribution patterns are available. Choose between 3000, 4000 or 5000 Kelvin temperature of the LEDs. A durable polyester powder coat finish is guaranteed for five years; and is available in standard or custom colors. The VMX-II LED series is an exceptional choice for commercial parking lots, office complexes, architectural projects, and other general lighting projects. MODEL OPTICS LEDs CURRENT KELVIN VOLTAGE MOUNTING FINISH OPTIONS OPTIONS OPTIONS VMX-II T1 48LC 3 3K UNV AM BZ Type 1 que e 350mA 3000K 120-277V Arm Mount Bronze T2 64LC 5 Universa' Round Pole 8 SAM BK Type 2 Height 530mA 4K 347V Straight Arm Black WSC-40 80LC PER 4000K Plate Mount W/ Mounting Mounti ROT-R 7PINPER 7 RotatedOptics 5 Terminal Block SBK Photc 700mA Receptacle 480V New Construction) Smoot Type 3 96LC Dimming Driver 5K Optics Left Side Black 0-1ovDDiimming 10 5000K Driver arm fitter cutoff shield T4 ECLS 1050mA Not available RPP 4" Egg Crate Louver Shield UAM Universal ArmW/ WH Type 4 cutoff shield in 96LC ADJLS Terminal Block White Louver Light LCLS VWC Mount (Retrofit) Leftside Visionaire cutoff shield Wireless BD SWH T4A 'Consult Shield HS MAF Type 4 Mast Arm Fitter White Automotive KM GP T5 Knuckle Mount Graphite Type 5 WM GY Wall Mount Grey T5W *Requires BAWP TWide SL AWM ilver Adjustable Wall Metallic Mount T5WR Type 5 'Round Pole CC Wide Round Plate Custom Adapters (RPP) Color are to be ordered separately. BAWP to be ordered separately V VISIONAIRE LIGHTING 236 PCR -120 WSC-8 UPMA-S Motion Sensor UniversalI PCR -208 8' Mounting que e PCR -240 Height pole Mount Adaptor PCR -277 WSC-20 UPMA-R PCR -347 Motion Sensor 9-20' Universa' Round Pole PCR -480 Mounting Mount Adaptor Photocell & Height Receptacle BAWP WSC-40 Cast Wall PER Motion Sensor Plate 5PINPER Mounting Mounti ROT-R 7PINPER Height RotatedOptics 3, G, cr7 Pr Right Side Photc Receptacle ROT -L w/shorting cap Requires Rotated Dimming Driver Optics Left Side UMAP 0-1ovDDiimming Universal Mast Backside Driver arm fitter cutoff shield RPP -3" ECLS RPP 4" Egg Crate Louver Shield RCLS Rightside RPP -5" cutoff shield Round Pole ADJLS Plate Adaptor Adjustable Louver Light LCLS VWC Shield Leftside Visionaire cutoff shield Wireless BD Controls Barn Door 'Consult Shield HS Factory House shield Features & Specifications Heatsink Cast aluminum heatsink with integral cooling fins for thermal management. Mounting Arm/Driver Compartment Durable two-piece die cast aluminum driver compartment utilizes stainless steel hardware and sealed with a one-piece silicone gasket. Thermal Management The VMX-II series provides excellent thermal management by mounting the LEDs to the substantial heat sink of the housing. This enables the Luminaire to withstand higher ambient temperatures and driver currents without degrading LED life. • The L70 test determines the point in an LEDs life when it reaches 70 percent of its initial output. The VMX-II series LEDs have been determined to last 100,000+ hours in 25° C environments when driven at 350 mA. Optical System • The highest lumen output, LEDs are utilized in the VMX-II series. IES distribution Types I, Il, II, III, IV, IV -A, V, V -WR are available. The optical system qualifies as IES full cutoff to restrict light trespass, glare and light pollution. • CRI values are 70. Quali-Guard® Finish • The finish is a Quali-Guard® textured, chemically pretreated through a multiple -stage washer, electrostatically applied, thermoset polyester powder coat finish, with a minimum of 3-5 millimeter thickness. Finish is oven -baked at 400° F to promote maximum adherence and finish hardness. All finishes are available in standard and custom colors. • Finish is guaranteed for five (5) years. & Electrical Assembly • The VMX-II LED series is supplied with a choice of 350, 530, 700 or 1050 mA high-performance LED drivers that accept 120v thru 480v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40DC operations. 10 kV surge protector supplied as standard. Terminal block supplied as standard on AM, SAM and UAM as standard Warranty • Five (5) year Limited Warranty on entire system, including finish. For full warranty information, please visit visionairelighting.com. Options Photocell & Receptacle Photo Receptacle with Shorting Cap 0-10v Dimming Driver Motion Sensor Wireless Control Round pole plate adapter Universal Pole Mount Adaptor Cast Wall Plate Rotated Optics Cutoff Louver Shielding (CLS) Listings The VMX-II Series is cUL Listed IP65 Rated Housing ANSI Certification Powder Coated Tough IDA Certification DLC Listed COATED IP65 nNs► IP65 C VL US ,s RATED 0 Q D (MM -1 DeslgnLights Consortium (DLC) qualified Product. Some configurations of this product family may ^c ne DesignLights Consortium (DLC) listed, please refer to the DLC qualified products list to confirm :fisted configurations. http://www.designlights.org/ 3000K must be selected with a fixed mount for IDA certification. Fixed mount must be selected for IDA dark sky certification. 19645 Rancho Way -Rancho Dominguez, CA 90220 Phone: 310 512 6480 Fax 310 51.2 6486 www.visionairelighting.com 237 VMX-11 - ELECTRICAL LOAD (A) Ordering Nomenclature System Watts 120 208 240 277 347 480 VMX-II-T5-48LC-3 52 0.43 0.25 0.22 0.19 0.15 0.11 VMX-11-T5-48LC-5 78 0.65 0.38 0.33 0.28 0.22 0.16 VMX-11-T5-48LC-7 106 0.88 0.51 0.44 0.38 0.31 0.22 VMX-11-T5-48LC-10 161 4 0.77 0.58 0.46 0.34 VMX-11-T5-64LC-3 70 0.58 0.34 29 0.2F 0.20 0.15 VMX-11-T5-64LC-5 107 0.89 0.51 0.45 0.39 0.31 0.22 VMX-11-T5-64LC-7 142 1.18 0.68 0.59 0.51 0.41 0.30 VMX-11-T5-64LC-10 218 1.82 1.05 0.91 0.79 0.63 0.45 VMX-11-T5-80LC-3 87 0.73 0.42 0.36 0.31 0.25 0.18 VMX-11-T5-80LC-5 132 1.10 0.63 0.55 0.48 0.38 0.28 VMX-11-T5-80LC-7 177 1.48 0.85 0.74 0.64 0.51 0.37 VMX-11-T5-80LC-10 272 2.27 1.31 1.13 0.98 0.78 0.57 VMX-11-T5-96LC-3 104 0.87 0.50 0.43 0.38 0.30 0.22 VMX-II-T5-96LC-5 157 1.31 1 0.75 0.65 1 0.57 0.45 1 0.33 VMX-11-T5-96LC-7 212 1.77 11.02 1 0.88 1 0.77 0.61 1 0.44 19645 Rancho Way -Rancho Dominguez, CA 90220 Phone: 310 512 6480 Fax 310 51.2 6486 www.visionairelighting.com 237 VMX-II LED Specifications Photometric Optical Summary 15.5” % w -M T1 T2 T3 Type 1 Type 2 Type 3 cc D—�„OU T4A T4 Type 4 Automotive Type 4 T5 T5W Type 5 Type 5 Wide � 7nU T5WR Type 5 Wide Round DNI -I •t -I Width: VMX-II 15.5” % w -M Height: VMX-u 4.0" + 10.75' 0.75 1.47 1.5 2.22 2.1 2.22 VMX-II-KM EPA DATA Degree of 9 00 100- 20° 30 400- 50° 604 709 800 90 ilt EPA 0.26 0.32 0.43 0.70 0.98 1.42 1.89 2.43 3.13 3.95 DNI -I •t -I Width: VMX-II 15.5” Depth: VMX-II 29" Height: VMX-u 4.0" Overall Height: vMx-ii 10.75' Weight: 49 LBS Drilling Template for (AM) and (SAM) V VISIONAIRE LIGHTING 238 Drilling Template for (UAM) VMX-II Options Universal Mast Arm Fitter UMAP - The Universal Mast Arm Fitter is a simple solution for retrofit applications where a fixture needs to mount to an existing pole, the UMAP is meant to be use to with knuckle mounts and also Mast Arm Fitters. The UMAP has a bolt slot ranging from 7" all the way down to 3.5". The UMAP also has a Round Pole Plate Adaptor (RPP) for mounting to round poles. Adjustable Louver Light Shield Egg Crate Light Shield Barn Door Light Shield 19645 Rancho Way Rancho Dominguez, CA 90220 Phone'. 310 512 6480 Fax 310 512 6486 www.visionairelighting.com 239 VMX-II LED Specifications Arm Mount (AM) The Arm Mount (AM) utilizes a 2 piece cleat system for easy installation, a terminal block is supplied as standard. A Round Pole Plate Adapter (RPP) is required for mounting to round poles. 3.24 Straight Arm Mount (SAM) The Straight Arm Mount (SAM) uses a 2 piece mounting system, a terminal block is supplied as standard. A Round Pole Plate Adapter (RPP) is required for mounting to round poles. = Ij 1. fI - I Universal Arm Mount (UAM) The Unviersal Arm Mount (UAM) is meant for retrofit Applications and has a drilling templat raning from 3" to 5.5". A Round Pole Plate Adapter (RPP) is required for mounting to round poles. V VISIONAIRE LIGHTING 240 VMX-11 Mast Arm Fitter (MAF) Mast Arm Fitter fits over a 1 5/8" - 2 3/8" tenon. Knuckle Mount (KM) An adjustable knuckle slip fits over a 2 3/8" Tenon, and allows for up to 90° degrees of vertical adjustment in 10° degree increments from horizontal, as well as full side to side adiustment. 28.48 15.28 Adjustable Wall Mount (AWM) Wall Mount -Adjustable up to 50° in 10° increments 19645 Rancho Way • Rancho Dominguez, CA 90220 • Phone: 310 512 6480 Fax 310 512 6486 www. visionairelig hting. com 241 VMX-II LED Specifications Twist lock Photocell & Receptacle - Dusk to dawn sensor. Round Pole Plate Adaptor (RPP) - Round Pole Plate Adaptor (RPP) to be used with round pole. Motion Sensor - *This option will require one FSIR 100 remote for programing. 242 The FSP -211 by Legrand is integrated into the VMX housing and provides multi-level control based on motion and/or daylight contribution. Lens Coverage Patterns: 1 Volts 360° lens, maximum coverage 48'; WSC-8 diameter from 8' height WSC-20 360° lens, maximum coverage 48'; Maximum diameter from 20' height WSC-40 360° lens, maximum coverage 100'; N/A diameter from 40' height T VISIONAIRE LIGHTING Photocell Receptacle and Shorting Cap Cast Wall Plate - Arm Mount Wall Plate is needed to wall mount the VMX-I1. Motion Sensor (for SAM, UAM, MAF, KM, AWM)- *This option will require one FSIR 100 remote for programing. * Motion Sensor for Standard Arm Mount (SAM), Universal Arm Mount (UAM), Mast Arm Fitter (MAF), Knuckle Mount (KM), Adjustable Wall Mount (AWM) Configuration shown Motion Sensor Default Settings High Mode 0 Volts Low Mode 1 Volts Time Delay 5 Minutes Cut Off 1 Hour Sensitivity Maximum Hold Off Set Point 4tt Candles N/A Ramp Up None Fade Down None Force Off Set Point With Occupied Disable House Shield - Provides solid back light cutoff UPMA The Universal Pole Mount Adaptor is ideal for retrofit applications with existing square poles. This adaptor is slotted to fit any existing drilling pattern, up to 6 Yz" bolt to bolt maximum. CLS The Back Side Cutoff Louver Shield will reduce light output 9 behind the fixture all of the li ht will be:'-�.focused in front of the VMX. RCLS The Right Side Cutoff Louver Shield will reduce light output on the right side of the fixture, all of the light be focused on the left side of the VMX. Not tr be used wifri t<'M VMX-II UPMA-R The Universal Pole Mount Adaptor )und is ideal for retrofit applications with existing round poles. This adaptor is slotted to fit any existing drilling pattern, up to 61/2" bolt to bolt maximum. i LCLS The Left Side Cutoff Louver Shield will reduce light output on the left side of the fixture, all of the light be focused on the right side of the VMX. /i- ��'� �--, .il,--,il�%i--''�-►ill ._ — Nam, � 196,15 Rarcno'hay Rancho Dominguez, CA 90220 - Phone'. 310 512 6480 Fax 310 512 6486 www.visionalrelighting.com 243 0 B m 0 o a , UPMA The Universal Pole Mount Adaptor is ideal for retrofit applications with existing square poles. This adaptor is slotted to fit any existing drilling pattern, up to 6 Yz" bolt to bolt maximum. CLS The Back Side Cutoff Louver Shield will reduce light output 9 behind the fixture all of the li ht will be:'-�.focused in front of the VMX. RCLS The Right Side Cutoff Louver Shield will reduce light output on the right side of the fixture, all of the light be focused on the left side of the VMX. Not tr be used wifri t<'M VMX-II UPMA-R The Universal Pole Mount Adaptor )und is ideal for retrofit applications with existing round poles. This adaptor is slotted to fit any existing drilling pattern, up to 61/2" bolt to bolt maximum. i LCLS The Left Side Cutoff Louver Shield will reduce light output on the left side of the fixture, all of the light be focused on the right side of the VMX. /i- ��'� �--, .il,--,il�%i--''�-►ill ._ — Nam, � 196,15 Rarcno'hay Rancho Dominguez, CA 90220 - Phone'. 310 512 6480 Fax 310 512 6486 www.visionalrelighting.com 243 VMX-ii LED Specifications V VISIONAIRE LIGHTING 244 VMX-11 - 3K Lumen Data #LED's mA Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR Watts 48 350 7311 6909 7243 6994 7321 7506 7333 7191 52 530 9808 9269 9717 9383 9822 10070 9838 9648 78 700 12786 12084 12668 12232 12805 13128 12826 12578 106 1050 17509 16547 17347 16750 17534 17977 17563 17223 161 350 9309 8798 9223 8906 9323 9558 9338 9158 70 64 530 13763 13007 13636 13167 13783 14131 '3806 13539 107 700 16888 15960 16732 16156 16912 17339 '6940 16612 142 1050 23222 21946 23007 22215 23255 23843 23293 22843 218 350 11512 10880 11406 11013 11529 11820 '547 11324 87 80 530 16640 15726 16486 15918 16664 17084 16691 16368 132 700 20813 19670 20621 19911 20844 21370 20878 20474 177 1050 29027 27433 28759 27769 29069 29803 29'7 28554 272 350 13714 12961 13588 13120 13734 14081 13757 13491 104 96 530 19516 18444 19336 18670 '9544 20038 19576 19198 57 700 24739 23380 24511 23667 ?477 25400 24815 24336 212 VMX-11 - 4K Lumen Data #LED's mA Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR Watts 350 769; 7273 7624 7362 7707 7901 7719 7627 52 48 530 10324 9757 10229 9876 10339 10600 10356 10232 78 700 13459 12720 13335 12876 13479 13819 1350' 13340 106 1050 18430 17418 153260 17631 18457 18923 18487 18267 161 350 9799 9261 9709 9375 9814 10061 9830 9713 70 64 530 14487 13692 14354 13860 14509 14875 14532 14359 107 700 17777 16800 17612 17006 17802 18252 17831 1.7619 142 1050 24444 23101 24218 23385 24479 25097 24519 242?7 218 350 12118 11452 12006 11593 12135 12442 12156 12010 87 60 530 17515 16553 17354 16756 17541 17984 17569 17360 132 700 21909 20705 21707 20959 2_1941 22495 21977 21715 177 1050 30555 28876 30273 29231 30599 31372 30649 30284 272 350 14436 13643 14303 13811 14457 14822 14481 14308 104 96 530 20543 19415 20354 19653 20573 21092 20607 20361 157 700 26041 24611 2,5801 24912 1 26079 26737 26122 25810 212 VMX-11- 5K Lumen Data #LED's mA Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR Watts 350 7384 6979 7316 7064 7395 7582 7407 7264 52 48 530 9907 9362 9815 9477 9921 10172 9937 9745 78 700 12915 1220E 12796 12356 12934 13261 12955 '2705 106 1050 17685 16714 17522 16919 17711 18158 17740 7397 161 64 350 9403 8887 9317 8996 9417 9655 9433 9250 70 530 13902 13138 13774 13300 13922 14274 `3945 13675 107 700 17058 16121 16901 16319 17083 17514 16780 142 1050 23456 22168 23240 22440 23490 24083 23529 23074 218 350 11628 10989 11521 11124 11645 11939 11664 11439 87 80 530 16808 15884 '6653 16079 16832 17257 16860 16534 132 700 21024 19869 20830 20112 21054 21586 21089 20681 177 1050 29320 27710 29050 28050 29363 30104 29411 28842 272 96 350 13853 13092 13725 13253 13873 14223 13896 13627 104 530 19713 18630 19531 18859 19742 20240 19774 19392 157 700 24989 23616 24758 23906 1 25025 25657 25066 24581 212 V VISIONAIRE LIGHTING 244 VMX-II 19645 Rancho Way - Rancho Dominguez, CA 90220 Phone'. 310 512 6480 Fax 310 512 6486 www.visonairelightling.com 245 VMX-II - 3K Lumen Per Watt Data #LED's mA Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR 350 141 133 139 134 141 144 141 `38 48 530 125 118 124 120 125 129 126 123 700 121 114 120 115 121 124 121 119 1050 109 103 108 10Z 109 112 109 107 64 350 133 126 132 127 133 137 133 131 530 129 _ 127 123 129 132 129 127 700 119 112 118 114 119 122 119 117 1050 107 101 106 102 107 109 107 105 80 350 133 125 131 127 133 136 133 130 530 126 119 125 121 126 130 127 124 700 118 111 117 112 118 121 118 116 1050 107 101 106 102 107 110 107 105 96 350 132 125 131 127 132 136 133 130 530 125 118 123 119 125 128 125 123 700 117 110 ! 61 112 117 120 1 1 7 115 VMX-II - 4K Lumen Per Watt Data #LED's mA Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR 350 148 140 147 142 148 152 148 47 48 530 132 125 131 126 132 135 132 31 700 127 120 126 121 127 130 127 126 1050 114 108 113 110 115 118 115 113 350 140 132 139 134 140 144 140 139 64 530 135 128 134 130 136 139 136 134 700 125 118 24 120 125 129 126 124 1050 112 106 111 107 112 115 112 111 350 140 132 138 133 140 143 140 138 80 530 133 126 132 127 133 136 133 132 700 124 117 123 118 124 127 124 123 1050 112 106 11' 108 ill 115 113 '11 96 350 139 132 138 133 139 143 140 138 530 131 124 130 125 '31 135 132 130 700 123 116 122 118 73 126 123 122 VMX-II - 5K Lumen Per Watt Data #LED's mA Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR 350 142 134 141 136 142 146 142 140 48 530 127 120 125 121 127 130 127 124 700 122 115 121 117 `22 125 122 120 1050 110 104 109 105 110 113 1'0 108 64 350 134 '2' 133 129 135 138 135 132 530 3C 1123 129 124 130 133 130 128 700 12' 114 119 115 120 123 121 118 1050 1^'8 102 '07 103 108 110 108 106 350 14 127 128 134 137 134 132 80 530 2- 121 _� 122 128 131 128 126 700 119 112 118 114 119 122 119 117 1050 108 102 107 103 108 111 108 1.06 96 350 134 126 132 128 134 137 134 131 530 126 119 125 '20 126 129 126 24 700 118 111 117 1 113 118 121 118 16 19645 Rancho Way - Rancho Dominguez, CA 90220 Phone'. 310 512 6480 Fax 310 512 6486 www.visonairelightling.com 245 VMX-II LED Specifications V VISIONAIRE LIGHTING 246 VMX-II - 3K BUG Data Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type T5WR LED's mA B U G B U G B U G B U G B U G B U G B U G B JUI G 350 2 0 2 2 C 2 1 0 2 2 0 2 1 0 1 3 0 1 3 0 2 3 1 0 1 2 530 3 0 3 2 0 3 1 0 2 2 0 2 2 0 1 3 0 2 3 0 2 4 0 2 48 700 3 0 3 3 0 3 2 0 2 2 0 3 2 02 3 0 2 4 0 2 4 0 2 1050 4 0 3 3 0 3 2 0 3 3 0 3 3 0 2 4 0 2 4 0 2 4 0 2 350 3 0 3 2 0 3 1 0 2 2 0 2 2 0 1 3 0 2 3 0 2 4 0 2 530 3 0 3 3 0 3 2 0 2 2 0 3 2 0 2 4 0 2 4 0 2 4 0 2 64 700 4 0 3 3 C 3 2 0 3 3 0 3 3 0 2 4 C 2 4 0 2 4 0 2 1050 4 0 4 3 0 4 3 0 3 3 0 3 3 0 2 4 0 2 5 0 3 5 0 3 350 3 0 3 2 0 3 2 0 2 2 0 2 2 0 1 3 0 2 4 0 2 4 0 2 530 4 0 3 3 0 3 2 0 3 3 0 3 3 0 2 4 0 2 4 0 2 4 0 2 80 700 4 0 4 3 0 4 3 0 3 3 0 3 3 0 2 4 0 2 5 0 3 5 0 3 1050 5 0 4 3 0 4 3 0 4 3 0 4 3 0 3 - 0 3 5 0 3 5 0 Al 350 3 0 3 3 0 3 2 0 2 2 0 3 2 0 2 4 0 2 4 0 2 4 0 2 96 530 4 0 4 3 0 3 2 0 3 3 0 3 3 0 2 4 0 2 4 0 2 5 0 3 700 4 0 4 3 0 4 3 0 4 3 C 4 3 0 2 4 2 5 0 3 5 0 3 VMX-II - 4K BUG Data LED's mA Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type T5WR 350 3 0 3 2 0 2 1 1 0 1 2 2 0 2 1 0 1 3 0 1 3 1 0 2 3 0 2 530 3 0 3 2 0 3 2 0 2 2 0 2 2 0 1 3 0 2 4 0 2 4 0 2 48 700 3 0 3 3 C 3 2 0 2 2 0 3 2 0 2 4 0 2 4 0 2 4 0 2 1050 4 0 3 3 0 3 2 0 3 3 0 3 3 0 2 4 0 2 4 0 2 5 0 3 350 3 0 3 2 0 3 1 0 2 2 0 2 2 0 1 3 0 2 3 0 2 4 0 2 530 3 0 3 3 0 3 2 0 2 3 0 3 2 0 2 4 0 2 4 0 2 4 0 2 64 700 4 0 3 3 0 3 2 0 3 3 0 3 3 0 2 4 0 2 4 0 2 4 0 2 1050 4 0 4 3 0 4 3 0 4 3 0 4 3 0 2 4 0 2 5 0 3 5 0 3 350 3 0 3 2 0 3 2 0 2 2 0 2 2 0 1 3 0 2 4 0 2 4 0 2 530 4 0 3 3 0 3 2 0 3 3 0 3 3 0 2 4 0 2 4 0 2 4 0 2 80 700 4 0 4 3 0 4 3 0 3 3 0 3 3 0 2 4 0 2 5 0 3 5 0 3 1050 5 0 4 3 0 5 3 0 4 3 0 4 3 0 3 5 0 3 5 0 4 5 0 4 350 3 0 3 3 0 3 2 0 2 2 0 3 2 0 2 4 0 2 4 0 2 4 0 2 96 530 4 0 4 3 0 4 3 0 3 3 0 3 3 0 2 4 0 2 5 0 3 5 0 3 700 4 0 4 3 0 4 3 0 4 3 0 4 3 0 3 5 0 3 5 0 3 5 0 3 VMX-II - 5K BUG Data LED's mA Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type T5WR 350 2 0 2 2 1 0 2 1 0 2 2 0 2 1 0 1 3 0 1 3 0 2 3 1 0 2 530 3 0 3 2 0 3 2 0 2 2 0 2 2 0 1 3 0 2 3 0 2 4 0 2 48 700 3 0 3 3 0 3 2 0 2 2 0 3 2 0 2 4 0 2 4 0 2 4 0 2 1050 4 0 3 3 0 3 2 0 3 3 0 3 3 0 2 4 0 2 4 0 2 4 0 2 350 3 0 3 2 0 3 1 0 2 2 0 1 2 2 0 1 3 0 2 3 0 2 4 0 2 530 3 0 3 3 0 3 2 0 2 2 0 3 2 0 2 4 0 1 2 4 0 2 4 0 2 64 700 4 0 3 3 0 3 2 0 3 3 0 3 3 0 1 2 4 0 2 4 0 2 4 0 2 1050 4 0 4 3 0 Al 3 0 3 3 0 3 3 0 1 2 4 0 2 5 0 3 5 0 3 350 3 0 3 2 0 3 2 0 2 2 0 2 2 0 1 3 0 2 4 0 2 4 0 2 530 4 0 3 3 C 3 2 0 3 3 0 3 3 0 2 4 0 2 4 0 2 4 0 2 80 700 4 0 4 3 0 4 3 0 3 3 0 3 3 0 2 n. 0 2 5 0 3 5 0 3 1050 5 0 4 3 0 4 3 0 4 3 0 3 0 3 5 0 4 5 0 4 350 3 0 3 3 03 2 0 2 4 0 9 4 0 2 4 0 9 96 530 4 0 4 3 #03t2 0 g30 3 3 0 2 4 0700 4 0 4 3 0 4 3 0 2 4 0 2 5 0 3 5 0 3 V VISIONAIRE LIGHTING 246 The subzones are individually rated on a scale from 0 to 5, going from lowest to highest luminous flex. The highest rating of a subzone is considered the overall rating for that zone, and these readings are compiled into the BUG lighting classification: for example, B3 U 1 G0. The tables below, which are based on the standards established by the IES, show the thresholds for each subzone. UH ii" Uplight 180° 100° 0 IFVH 90 INM 60° FM a, BL FL 300 �O 19645 Rancho W ay Rancno Dominguez, CA 90220 Phone: 310 512 6480 Fax 310 512 6486 www, visionairelig hting.com 247 VMX-II LED Specifications VVI SIONAIRE LIGHTING 248 VMX-II Cutoff Louver Shield - 3K Lumen Data *Not to be used with KM # of LEDs Current (mA) Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR Watts 350 4839 4388 4668 4666 5514 4472 3980 3932 52 530 6491 5886 6262 6260 7398 6000 5339 5275 78 48 700 8463 7674 8164 8162 9645 7822 6961 6878 106 1050 11589 10508 11180 1 11176 13207 10710 9531 9418 160 350 6162 5587 5944 5942 7022 5695 5068 5007 73 64 530 9109 8260 8788 8785 10382 8419 7492 7403 106 700 11178 10135 10783 10779 12739 10331 9193 9084 140 1050 15370 13937 14828 14822 17516 14205 12641 12491 218 350 7619 6909 7351 7348 8684 7042 6267 6192 88 80 530 11013 9987 10625 10621 12551 10179 9058 8950 131 700 13776 12492 13290 13285 15700 12732 11330 11195 176 1050 19212 17421 18535 18528 21895 17757 15801 15613 274 350 9077 8231 8757 8754 10345 8389 7466 7377 104 96 530 12917 11713 1 12462 12457 14721 11939 10624 10497 F 157 700 16374 14848 1 15797 15791 18661 15134 13467 13307 1 212 VMX-II Cutoff Louver Shield - 4K Lumen Data *Not to be used with KM # of LEDs Current (mA) Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type SWR Watts 350 .,-, 4619 4914 4912 5805 4707 4189 4139 52 530 6833 6196 6592 6590 7787 6315 5620 5553 78 48 700 8908 8078 8594 8591 10152 8233 7327 7240 106 1050 12198 11061 11768 11764 13902 11274 10033 9913 160 350 6486 5881 6257 6255 7392 5995 5334 5271 73 64 530 9589 8695 9251 9247 10928 8862 7887 7793 106 700 11766 10669 11351 11347 13409 10874 9677 9562 140 1050 16179 14670 15608 15602 18438 14953 13307 13148 218 350 8020 7273 7738 7735 9141 7413 6597 6518 88 80 530 11593 10512 11184 11180 13212 10715 9535 9421 131 700 14501 13149 13989 13984 16526 13402 11927 11784 176 1050 _ 18338 19510 1 19503 23048 18691 16633 16435 274 350 8664 9218 9215 10889 8831 7859 7765 104 96 530 �.._ ?2329 13117 13113 1 15496 12567 11183 11050 157 700 16628 1662.2 1 19643 15930 4176 14007 1 212 VMX-II Cutoff Louver Shield - 5K Lumen Data *Not to be used with KM # of LEDs Current (mA) Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR Watts 350 5197 4713 5014 5012 5923 4804 4275 4224 52 530 6973 6322 6727 6724 7946 6444 5735 5666 78 4$ 700 9090 8243 8770 8766 10360 8401 7476 7387 106 1050 12447 11287 12008 12004 14186 11504 10238 10116 160 350 6618 6001 6385 6383 7543 6117 5443 5379 73 64 530 9785 8872 9439 9436 11151 9043 8047 7952 106 700 12006 10887 11583 11578 13683 '11096 9875 9757 140 1050 16509 14970 15927 15921 18814 15258 13578 13416 218 350 8184 7421 7895 7893 9327 7564 6731 6651 88 80 530 11830 10727 11412 11408 13482 10933 9729 9614 131 700 14797 13417 14275 14270 16863 13676 12170 12025 176 1050 20636 '8712 19908 19901 23518 19073 16973 16770 274 350 9750 8841 9406 9403 11112 9011 8019 7924 1 104 96 530 13875 12581 13385 1 13380 15812 12823 11411 11275 1 157 700 17588 15948 16967 1 16%' 2004416255 14465 14293 1 212 VVI SIONAIRE LIGHTING 248 VMX-ii 8645 Rarcno'v'vay Rancho Dominguez, CA 90220 Phone: 310 51 2 6480 Fax 310 512 6486 www.visionairelighting.com 249 VMX-II Cutoff Louver Shield - 3K Lumen Per Watt Data *Not to be used with KM # of LEDs Current (ni Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR Watts 350 93 84 90 90 106 36 77 76 52 48 530 83 75 80 80 94 77 68 67 78 700 80 72 77 77 91 74 66 65 106 1050 72 66 70 70 83 67 60 59 160 350 85 77 1 82 82 96 78 70 69 73 64 530 86 78 83 83 98 79 71 70 106 700 80 72 77 77 91 74 66 65 140 1050 71 64 68 68 80 65 58 57 218 350 86 78 83 83 98 80 71 70 88 30 530 84 76 81 81 96 77 69 68 131 700 78 71 76 75 89 72 64 64 176 1050 70 64 68 68 80 65 58 57 274 350 88 79 84 84 100 8172 71 104 96 530 82 75 80 80 94 1 76 68 67 157 700 77 1 70 1 75 74 88 71 64 63 212 VMX-11 Cutoff Louver Shield - 4K Lumen Per Watt Data *Not to be used with KM # of LEDs Current (rnA) Type t Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR Watts 350 98 39 95 94 112 91 81 80 52 48 530 87 79 84 84 99 81 72 71 78 700 84 76 81 81 96 78 69 68 106 1050 76 69 1 74 74 87 70 1 63 62 160 350 89 81 86 86 101 82 73 72 73 64 530 90 82 87 87 103 33 74 73 106 700 84 76 31 81 96 78 69 68 140 1050 74 67 72 72 85 69 61 60 218 350 91 82 88 88 104 84 1 75 74 88 80 530 88 80 85 85 101 82 73 72 131 700 82 75 79 79 94 76 68 67 176 1050 74 67 71 71 84 68 61 60 274 350 92 84 89 89 105 85 76 75 1 104 96 530 37 79 84 84 99 80 71 157 700 81 74 78 78 93 75 66 212 VMX-II Cutoff Louver Shield - 5K Lumen Per Watt Data *Not to be used with KM # of LEDs Current (rnA) Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR Watts 350 100 91 96 96 114 92 82 81 52 48 530 89 81 86 86 101 82 73 12 78 700 86 78 83 83 98 79 71 70 106 1050 78 71 1 75 75 89 72 r34 63 160 350 91 82 88 88 104 84 75 74 73 64 530 92 84 89 89 105 85 76 75 106 700 86 78 83 83 98 79 71 70 140 1050 76 69 73 73 86 70 62 62 218 350 93 84 1 89 89 106 86 76 75 88 ao 530 90 82 87 87 103 83 74 73 131 700 84 76 81 81 96 78 69 68 176 1050 75 68 73 73 86 70 62 51 274 350 94 85 91 91 107 87 77 76 104 96 530 89 80 85 85 101 82 73 72 157 700 83 1 75 80 80 D5 1 77 1 68 67 212 8645 Rarcno'v'vay Rancho Dominguez, CA 90220 Phone: 310 51 2 6480 Fax 310 512 6486 www.visionairelighting.com 249 VMX-II LED Specifications %W'VISIONAIRE LIGHTING 250 VMX-II Cutoff Louver Shield - 3K BUG Data *Not to be used with KM # of LEDs Current (mA) Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR Watts B U G B U G B U G B U G B U G B U G B U G B U G 350 2 0 2 1 0 2 1 0 2 1 0 2 1 0 2 1 0 1 1 0 1 1 0 1 52 530 2 0 2 1 0 2 1 0 2 1 0 2 1 0 2 1 0 1 2 0 2 2 0 2 78 48 700 2 0 2 1 0 3 2 0 2 1 0 2 1 0 2 2 0 2 2 0 2 2 0 2 106 1050 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0-2- 3 0 3 160 350 2 0 2 1 0 2 1 0 2 1 0 2 1 0 2 0 1 2 0 2 2 0 2 73 530 3 0 3 1 0 3 2 0 2 2 0 3 1 0 2 2 0 2 2 0 2 2 0 2 106 04 700 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 2 0 2 2 0 2 140 1050 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 3 0 2 3 0 3 3 0 3 218 350 2 0 2 1 0 3 1 0 2 1 0 2 1 0 2 2 0 1 2 0 2 2 0 2 88 530 3 0 3 2 0 3 2 0 3 2 0 3 1 0 3 2 0 2 2 0 2 2 0 2 131 80 700 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 2 3 0 3 176 1050 3 0 4 2 0 4 3 0 3 3 0 4 2 0 3 3 0 3 3 0 3 3 0 3 274 350 3 0 3 1 0 3 2 0 2 2 1 0 2 2 0 2 2 0 2 2 0 2 104 96 530 3 0 3 2 0 3 2 0 3 2 t03 2 0 3 2 0 2 3 0 2 3 0 3 157 700 3 0 3_ 0 3 3 0 3 2 2 0 3 3 0 2 3 0 3 3 0 3 212 VMX-II Cutoff Louver Shield - 4K BUG Data *Not to be used with KM Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR # of LEDs Current (mA) Watts B U G B U G B U G B U G B U G B U G B U G B U G 350 2 0 2 1 0 2 1 0 2 1 0 2 1 0 2 1 0 1 1 0 1 1 0 1 52 530 2 0 2 1 0 2 1 0 2 1 0 2 1 0 2 2 0 1 2 0 2 2 0 2 78 48 700 3 0 3 1 0 3 2 0 2 2 0 3 1 0 2 2 0 2 2 0 2 2 0 2 106 1050 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 2 3 0 3 160 350 2 0 2 1 0 2 1 0 2 1 0 2 1 0 2 1 0 1 2 0 2 2 0 2 73 64 530 3 0 3 1 0 3 2 0 3 2 0 3 1 0 2 2 0 2 2 0 2 2 0 2 106 700 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 2 3 0 3 140 1050 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 30 2 3 0 3 3 0 3 218 350 2 0 2 1 0 3 1 0 2 1 0 2 1 0 2 2 0 2 2 0 2 2 0 2 88 530 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 2 3rO 3 131 80 700 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 2 3 3 176 1050 3 0 4 2 0 4 3 0 3 3 0 4 2 0 3 3 0 3 3 0 3 3 3 274 350 3 0 3 1 0 3 2 0 3 2 0 3 1 0 2 2 0 2 2 0 2 2 2 104 96 530 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 2 3 3 157 700 3 0 3 2 0 4 3 0 3 2 1 0 1 3 2 0 3 3 0 2 3 0 3 3 0 3 212 VMX-II Cutoff Louver Shield - 5K BUG Data *Not to be used with KM Type 1 Type 2 Type 3 Type 4 Type 4A Type 5 Type 5W Type 5WR # of LEDs Current (mA) Watts B U G B U G B U G B I U I G B U G B U G B U G B I U G 350 2 0 2 0 2 1 0 2 1 0 2 1 0 2 1 0 1 1 0 1 1 0 1 52 530 2 0 2 0 2 1 0 2 1 012 1 0 2 2 0 1 2 0 2 2 0 2 78 48 700 3 0 3 1 0 3 2 0 2 2 0 3 1 0 2 2 0 2 2 0 2 2 0 2 106 1050 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 2 3 0 3 160 350 2 0 2 1 0 2 1 0 2 1 0 2 1 0 2 1 0 1 2 0 2 2 0 2 73 530 3 0 3 0 3 2 0 3 2 0 3 1 0 3 2 0 2 2 0 2 2 0 2 106 64 700 3 0 3 2 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 2 3 0 3 140 1050 3 0 3 2 0 3 3 0 3 2 0 3 2 0 3 3 0 2 3 0 3 3 0 3 218 350 2 0 2 1 0 3 2 0 2 1 0j21 212 0 2 2 0 2 2 0 2 88 530 3 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 2 3 0 3 131 80700 3 0 3 2 0 3 2 0 3 2 0 3 2 0 2 3 0 3 3 0 3 176 1050 3 0 4 3 0 4 3 0 4 3 0 3 3 0 3 3 0 3 3 0 3 274 350 3 0 3 1 0 3 2 0 3 2 0 3 2 0 2 2 0 2 2 0 296 530 3 0 3 2 0 3 232 0 3 2 0 2 3 02 3 0 3700 3 0 3 2 0 4 333 0 3 3 0 2 3 0 3 3 0 3 212 %W'VISIONAIRE LIGHTING 250 VMX-II -Ins The subzones are individually rated on a scale from 0 to 5, going from lowest to highest luminous flex. The highest rating of a subzone is considered the overall rating for that zone, and these readings are compiled into the BUG lighting classification: for example, B3 U1 G0. The tables below, which are based on the standards established by the IES, show the thresholds for each subzone. UH 904,11-01M, FM awl 60°\\BM 6j Uptight 1800 AM 1000 :UL gOc UL FVH INA 60° FM a, BL FL 300 �O 19645 Rancho W ay Rancho Dominguez, CA 90220 Phone: 310 51 2 6480 Fax 310 512 6486 www.visionairelighting. com 251 Aria - !Nall Sconce QED I Project Name: I Catalog Number; (Type moww- ARS-1 ARS -2 Sue Intertek The Aria - Wall Sconce offers a blend of contemporary architectural shapes, superior mechanical features combined with high performance and low maintenance LED sources. The ARS -1 is a low -profile luminaire designed to integrate easily into any architectural environment. The ARS -2 offers stylish architectural detail adding an impacting design element to any type of contemporary building. Both styles are full -cutoff, Dark -Sky approved luminaires. Lens: Each LED is covered with an injection -molded acrylic lens that provides unique Type II, Type III and Type IV distribution patterns. Housing: Die cast aluminum, permanently sealed and spun aluminum tops feature a die cast, tool -less entry door frame with one-piece, extruded silicone gasket. A quick -mount bracket is supplied for ease of installation. ARS -1 1 20" 1 71/4" 1 10" 1 48 1 17 ARS -2 1 20" I 12% 1 10" 48 21 Finish: Durable Quali-Guard® textured thermoset polyester powder coat, oven - baked at a temperature of 400 °F to promote maximum adherence and finish hardness. Finish is guaranteed for five (5) years. Optics: Visionaire Lighting offers LEDs in Type II, III and IV distribution patterns. CRI values are 70. LEDs: The highest lumen output, LEDs are utilized in the ARS series. The optical system qualifies as IES full cutoff to restrict light trespass, glare and light pollution. Driver: The ARS is supplied with a choice of 350 or 530 mA high-performance LED drivers that accept 120 V through 480 V, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40 C operations. 10 kV surge protector supplied as standard. ARS -1 Type II (T2) # of LEDs ' 21 mA 350 3000K 'warn white 120-277 *Universal Wall Mount "Down light only Bronze (BZ) Button Type Photocell 'Specify voltage ® 21 LC ( ) (3) (3K) voltage (UNV) (WM) Black (PC120) (PC208) (PC240) (PC277) (BK) 24 (24LC) 530 (5) 4000K 'Neutral white 450 () White Vandal -Resistant Type T e III (4K) (WH) Hardware 'Tamper ARS -2 (� 42 Grey -proof latch screw (VRH) O (24LC) 5000K 8 (4j (GY Aria Conduit Box 48 (5Kwhite) Silver Metallic (ACB) (48LC) (SL) Motion Sensor Type Custom Color (MS) Te4) V LED Emergency ® Battery Pack '4, ,,- e � ` 4 Watt, 6300K LEDs provide at least 145 minutes' illumination "Eoe mA T", 2 ryve a Type 4 wan. during power outages. A 3.6 V DC Ncad battery wl push button lest switch. 350 2745 2929 2625 25 Rated 0 oC to 50 oC. Pair with: 21 - Only available in 24 or 48 LED's 530 3787 37M 3573 36 (EBPL) Mc 3137 3347 3000 26 24 530 530 4328 4231 6084 at `Consult factory 350 54M 5858 5258 50 42 530 7580 7405 7165 72 350 6274 66M 6009 52 8 530 8662 &163 8189 82 Aria Visit www.VisionaireLi htin com for up-to-the-minute chart information, including es not listed here. Area fixture. 9 9 P- 9 tYP " For 5K multiply values by 0.96. For 3K multiply values by 0.95 For more detailed information of mounting, wiring or installation instructions, pease consult factory mm It poles are not ordered Win futures, please specify moulting requirements. This document contains proprietary information of Visionaire Lighting LLC. Any use of this Information requires the written approval of Visionaire Lighting, LLC. In keeping with our TOM policy of continuous improvement, Visionaire reserves the right to change any specifications contained herein without prior notice. 146 aar Ko3 wz.-ZCZ(6L9) Daz6-zCZ(6l9) -Jul 'SluDIInsuoo alNO3H0 LZOE6 V0 X2iVdii0OW lolls va 'ow!a uos -a'r'a 3AV N0130NIHd 9"U N=Mp nue==s zsrz )IiIVd2100W-NOi3OW:ld la3r' W 6u)Aaung uoI ® ,al = ..l roaa a.ddv 31V0 NQUMS3a ON lDluewuDJlnu3.Buueem6u3 BNS _CLO ll°z-'.a-la 11SIHX3 SNOUICINO0 ONUSIX3 SNOISIA38 .lila 33LLL 133H5 .�L'SZL M,8{,i{,fiaN aar -c3 026-ZCZ(6L9) OOZ6-ZCZ(6L9) 'Oul 'quojIN6uoo -03NO3HC LZOE6 VO'>IHVd8OON w LZ6 rO 'oml0 uo5 'a'�'a B£L 3AV NO.L33NRld MEI a��a.v pueaas LeroL BwAaunS puol ® 'NMvaa o: _ .�, N2iVd2lOOW-N013�NRld 13708d N O.ddV aVC NOI1dIaOS30 '0N lo(uawuo3lnu3.6uuaaul6u3 6n1� LLOZ-lCtl�O 11BIHX3 SNOI110N00 `JNIISIX3 SNOISN3a _ a 311LL 133HS N .�L'SZL M,8{,i{,fiaN tens ra oa au3 ss�naev z an e ce �ocr +s m vofs ro aardaoow �" � b� kZOf6 VO `Nl/VdNOOW � xO SSW O.N 0> v t N013JH Nd 9tBf� ]N^nN .] ilJbJ 08nOwnard .. aftlb !, d Dao arse Diva c3urm ��' `3AV N0130NINd 9lBEL v R5uTw5 133HS 213/100 s °:gkk`'��Fkk�gg �Sw m 2 3 G a d ow � z — i 4a o � o K 2 W s °:gkk`'��Fkk�gg �Sw Obtl6 vy' QNtlNa3J uvH 60V aNt '¢A,H Naissm aanrna,e Nvs w. .,Ni swa„NiaN3 wane Iwoseas w0]:;M1Oia3,vH',n09r 9 0-I60c-6.6 131 r]HatldYoow ez r Nusm snv .uai,�rv�m sled arsv oi,ra a.NrM {roau lu noweara ,Ivl'3A7d ntlo N LLemas3o ` y,� _ i � "� '' . "e `fix: d� �: sTauoa {zoic d�'HaddaoowCN V N013JNIMd Mct Nb'ONIGME) 9SID98d e�aQ Y it $ _ Ilv l S� 2 a08SSS000000 0 00000 .1 IN NO os Ilv l S� IN Wn L 66 431 AZO 6 tl] "Matlaa00W �r`,rn 3 „aa 6 at ,,,, ., o. ;�oa o - L o ara ui.� ox o ava ` - enoao aysr o,ra a.urm ,e-TIRrU-795 was mea _ �' �MG.61 ._ V •• R • ...r �.x ,o•U � N tzocs va Havdaoow '3AV N0130N1i1d 9l8£l HaoMHlava co Q M _ e. > U O O1 Q Z � Z � O W'. l a o a a o —_ —_ --__ a c o 0 o a i a o 0 0 o a o e o e o W e o a a e o a o o d ii W a zo 0 0 0 o a o v o e o W 0 0 p:a } o m M IZOC6VO'N8vdaoow `3AV N0130NIdd 9l8fl NVIdaalvMWdOls y _ W Q G ti WI I 3 I W Z x Q Z I� W Z a Z z 31383NO3 H3 w `- a Q 3 0 i i w 410 Zf5 1- Ooflfi vJ OONvna3d Nv5nOJ-1® S' 131 tl001f ONZ On'9 ft 0 6 6 11 .2I 17 'Ntltldtl00n o Noi_Jr+aa o1eva Jn sn aeNn on v3„w 31BaB of i�`., •` - �a .era I' `° �° - t�N rye tic �c' IZOC6 V3'NNVd?IOOW '3AVN0133N1hfd9G9El _ I O _ - - _-- _. -_ _ - anoeo ovs'r` diva caHvm 'TD3RO97'7vu 1d5 \$ S'.� t+cvxo.� ND'ld N31VM W2/OlS U 9EYR9� I 1 z I� o W (E � X S u 3S>> AVMNIVM;� �b -wY o�t Z R Ii 1 LU 0 r ¢may I 3 yah CL 1 m W R y � m g Ss e s x a � > W � Y jEe. �� of 0 h ?! ti f2h wgm aa� as Q � d �2y 4 4 R I 1 z I� o W (E � u W AVMNIVM;� Ii 1 LU 0 r ¢may I 3 yah CL 1 �� of i2y f2h wgm aa� as U ILI OON lP1P) X331 01f I6 tl3 '00NtlUNtl33 Ntl6 ✓IOJ JMIOIH3ltla'lilOPtl A rvL 'MlP 91[P-lOt-61N 131 LUL'ti tl:l 'N` g o.ti-tce- - e -eye •Wre /P1 �5JIN1 �N NO3 NtivM1 Y UBGib tlU usnl WOE6 VJ `NMVd&OOPV ja co �b33 3l>bIJ W/IOWIbtlU 3i Nx 3rllr' anabs arstl au've� tlm T u �C° `3AV N0190NAId WOCt 4� U �6 ura elass3ai �":,xm: vwvoa NVid M31VM WHO1S Eci: I c eru' g aflJO S a ly Zt 173 d Q• E E a a= o.7 o 4 II 9 t) I 3 P - C CU Q £ Y F 1 I L y I�f �9 tgg� ta g 5� a�.�. o I l • ti,' lE�r RESOLUTION NO. 2021-657 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF MOORPARK, CALIFORNIA, RECOMMENDING TO THE CITY COUNCIL APPROVAL OF COMMERCIAL PLANNED DEVELOPMENT NO. 2020-01 AND CONDITIONAL USE PERMIT NO. 2020-04, TO ALLOW THE DEMOLITION AN EXISTING 2,300 SQUARE -FOOT BUILDING AND DEVELOP A 6,186 SQUARE - FOOT, SINGLE -STORY AUTO REPAIR SHOP AND ASSOCIATED SITE IMPROVEMENTS LOCATED AT 13816 PRINCETON AVENUE, ON THE APPLICATION OF ABDUL SALEHI WHEREAS, on August 5, 2020, an application for Commercial Planned Development No. 2020-01 and Conditional Use Permit No. 2020-04 was filed by Abdul Salehi, on behalf of Mir Rafiq, President of Rafiq Inc. for the demolition of an existing 2,300 square -foot building and the development of a new 6,186 square -foot, single -story auto repair shop and associated site improvements at 13816 Princeton Avenue; and WHEREAS, at a duly noticed public hearing on June 22, 2021, the Planning Commission considered Commercial Planned Development No. 2020-01 and Conditional Use Permit No. 2020-04, including the agenda report and any supplements thereto, and written public comment; opened the public hearing and took and considered public testimony both for and against the proposal; and WHEREAS, the Community Development Director has determined that this project is categorically exempt from the provisions of CEQA pursuant to Section 15332 (Class 32: In -fill Development Project) of the CEQA Guidelines, as outlined in the Agenda Report and that there is no substantial evidence that the project will have a significant effect on the environment. Therefore, no further environmental documentation is needed. NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF MOORPARK, DOES HEREBY RESOLVE AS FOLLOWS: SECTION 1. ENVIRONMENTAL DOCUMENTATION: The Planning Commission, based on its own independent analysis and judgment, concurs with the Community Development Director's determination that the project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA) pursuant to Section 15332 (Class 32: In -fill Development Project) of the CEQA Guidelines, as outlined in the Agenda Report. In addition, there is no substantial evidence that the project will have a significant effect on the environment in that the site has already been developed. No further environmental documentation is needed. SECTION 2 COMMERCIAL PLANNED DEVELOPMENT FINDINGS: Based upon the information set forth in the staff report(s), accompanying studies, and oral and written public testimony, the Planning Commission makes the following findings in accordance with City of Moorpark, Municipal Code Section 17.44.040: ATTACHMENT 6 Resolution No. 2021-657 Page 2 A. The site design, including structure location, size, height, setbacks, massing, scale, architectural style and colors, and landscaping, is consistent with the provisions of the general plan, any applicable specific plans, zoning ordinance, and any other applicable regulations. The Project is consistent with the applicable development standards outlined in the DTSP and the SP -D General Plan land use designation, the CPD zoning designation, and the Landscape Standards and Guidelines. B. The site design would not create negative impacts on or impair the utility of properties, structures or uses in the surrounding area. As proposed and conditioned, the Project site provides required parking, access improvements, site lighting, utility upgrades and landscape improvements necessary to serve the proposed use and prevent impacts to adjacent properties. The proposed conditions would ensure the proposed use would not negatively impact the surrounding area. Conditions require a lighting coverage plan to ensure adequate lighting controlled by motion sensors, a security system that is registered with the Police Department, application of graffiti resistant paint and coating on low building faces. C. The proposed uses are compatible with the existing and permitted uses in the surrounding area. The Project is compatible to similar nearby uses including adjacent automotive shops and a gas station. The Project site is also located along a portion of Princeton Avenue that transitions from retail commercial uses to industrial commercial uses. SECTION 3. CONDITIONAL USE PERMIT FINDINGS: Based upon the information set forth in the staff report(s), accompanying studies, and oral and written public testimony, the Planning Commission makes the following findings in accordance with City of Moorpark, Municipal Code Section 17.44.040: A. The proposed use is consistent with the provisions of the General Plan, Zoning Ordinance, and all applicable regulations as outlined in the Agenda Report. B. The proposed use, as conditioned, is compatible with both existing and permitted land uses in the surrounding area in that an auto shop conducting light service and repairs is consistent with existing commercial uses within DTSP area. C. The proposed use, as conditioned, is compatible with the scale, visual character, and design of surrounding properties in that the Project improvements and building design would provide architecture, landscaping, access, parking, and lighting elements consistent with the DTSP and Zoning Ordinance. D. The proposed use, as conditioned, would not be obnoxious or harmful, or impair the utility of neighboring property or uses in that conditions of approval have been added to ensure adequate lighting controlled by motion sensors, a security Resolution No. 2021-657 Page 3 system that is registered with the Police Department, application of graffiti resistant paint and coasting on low building faces, the operation of the business is limited to the hours of 7:00 a.m. and no later than 8:00 p.m. Monday through Sunday and all repair and maintenance of vehicles would occur within the service bays. E. The proposed use, as conditioned, would not be detrimental to the public health, safety, convenience, or welfare in that the auto shop operation consists of the light service and repair of commercial vehicles, such as brakes, oil changes, tires and shock sales and installation, and tune-ups. SECTION 4. PLANNING COMMISSION RECOMMENDATION: The Planning Commission recommends to the City Council approval of Commercial Planned Development No. 2020-01 and Conditional Use Permit No. 2020-04 subject to the Standard and Special Conditions of Approval found in Exhibit A attached. SECTION 5. Filing of Resolution: The Community Development Director shall cause a certified resolution to be filed in the book of original resolutions. The action of the foregoing direction was approved by the following vote: AYES: NOES: ABSTAIN: ABSENT: PASSED, AND ADOPTED this 22nd day of June, 2021. Kipp Landis Chair Douglas Spondello, AICP Interim Community Development Director Exhibit A — Standard and Special Conditions of Approval Resolution No. 2021-657 Page 4 EXHIBIT A CONDITIONS OF APPROVAL FOR COMMERCIAL PLANNED DEVELOPMENT PERMINT NO. 2021-01 AND CONDITIONAL USE PERMIT NO. 2021-04 STANDARD CONDITIONS OF APPROVAL FOR SUBDIVISION AND PLANNED DEVELOPMENTS The applicant shall comply with Standard Conditions of Approval as adopted by City Council Resolution No. 2009-2799. The standard conditions identified below are those conditions that are applicable to the project. 1. Within thirty (30) calendar days of approval of this entitlement, the applicant shall sign and return to the Planning Division an Affidavit of Agreement and Notice of Entitlement Permit Conditions of Approval, indicating that the applicant has read and agrees to meet all Conditions of Approval of this entitlement. The Affidavit of Agreement/Notice shall include a legal description of the subject property and have the appropriate notary acknowledgement suitable for recordation. 4. This planned development permit expires one (1) year from the date of its approval unless the use has been inaugurated by issuance of a building permit for construction. The Community Development Director may, at his/her discretion, grant up to two (2) additional one-year extensions for use inauguration of the development permit if there have been no changes in the adjacent areas and if the applicant can document that he/she has diligently worked towards use inauguration during the initial period of time. The request for extension of this planned development permit must be made in writing, at least thirty (30) days prior to the expiration date of the permit and must be accompanied by applicable entitlement processing deposits. 5. The Conditions of Approval of this entitlement and all provisions of the Subdivision Map Act, City of Moorpark Municipal Code and adopted City policies at the time of the entitlement approval, supersede all conflicting notations, specifications, dimensions, typical sections and the like which may be shown on said Map and/or plans or on the entitlement application. This language shall be added as a notation to the Final Map and/or to the final plans for the planned development. 6. Conditions of this entitlement may not be interpreted as permitting or requiring any violation of law or any unlawful rules or regulations or orders of an authorized governmental agency. 7. Should continued compliance with these Conditions of Approval not be met, the Community Development Director may modify the conditions in accordance with Municipal Code Section 17.44.100 and sections amendatory or supplementary thereto, declare the project to be out of compliance, or the Director may declare, for some other just cause, the project to be a public nuisance. The applicant shall Resolution No. 2021-657 Page 5 be liable to the City for any and all costs and expenses to the City involved in thereafter abating the nuisance and in obtaining compliance with the Conditions of Approval or applicable codes. If the applicant fails to pay all City costs related to this action, the City may enact special assessment proceedings against the parcel of land upon which the nuisance existed (Municipal Code Section 1.12.170). 9. If any archeological or historical finds are uncovered during grading or excavation operations, all grading or excavation shall immediately cease in the immediate area and the find must be left untouched. The applicant, in consultation with the project paleontologist or archeologist, shall assure the preservation of the site and immediately contact the Community Development Director by phone, in writing by email or hand delivered correspondence informing the Director of the find. In the absence of the Director, the applicant shall so inform the City Manager. The applicant shall be required to obtain the services of a qualified paleontologist or archeologist, whichever is appropriate to recommend disposition of the site. The paleontologist or archeologist selected must be approved in writing by the Community Development Director. The applicant shall pay for all costs associated with the investigation and disposition of the find. 10. Paleontological Mitigation Plan: Prior to issuance of a Zoning Clearance for a grading permit, a paleontological mitigation plan outlining procedure for paleontological data recovery must be prepared and submitted to the Community Development Director for review and approval. The development and implementation of this Plan must include consultations with the Applicant's engineering geologist as well as a requirement that the curation of all specimens recovered under any scenario will be through the Los Angeles County Museum of Natural History (LACMNH). All specimens become the property of the City of Moorpark unless the City chooses otherwise. If the City accepts ownership, the curation location may be revised. The monitoring and data recovery should include periodic inspections of excavations to recover exposed fossil materials. The cost of this data recovery is limited to the discovery of a reasonable sample of available material. The interpretation of reasonableness rests with the Community Development Director. 11. The applicant shall defend, indemnify and hold harmless the City and its agents, officers and employees from any claim, action or proceeding against the City or its agents, officers or employees to attack, set aside, void, or annul any approval by the City or any of its agencies, departments, commissions, agents, officers, or employees concerning this entitlement approval, which claim, action or proceeding is brought within the time period provided therefore in Government Code Section 66499.37 or other sections of state law as applicable and any provision amendatory or supplementary thereto. The City will promptly notify the applicant of any such claim, action or proceeding, and, if the City should fail to do so or should fail to cooperate fully in the defense, the applicant shall not thereafter be responsible to defend, indemnify and hold harmless the City or its agents, officers, and employees pursuant to this condition. Resolution No. 2021-657 Page 6 a. The City may, within its unlimited discretion, participate in the defense of any such claim, action or proceeding if both of the following occur: i. The City bears its own attorney fees and costs; ii. The City defends the claim, action or proceeding in good faith. b. The applicant shall not be required to pay or perform any settlement of such claim, action or proceeding unless the settlement is approved by the applicant. The applicant's obligations under this condition shall apply regardless of whether a Final Map is ultimately recorded with respect to the subdivision or a building permit is issued pursuant to the planned development permit. 12. If any of the conditions or limitations of this approval are held to be invalid, that holding does not invalidate any of the remaining conditions or limitations set forth. 13. All facilities and uses, other than those specifically requested in the application and approval and those accessory uses allowed by the Municipal Code, are prohibited unless otherwise permitted through application for Modification consistent with the requirements of the zone and any other adopted ordinances, specific plans, landscape guidelines, or design guidelines. FEES 15. Entitlement Processing: Prior to the approval of any Zoning Clearance for this entitlement the applicant shall submit to the Community Development Department all outstanding entitlement case processing fees, including all applicable City legal service fees. This payment must be made within sixty (60) calendar days after the approval of this entitlement. 16. Condition Compliance: Prior to the issuance of any Zoning Clearance, building permit, grading permit, or advanced grading permit, the applicant shall submit to the Community Development Department the Condition Compliance review deposit. 17. Capital Improvements and Facilities and Processing: Prior to the issuance of any Zoning Clearance, the applicant shall submit to the Community Development Department, capital improvement, development, and processing fees at the current rate then in effect. Said fees include but are not limited to building and public improvement plan checks and permits. Unless specifically exempted by City Council, the applicant is subject to all fees imposed by the City as of the issuance of the first permit for construction and such future fees imposed as Resolution No. 2021-657 Page 7 determined by City in its sole discretion so long as said fee is imposed on similarly situated properties. 18. Parks: Prior to issuance of Zoning Clearance for a building permit, the applicant shall submit to the Parks, Recreation and Community Services Department fees in accordance with the Moorpark Municipal Code and to the satisfaction of the Parks, Recreation and Community Services Director. 19. Tree and Landscape: Concurrently with the issuance of a building permit, the Tree and Landscape Fee must be paid to the Building and Safety Division in accordance with City Council adopted Tree and Landscape Fee requirements in effect at the time of building permit application. 20. Fire Protection Facilities: Concurrently with the issuance of a building permit, current Fire Protection Facilities Fees must be paid to the Building and Safety Division in accordance with City Council adopted Fire Protection Facilities Fee requirements in effect at the time of building permit application. 21. Library Facilities: Concurrently with the issuance of a building permit, the Library Facilities Fee must be paid to the Building and Safety Division in accordance with City Council adopted Library Facilities Fee requirements in effect at the time of building permit application. 22. Police Facilities: Concurrently with the issuance of a building permit, the Police Facilities Fee must be paid to the Building and Safety Division in accordance with City Council adopted Police Facilities Fee requirements in effect at the time of building permit application. 23. Traffic Systems Management: Concurrently with the issuance of a Zoning Clearance for each building permit, the applicant shall submit to the Community Development Department the established Moorpark Traffic Systems Management (TSM) Fee for the approved development consistent with adopted City policy for calculating such fee. 25. Citywide Traffic: Concurrently with the issuance of a Zoning Clearance for each building permit, the applicant shall submit to the Community Development Department the Citywide Traffic Fee. The fee shall be calculated per dwelling unit for residential projects, or by use for commercial and industrial projects, based upon the effective date of approval of the entitlement consistent with adopted City policy for calculating such fee. The fee will be paid at the time of building permit issuance. 26. Area of Contribution: Concurrently with the issuance of a Zoning Clearance for each building permit, the applicant shall pay to the Community Development Department the Area of Contribution (AOC) Fee for the area in which the project Resolution No. 2021-657 Page 8 is located. The fee shall be paid in accordance with City Council adopted AOC fee requirements in effect at the time of building permit application. 27. Street Lighting Energy Costs: Prior to recordation of Final Map, or issuance of a building permit, whichever occurs first the applicant shall pay to the Community Development Department all energy costs associated with public street lighting for a period of one year from the acceptance of the street improvements in an amount satisfactory to the City Engineer and Public Works Director. 28. Schools: Prior to issuance of building permits for each building, the applicant shall provide written proof to the Community Development Department that all legally mandated school impact fees applicable at the time of issuance of a building permit have been paid to the Moorpark Unified School District. 29. Art in Public Places: Prior to or concurrently with the issuance of a Zoning Clearance for building permit, the applicant shall contribute to the Art in Public Places Fund in accordance with Municipal Code Chapter 17.50 and sections amendatory or supplementary thereto. Contribution is to be submitted to the Community Development Department. If the applicant is required to provide a public art project on or off-site in lieu of contributing to the Art in Public Places Fund, the artwork must have a value corresponding to, or greater than, the contribution, and must be approved, constructed, and maintained for the life of the project in accordance with the applicable provision of the Moorpark Municipal Code. 30. Electronic Conversion: In accordance with City policy, the applicant shall submit to the Community Development Department, City Engineer and Public Works Director and the Building and Safety Division the City's electronic image conversion fee for entitlement/condition compliance documents; Final Map/ engineering improvement plans/permit documents; and building plans/permit documents, respectively. 32. Crossing Guard: Prior to recordation of Final Map or prior to the issuance of a building permit, whichever occurs first, the applicant shall pay to the Community Development Department an amount to cover the costs associated with a crossing guard for five years at the then current rate, plus the pro -rata cost of direct supervision of the crossing guard location and staff s administrative costs (calculated at fifteen percent (15%) of the above costs). This applies to residential project of ten (10) or more units and commercial project of greater than 5,000 square feet. 33. Storm Drain Discharge Maintenance Fee: Prior to or concurrently with the issuance of a Zoning Clearance for building permit, the applicant shall pay to the Community Development Department the citywide Storm Drain Discharge Resolution No. 2021-657 Page 9 Maintenance Fee in accordance with City Council adopted Storm Drain Discharge Maintenance Fee requirements in effect at the time of building permit application. PLANNING DIVISION STANDARD CONDITIONS 42. For all flat roofed portions of buildings, a minimum eighteen -inch (18") parapet wall above the highest point of the flat roof must be provided on all sides. 43. Skylights are prohibited unless approved through the Planned Development Permit process or as a Modification to the Planned Development Permit. 44. The use of highly -reflective glass or highly reflective film applied to glass is not allowed on any structures. Highly -reflective glass is defined as glass having a visible light reflectance (VLR) rating of twenty (20) percent or greater. The use of darkly -tinted glass is only allowed in industrial zones. Darkly -tinted glass is defined as glass with a visible light transmittance (VLT) rating of fifty (50) percent or less. The use of low -emissivity (Low -E) glass is encouraged, but it must meet reflectance and transmittance requirements as noted above. The applicant shall provide a sample of the glass to be used, along with information on the VLR and VLT for review and approval by the Community Development Director prior to the issuance of building permits. 45. Exterior downspouts are not permitted unless designed as an integral part of the overall architecture and approved by the City as part of the planned development permit. 46. Mechanical equipment for the operation of the building must be ground -mounted and screened to the satisfaction of the Community Development Director. The Community Development Director may approve roof -mounted equipment, in which case, all parts of the roof mounted equipment (such as vents, stacks, blowers, air conditioning equipment, etc.) must be below the lowest parapet on the roof; and must be painted the same color as the roofing material. No piping, roof ladders, vents, exterior drains and scuppers or any other exposed equipment may be visible on the roof. 47. Roof -mounted equipment and other noise generation sources on-site must be attenuated to 45 decibels (dBA) or to the ambient noise level at the property line measured at the time of the occupancy, whichever is greater. Prior to the issuance of a Zoning Clearance for initial occupancy or any subsequent occupancy, the Community Development Director may request the submittal of a noise study for review and approval. The noise study would need to show that the current project attenuates all on-site noise generation sources to the required level or provide recommendations as to how the project could be modified to comply. The noise study must be prepared by a licensed acoustical engineer in accordance with accepted engineering standards. Resolution No. 2021-657 Page 10 48. Any outdoor ground level equipment, facilities or storage areas including, but not limited to loading docks, trash enclosures, cooling towers, generators, must be architecturally screened from view with masonry wall and/or landscaping as determined by the Community Development Director. 49. A utility room with common access to house all meters and the roof access ladder must be provided unless an alternative is approved by the Community Development Director. 50. No exterior roof access ladders are permitted. 52. Parking areas must be developed and maintained in accordance with the requirements of the Moorpark Municipal Code. All parking space and loading bay striping must be maintained so that it remains clearly visible during the life of the development. 53. Prior to any re -striping of the parking area, a Zoning Clearance is required. All disabled parking spaces and paths of travel must be re -striped and maintained in their original approved locations unless new locations are approved by the Community Development Director. 54. All parking areas must be surfaced with asphalt, concrete, or other surface acceptable to the Community Development Director, City Engineer and Public Works Director, and must include adequate provisions for drainage, National Pollution Discharge Elimination System (NPDES) compliance, striping and appropriate wheel blocks, curbs, or posts in parking areas adjacent to landscaped areas. All parking, loading and common areas must be maintained at all times to ensure safe access and use by employees, public agencies and service vehicles. 55. The Building Plans must be in substantial conformance to the plans approved under this entitlement and must specifically include the following: a. Transformers and cross connection water control devices (subject to approval by Ventura County Waterworks District No. 1), screened from street view with a masonry wall and/or landscaping as determined by the Community Development Director. b. Bicycle racks or storage facilities, in quantities as required by the Community Development Director and other City staff and in accordance with the Municipal Code. c. Required loading areas with 45 -foot turning radii for loading zones consistent with the AASHO WB -50 design vehicle and as required by the Community Development Director, City Engineer and Public Works Director. If drains from Resolution No. 2021-657 Page 11 the loading area are connected to the sewer system, they are subject to the approval of Ventura County Waterworks District No. 1. d. Final exterior building materials and paint colors consistent with the approved plans under this permit. Any changes to the building materials and paint colors are subject to the review and approval of the Community Development Director. e. Identification of coating or rust -inhibitive paint for all exterior metal building surfaces to prevent corrosion and release of metal contaminants into the storm drain system. f. Trash disposal and recycling areas in locations which will not interfere with circulation, parking, or access to the building. Exterior trash areas and recycling bins must use impermeable pavement and be designed to have a cover and so that no other area drains into it. The trash areas and recycling bins must be depicted on the final construction plans, the size of which must be approved by the Community Development Director, City Engineer and Public Works Director and the City's Solid Waste Management staff. When deemed appropriate, drains from the disposal and recycling areas must be connected to the sewer system and subject to the approval of Ventura County Waterworks District No. 1. Review and approval shall be accomplished prior to the issuance of a Zoning Clearance for building permit. 56. Prior to issuance of a Zoning Clearance for final building permit (occupancy), the applicant shall install U.S. Postal Service approved mailboxes in accordance with the requirements of the local Postmaster and to the satisfaction of the City Engineer and Public Works Director. 57. Any expansion, alteration or change in architectural elements requires prior approval of the Community Development Director. Those changes in architectural elements that the Director determines would visible from abutting street(s) may only be allowed, if, in the judgment of the Community Development Director such change is compatible with the surrounding area. Any approval granted by the Director must be consistent with the approved Design Guidelines (if any) for the planned development and applicable Zoning Code requirements. A Permit Modification application may be required as determined by the Community Development Director. OPERATIONAL REQUIREMENTS 62. Loading and unloading operations are allowed only between the hours of 6:00 a.m. and 10:00 p.m. unless additional hours are approved by the City Council. More restrictive hours for loading and unloading may be imposed by the Community Development Director if there are noise and other issues that make the loading and unloading incompatible with the adjacent residential uses. There shall be no idling of trucks while loading or unloading. Resolution No. 2021-657 Page 12 63. All uses and activities must be conducted inside the building(s) unless otherwise authorized in writing by the Community Development Director consistent with applicable Zoning Code provisions. 64. Prior to the issuance of a Zoning Clearance for any use which requires handling of hazardous or potentially hazardous materials, the applicant shall provide proof that he/she has obtained the necessary permits from Ventura County Environmental Health Division. Should the Community Development Director determine that a compatibility study is required; the applicant shall apply for a Permit Modification to the entitlement. 65. The applicant agrees not to protest the formation of an underground Utility Assessment District. 66. The continued maintenance of the subject site and facilities is subject to periodic inspection by the City. The Applicant and his/her successors, heirs, and assigns are required to remedy any defects in ground or building maintenance, as indicated by the City within five (5) working days from written notification. 67. No noxious odors may be generated from any use on the subject site. 68. The applicant and his/her successors, heirs, and assigns must remove any graffiti within seventy-two (72) hours from written notification by the City of Moorpark. All such graffiti removal must be accomplished to the satisfaction of the Community Development Director. 69. Prior to the issuance of a Zoning Clearance for tenant occupancy, the prospective tenant shall obtain a Business Registration Permit from the City of Moorpark. All contractors doing work in Moorpark shall have or obtain a current Business Registration Permit. 70. Prior to or concurrently with the issuance of a Zoning Clearance for occupancy of any of the buildings, the applicant shall request that the City Council approve a resolution to enforce California Vehicle Codes (CVC) on the subject property as permitted by the CVC. 72. Prior to issuance of Zoning Clearance for the first building permit, the applicant shall submit a Waste Reduction and Recycling Plan to the City's Solid Waste Management staff and the Community Development Director for review and approval. The Plan must include a designated building manager, who is responsible for initiating on-site waste materials recycling programs, including acquiring storage bins for the separation of recyclable materials and coordination and maintenance of a curbside pickup schedule. Resolution No. 2021-657 Page 13 73. The building manager or designee shall be required to conduct a routine on-site waste management education program for educating and alerting employees and/or residents to any new developments or requirements for solid waste management. This condition is to be coordinated through the City's Solid Waste Management staff. LANDSCAPING, LIGHTING AND MAINTENANCE REQUIREMENTS 75. Prior to the issuance of a Zoning Clearance for building permits, the applicant shall submit to the Community Development Director for review and approval, with the required deposit, three full sets of Landscaping and Irrigation Plans prepared by a licensed landscape architect and drawn on a plan that reflects final grading configuration, in conformance with the City of Moorpark Landscape Standards and Guidelines, policies and NPDES requirements; including, but not limited to, all specifications and details and a maintenance plan. Fences and walls must be shown on the Landscape and Irrigation Plans, including connection, at the applicant's expense, of property line walls with existing fences and or walls on any adjacent residential, commercial, or industrial properties. The plan must demonstrate proper vehicle sight distances subject to the review of the City Engineer and Public Works Director and in accordance with the Zoning Code, and encompass all required planting areas consistent with these Conditions of Approval. Review by the City's Landscape Architect Consultant and City Engineer and Public Works Director, and approval by the Community Development Director prior to issuance of a Zoning Clearance for building permit, is required. 76. The landscape plan must incorporate specimen size trees and other substantial features subject to the review and approval of the Community Development Director. Prior to the issuance of a grading permit, a tree survey must be prepared to determine the valuation of the mature trees to be removed. Enhanced replacement landscaping of equal or greater value, as determined by the Community Development Director, must be installed in accordance with the current applicable provisions of the Moorpark Municipal Code. 79. Prior to or concurrently with the submittal of the landscape and irrigation plan, a lighting plan, along with required deposit, must be submitted to the Community Development Director for review and approval. The lighting plan, prepared by an electrical engineer registered in the State of California, must be in conformance with the Moorpark Municipal Code. 80. Landscape plans submitted at the time of entitlement review are conceptual only. Entitlement approval does not include approval of the specific plant species on the conceptual landscape plans unless indicated in the Special Conditions of Approval. Detailed landscaping plans are subject to review and approval by the Community Development Director for compliance with the City's Landscape Standards and Guidelines. Resolution No. 2021-657 Page 14 82. Unless otherwise stipulated in the Special Conditions of Approval, the applicant shall be responsible for the maintenance of any and all parkway landscaping constructed as a requirement of the project, whether said parkway landscaping is within the street right-of-way or outside of the street right-of-way. Any parkway landscaping outside of the street right-of-way must be within a landscape maintenance district. 84. Tree pruning, consisting of trimming to limit the height and/or width of tree canopy and resulting in a reduction of required shade coverage for the parking lot area, is prohibited by Section 17.32.070 of the Moorpark Municipal Code and will be considered a violation of the Conditions of Approval. Tree trimming for the purposes of maintaining the health of trees is permitted with prior approval of the Community Development Director and City's designated arborist. 85. When available, use of reclaimed water is required for landscape areas subject to the approval of the Community Development Director, the City Engineer and Public Works Director and Ventura County Waterworks District No. 1. 86. Landscaped areas must be designed with efficient irrigation to reduce runoff and promote surface filtration and minimize the use of fertilizers and pesticides, which can contribute to urban runoff pollution. Parking and associated drive areas with five (5) or more spaces shall be designed to minimize degradation of storm water quality. Best Management Practice landscaped areas for infiltration and biological remediation or approved equals, must be installed to intercept and effectively prohibit pollutants from discharging to the storm drain system. The design must be submitted to the Community Development Director and City Engineer and Public Works Director for review and approval prior to the issuance of a building permit. 87. All landscaping must be maintained in a healthy and thriving condition, free of weeds, litter, and debris. 88. Prior to the issuance of Zoning Clearance for occupancy, all fences/walls along lot boundaries must be in place, unless an alternative schedule is approved by the Community Development Director. PUBLIC WORKS ENGINEERING STANDARD CONDITIONS 90. Grading, drainage and improvement plans and supporting reports and calculations must be prepared in accordance with the latest California Building Code as adopted by the City of Moorpark and in conformance with the latest "Land Development Manual" and "Road Standards" as promulgated by Ventura County; "Hydrology Manual" and "Design Manual" as promulgated by Ventura County Watershed Protection District; "Standard Specifications for Public Works Resolution No. 2021-657 Page 15 Construction" as published by BNI (except for signs, traffic signals and appurtenances thereto which must conform to the provisions of Chapter 56 for signs and Chapter 86 for traffic signals, and appurtenances thereto, of the "Standard Specifications," most recent edition, including revisions and errata thereto, as published by the State of California Department of Transportation). 91. Grading, drainage and improvement plans and supporting reports and calculations must be prepared in accordance with the most recently approved "Engineering Policies and Standards" of the City of Moorpark, and "Policy of Geometric Design of Highways and Streets," most recent edition, as published by the American Association of State Highway and Transportation Officials. In the case of conflict between the standards, specifications and design manuals listed herein and above, the criteria that provide the higher level of quality and safety prevail as determined by the City Engineer and Public Works Director. Any standard specification or design criteria that conflicts with a Standard or Special Condition of Approval of this project must be modified to conform with the Standard or Special Condition to the satisfaction of the City Engineer and Public Works Director. 92. Engineering plans must be submitted on standard City title block sheets of 24 - inch by 36 -inch to a standard engineering scale representative of sufficient plan clarity and workmanship. 94. If any hazardous waste or material is encountered during the construction of this project, all work must be immediately stopped and the Ventura County Environmental Health Department, the Ventura County Fire Protection District, the Moorpark Police Department, and the Moorpark City Engineer and Public Works Director must be notified immediately. Work may not proceed until clearance has been issued by all of these agencies. 95. The applicant and/or property owner shall provide verification to the City Engineer and Public Works Director that all on-site storm drains have been cleaned at least twice a year, once immediately prior to October 1st (the rainy season) and once in January. Additional cleaning may be required by the City Engineer and Public Works Director depending upon site and weather conditions. 96. All paved surfaces; including, but not limited to, the parking area and aisles, drive- through lanes, on-site walkways must be maintained free of litter, debris, and dirt. Walkways, parking areas and aisles and drive-through lanes must be swept, washed, or vacuumed regularly. When swept or washed, litter, debris and dirt must be trapped and collected to prevent entry to the storm drain system in accordance with NPDES requirements. 97. Prior to improvement plan approval, the applicant shall obtain the written approval on approved site plan exhibit sheets for the location of fire hydrants by the Ventura Resolution No. 2021-657 Page 16 County Fire Prevention Division. Water and Sewer improvements plans must be submitted to Ventura County Waterworks District No. 1 for approval. 98. Prior to any work being conducted within any State, County, or City right -of- way, the applicant shall obtain all necessary encroachment permits from the appropriate agencies and provide copies of these approved permits and the plans associated with the permits to the City Engineer and Public Works Director. 99. Reactive organic compounds, Nitrogen oxides (ozone/smog precursor), and particulate matter (aerosols/dust) generated during construction operations must be minimized in accordance with the City of Moorpark standards and the standards of the Ventura County Air Pollution Control District (APCD). When an air pollution Health Advisory has been issued, construction equipment operations (including but not limited to grading, excavating, earthmoving, trenching, material hauling, and roadway construction) and related activities must cease in order to minimize associated air pollutant emissions. 100. The applicant shall comply with Chapters 9.28, 10.04, 12.24, and 17.53 of the Moorpark Municipal Code and any provision amendatory or supplementary thereto, as a standard requirement for construction noise reduction. 101. The applicant shall utilize all prudent and reasonable measures (including installation of a 6 -foot -high chain link fence around the construction site(s) and/or provision of a full-time licensed security guard) to prevent unauthorized persons from entering the work site at any time and to protect the public from accidents and injury. 102. The applicant shall post, in a conspicuous location, the construction hour limitations and make each construction trade aware of the construction hour limitations. GRADING 103. All grading and drainage plans must be prepared by a qualified Professional Civil Engineer currently registered and in good standing in the State of California and are subject to review by the City Engineer and Public Works Director. Prior to or concurrently with the submittal of a grading plan the applicant shall submit a soils (geotechnical) report. 105. Prior to the issuance of a grading permit or Final Map approval, whichever comes first, the applicant shall post sufficient surety with the City, in a form acceptable to the City Engineer and Public Works Director, guaranteeing completion of all onsite and offsite improvements required by these Conditions of Approval and/or the Municipal Code including, but not limited to grading, street improvements, storm drain improvements, temporary and permanent Best Management Practice Resolution No. 2021-657 Page 17 (BMP) for the control of non -point water discharges, landscaping, fencing, and bridges. Grading and improvements must be designed, bonded, and constructed as a single project. 106. Prior to the issuance of a grading permit or Final Map approval, whichever occurs first, the applicant shall provide written proof to the City Engineer and Public Works Director that any and all wells that may exist or have existed within the project have been properly sealed, destroyed or abandoned per Ventura County Ordinance No. 2372 or Ordinance No. 3991 and per California Department of Conservation, Division of Oil, Gas, and Geothermal Resources requirements. 107. Prior to issuance of a grading permit, final approved soils and geology reports must be submitted to the City Engineer and Public Works Director. The approved final report must encompass all subsequent reports, addendums, and revisions under a single cover. Where liquefaction hazard site conditions exist, an extra copy of the final report must be provided by the applicant to the City Engineer and Public Works Director and be sent by the applicant to the California Department of Conservation, Division of Mines and Geology in accordance with Public Resources Code Section 2697 within 30 days of report approval. 108. Prior to issuance of the grading permit, a grading remediation plan and report must be submitted for review and approval of the City Engineer and Public Works Director. The report must evaluate all major graded slopes and open space hillsides whose performance could affect planned improvements. The slope stability analysis must be performed for both static and dynamic conditions, using an appropriate pseudo -static horizontal ground acceleration coefficient for earthquakes on faults, capable of impacting the project in accordance with standard practice as outlined in DMG Special Publication No. 117, 1997. 109. Prior to issuance of the grading permit, the project geotechnical engineer shall evaluate liquefaction potential. Where liquefaction is found to be a hazard, a remediation plan with effective measures to avoid and control damage must be provided to the City Engineer and Public Works Director. During construction, measures to reduce seismic liquefaction risks shall be employed as recommended in the approved remediation plan and associated geotechnical report, such as placement of a non -liquefiable cap over the alluvium, removal of the liquefiable soils, in-situ densification, or the excavation of a shear key below the base of the liquefiable zone. Where liquefaction hazard site conditions exist, the applicant shall provide an extra copy of the final report to the City Engineer and Public Works Director and shall send a copy of the report to the California Department of Conservation, Division of Mines and Geology in accordance with Public Resources Code Section 2697 within 30 days of report approval. Resolution No. 2021-657 Page 18 110. The project must comply with all NPDES requirements and the City of Moorpark standard requirements for temporary storm water diversion structures during all construction and grading. 111. Prior to issuance of a grading permit, a qualified, currently registered Professional Civil Engineer in good standing in the State of California shall be retained to prepare Erosion and Sediment Control Plans in conformance with the currently issued Ventura County Municipal Strom Water NPDES Permit. These Plans shall address, but not be limited to, construction impacts and long- term operational effects on downstream environments and watersheds. The Plans must consider all relevant NPDES requirements and recommendations for the use of the best available technology and specific erosion control measures, including temporary measures during construction to minimize water quality effects to the maximum extent practicable. Prior to the issuance of an initial grading permit, review and approval by the Community Development Director and City Engineer and Public Works Director is required. 114. Grading plans must include, but not be limited to entry walls and project identification signs in accordance with City standards. Landscaping, appropriate to the entry, shall be provided that will not interfere with sight- distance or turning movement operations. The final design for the project entrance must be reviewed and approved by the Community Development Director and the City Engineer and Public Works Director. 115. During grading, the project geotechnical engineer shall observe and approve all keyway excavations, removal of fill and landslide materials down to stable bedrock or in-place material, and installation of all sub -drains including their connections. All fill slope construction must be observed and tested by the project geotechnical engineer, and the density test results and reports submitted to the City Engineer and Public Works Director to be kept on file. Cuts and slopes must be observed and mapped by the project geotechnical and civil engineers who will provide any required slope modification recommendations based on the actual geologic conditions encountered during grading. Written approval from the City Engineer and Public Works Director must be obtained prior to any modification. 116. Written weekly progress reports and a grading completion report must be submitted to the City Engineer and Public Works Director by the project geotechnical engineers. These reports must include the results and locations of all compaction tests, as -built plans of all landslide repairs and fill removal, including geologic mapping of the exposed geology of all excavations showing cut cross-sections and sub -drain depths and locations. The lists of excavations approved by the engineering geologist must also be submitted. Building permits will not be issued without documentation that the grading and other pertinent work has been performed in accordance with the geotechnical report criteria and applicable Grading Ordinance provisions. Resolution No. 2021-657 Page 19 117. During grading, colluvial soils and landslide deposits within developed portions of the properties must be re -graded to effectively remove the potential for seismically -induced landslides in these materials. Additional buttressing, keying and installation of debris benches must be provided in transition areas between non -graded areas and development as recommended in the final geotechnical reports by the project geotechnical engineer. 118. The recommendations for site grading contained in the final geotechnical reports must be followed during grading unless modifications are submitted for approval by the engineers -of -work and specifically approved in writing by the City Engineer and Public Works Director. 119. Temporary irrigation, hydroseeding and erosion control measures, approved by the Community Development Director, City Engineer and Public Works Director, must be implemented on all temporary grading. Temporary grading is defined to be any grading partially completed and any disturbance of existing natural conditions due to construction activity. These measures will apply to a temporary or permanent grading activity that remains or is anticipated to remain unfinished or undisturbed in its altered condition for a period of time greater than thirty (30) calendar days except that during the rainy season (October 1 to April 15), these measures will be implemented immediately. 120. The maximum gradient for any slope must not exceed a 2: 1 (horizontal: vertical) slope inclination except where special circumstances exist. In the case of special circumstances, where steeper slopes are warranted, a registered soils engineer and a licensed landscape architect will review plans and their recommendations will be subject to the review and approval of the City Engineer, Public Works Director, and the Community Development Director. 121. All graded slopes steeper than 5:1 (horizontal: vertical) must have soil amendments added, irrigation systems installed and be planted in a timely manner with groundcover, trees, and shrubs (consistent with the approved landscape and irrigation plans) to stabilize slopes and minimize erosion. Timely manner means that the slope soil amendments, irrigation systems and planting on each slope must commence immediately upon the completion of the grading of each slope, that the completion of slope grading will not be artificially delayed and that the slope soil amendments, irrigation systems and planting must be completed on a schedule commensurate with the grading. The planting will be to the satisfaction of the Community Development Director, City Engineer, and Public Works Director. 122. Grading may occur during the rainy season from October 1 to April 15, subject to timely installation of erosion control facilities when approved in writing by the City Engineer, Public Works Director, and the Community Development Director and Resolution No. 2021-657 Page 20 when erosion control measures are in place. In order to start or continue grading operations between October 1 and April 15, project -specific erosion control plans that provide detailed Best Management Practices for erosion control during the rainy season must be submitted to the City Engineer and Public Works Director no later than September 1 of each year that grading is in progress. During site preparation and construction, the contractor shall minimize disturbance of natural groundcover on the project site until such activity is required for grading and construction purposes. During the rainy season, October 1 through April 15, all graded slopes must be covered with a woven artificial covering immediately after completion of each graded slope. Grading operations must cease if the applicant fails to place effective best management measures on graded slopes immediately after construction. No slopes may be graded or otherwise created when the National Weather Service local three-day forecast for rain is twenty percent (20%), or greater, unless the applicant is prepared to cover the permanent and temporary slopes before the rain event. The artificial covering and planting will be to the satisfaction of the Community Development Director, City Engineer, and Public Works Director. 123. During clearing, grading, earth moving, excavation, soil import and/or soil export operations, the applicant shall comply with the City of Moorpark standard requirements for dust control, including, but not be limited to, minimization of ground disturbance, application of water/chemicals, temporary/permanent ground cover/seeding, street sweeping, and covering loads of dirt. All clearing, grading, earth moving, excavation, soil import and/or soil export operations must cease during periods of high winds (greater than 15 mph averaged over one hour). 124. Backfill of any pipe or conduit must be in four -inch (4") fully compacted layers unless otherwise specified, in writing, by the City Engineer and Public Works Director. 125. Soil testing for trench compaction must be performed on all trenching and must be done not less than once every two feet (2') of lift and one -hundred lineal feet (100') of trench excavated. Test locations must be noted using true elevations and street stationing with offsets from street centerlines. 126. Prior to issuance of each building permit, the project geotechnical and/or soils engineer shall submit an as -graded geotechnical report and a rough grading certification for said lot and final soils report compiling all soils reports, addendums, certifications, and testing on the project for review and approval by the City Engineer and Public Works Director. 127. Prior to issuance of the first building permit, the project's engineer shall certify that the grading and improvements have been completed, as noted on the original approved plans and any subsequent change orders. Resolution No. 2021-657 Page 21 128. When required by the Community Development Director and/or the City Engineer and/or Public Works Director, at least one (1) week prior to commencement of grading or construction, the applicant shall prepare a notice that grading or construction work will commence. This notice shall be posted at the site and mailed to all owners and occupants of property within five -hundred feet (500') of the exterior boundary of the project site, as shown on the latest equalized assessment roll. The notice must include current contact information for the applicant, including all persons with authority to indicate and implement corrective action in their area of responsibility, including the name of the contact responsible for maintaining the list. The names of individuals responsible for noise and litter control, tree protection, construction traffic and vehicles, erosion control, and the twenty-four (24) hour emergency number, must be expressly identified in the notice. The notice must be re -issued with each phase of major grading and construction activity. A copy of all notices must be concurrently transmitted to the Community Development Department. The notice record for the City must be accompanied by a list of the names and addresses of the property owners notified and a map identifying the notification area. 129. Consistent with the final geotechnical reports, at a minimum, the following measures must be implemented during design and construction where appropriate to minimize expansive soil effects on structures: potential foundation systems to include pier and grade beam; use of structural concrete mats and post - tensioned slabs; pad overcutting to provide uniform swell potential; and soil subgrade moisture treatment. 130. Prior to issuance of building permits, chemical testing of representative building pad soils is required to determine the level of corrosion protection required for steel and concrete materials used for construction. The following measures must be implemented where appropriate to protect against corrosion: • use of sulfate -resistant concrete; and • use of protective linings to encase metallic piping buried in soils warranting such measures. 131. Engineered fills must be constructed in compliance with the standards and criteria presented in the approved geotechnical report. The differential thickness of the fill under individual buildings may not be greater than ten (10) feet. These measures must be verified by construction observation and testing by the project geotechnical engineer as outlined in the final geotechnical reports and approved by the City Engineer and Public Works Director. 132. Additional analysis of the predicted total and differential settlements of the major fills at each site must be performed by the project geotechnical engineer during Resolution No. 2021-657 Page 22 the final design stage. Possible measures that may be required based on the settlement data include surcharging, delaying construction for a period of time before constructing on deep fills, or allowing for the predicted settlement in the design of the project components. 133. Transfer of responsibility of California Registered Civil Engineer in charge for the project must be in accordance with rules and guidelines set forth pursuant to Rules of the Board for Professional Engineers and Land Surveyors, California Code of Regulations, Title 16, Division 5, Board Rule 404.1, Subsections (c) and (d), that speak to Successor Licensee and Portions of Projects. Applicant has full right to exercise the service of a new engineer in charge at any time during a project. When there is a change in engineer, the applicant/owner shall notify the City Engineer and Public Works Director in writing within 48 hours of such change. Said letter shall specify successor California Registered Civil Engineer and shall be stamped and signed and dated by said engineer in responsible charge and shall accept responsibility of project. The letter will be kept on file at the City. PUBLIC AND PRIVATE STREETS AND RELATED IMPROVEMENTS 144. Prior to construction of any public improvement, the applicant shall submit to the City Engineer and Public Works Director, for review and approval, street improvement plans prepared by a California Registered Civil Engineer, and enter into an agreement with the City of Moorpark to complete public improvements, with sufficient surety posted to guarantee the complete construction of all improvements, except as specifically noted in these Standard Conditions or Special Conditions of Approval. 145. Prior to issuance of the first building permit, all existing and proposed utilities, including electrical transmission lines less than 67Kv, must be under -grounded consistent with plans approved by the City Engineer, Public Works Director and Community Development Director. Any exceptions must be approved by the City Council. 146. Above -ground obstructions in the right-of-way (utility cabinets, mailboxes, etc.) must be placed within landscaped areas when landscaped areas are part of the right-of-way improvements. When above ground obstructions are placed within the sidewalk, a minimum of five feet (5') clear sidewalk width must be provided around the obstruction. Above -ground obstructions may not be located within or on multi-purpose trails. 147. Prior to final inspection of improvements, the project Registered Civil Engineer shall submit certified original "record drawing" plans with three (3) sets of paper prints and the appropriate plan revision review fees to the City Engineer and Resolution No. 2021-657 Page 23 Public Works Director along with electronic files in a format satisfactory to the City Engineer and Public Works Director. These "record drawing" plans must incorporate all plan revisions and all construction deviations from the approved plans and revisions thereto. The plans must be "record drawings" on 24" X 36" Mylar® sheets (made with proper overlaps) with a City title block on each sheet. In addition, the applicant shall provide an electronic file update of the City's Master Base Map electronic file, incorporating all streets, sidewalks, street lights, traffic control facilities, street striping, signage and delineation, storm drainage facilities, water and sewer mains, lines and appurtenances and any other utility facility installed for this project. 148. The street improvement plans must contain a surveyor's statement on the plans, certifying that, in accordance with Business and Professions Code 8771, all recorded monuments in the construction area will be protected in place during construction, or have been located and tied with no fewer than four (4) durable reference monuments, which will be protected in place during construction. Copies of all monument tie sheets must be submitted to the City on reproducible 3 -mil polyester film. 149. Prior to reduction of improvement bonds, the applicant must submit reproducible centerline tie sheets on 3 -mil polyester film to the City Engineer and Public Works Director. 150. All streets must conform to the latest City of Moorpark Engineering Policies and Standards using Equivalent Single Axle Loads (ESAL) for a minimum thirty (30) year term for public streets and ESAL for a twenty (20) year term on private streets. All streets must be designed and constructed to the required structural section in conformance with the latest City of Moorpark Engineering Policies and Standards. The geotechnical or soil reports must address the need for possible sub -drainage systems to prevent saturation of the pavement structural section or underlying foundation. An additional one and one-half inch (1-1/2") thick rubberized asphalt pavement must be added to the structural section for public streets. This additional pavement may not be used in determining the required structural section. DRAINAGE AND H DROLOG 152. Prior to approval of a grading plan, the applicant shall submit to the City of Moorpark for review and approval by the City Engineer and Public Works Director, drainage plans with the depiction and examination of all on-site and off-site drainage structures and hydrologic and hydraulic calculations in a bound and indexed report prepared by a California Registered Civil Engineer. 153. Drainage improvements must be designed so that after -development, drainage to adjacent parcels would not be increased above pre -development drainage Resolution No. 2021-657 Page 24 quantities for any stormwater model between and including the 10 year and 100 year storms, nor will surface runoff be concentrated by this project. Acceptance of storm drain waters by the project and discharge of storm drain waters from the project must be in type, kind and nature of predevelopment flows unless the affected upstream and/or downstream owners provide permanent easement to accept such changed storm drainage water flow. All drainage measures necessary to mitigate stormwater flows must be provided to the satisfaction of the City Engineer and Public Works Director. The applicant shall make any on- site and downstream improvements, required by the City, to support the proposed development. 154. The drainage plans and calculations must analyze conditions before and after development, as well as, potential development proposed, approved, or shown in the General Plan. Quantities of water, water flow rates, major watercourses, drainage areas and patterns, diversions, collection systems, flood hazard areas, sumps, sump locations, detention and NPDES facilities and drainage courses must be addressed. 156. All stormwater surface runoff for the development must have water quality treatment to meet the design standards for structural or treatment control BMPs per the latest issued Ventura County Municipal Storm Water NPDES Permit. 157. The hydraulic grade line within any catch basin may not extend higher than nine inches (9") below the flow line grade elevation at the inlet. 161. The maximum velocity in any storm drain system may not exceed twenty feet (20') per second. 162. All detention and debris structures that fall under the definition of being a dam must have an open air spillway structure that directs overflows to an acceptable location to the satisfaction of the City Engineer and Public Works Director. 163. Only drainage grates of a type approved by the City Engineer and Public Works Director may be used at locations accessible by pedestrian, bicycle, or equestrian traffic. Drainage grates shall not be allowed in sidewalks or trails. 164. To verify that the Reinforced Concrete Pipe (RCP) specified on the improvement plan is correct, the RCP delivered to project site must have the D- LOAD specified on the RCP. 165. The grading plan must show distinctive lines of inundation delineating the 100 - year flood level. 166. All flows that have gone through flow attenuation and clarification by use of acceptable Best Management Practice Systems and are flowing within brow Resolution No. 2021-657 Page 25 ditches, ribbon gutters, storm drain channels, area drains and similar devices are to be deposited directly into the storm drain system unless an alternative has been approved by the City Engineer and Public Works Director. Storm drain and related easements outside the public right-of-way are to be privately . maintained unless otherwise approved by the City Council. 167. Concrete surface drainage structures exposed to the public view must be tan colored concrete, as approved by the Community Development Director, and to the extent possible must incorporate natural structure and landscape to blend in with the surrounding material. 168. Prior written approval by the City Engineer and Public Works Director is required for curb outlets that provide for pad or lot drainage onto the street. 169. Drainage devices for the development must include all necessary appurtenances to safely contain and convey storm flows to their final point of discharge to the satisfaction of the City Engineer and Public Works Director. 170. The applicant shall demonstrate, for each building pad within the development area, that the following restrictions and protections can be put in place to the satisfaction of the City Engineer and Public Works Director: a. Adequate protection from a one -hundred (100) year frequency storm; b. Feasible access during a fifty (50) year frequency storm. C. Elevation of all proposed structures within the one -hundred (100) year flood zone at least one (1') foot above the one -hundred (100) year flood level. Hydrology calculations must be per current Ventura County Watershed Protection Agency Standards and to the satisfaction of the City Engineer and Public Works Director. Development projects within a 100 -year flood zone may require a Conditional Letter of Map Revisions (CLOMR) and Letter of Map Revision (LOMR) as determined by the City Engineer and Public Works Director. 171. The storm drain system must be designed with easements of adequate width for future maintenance and reconstruction of facilities, particularly facilities deeper than eight feet (8'). In addition, all facilities must have all-weather vehicular access. 172. All existing public storm drain systems within the development require pre - construction and post -construction Closed Caption Television Videoing (CCTV) including identification by existing plan and station. Resolution No. 2021-657 Page 26 173. Storm drain systems must be constructed per the most current Ventura County Watershed Protection District Standard Design Manual, City of Moorpark Standards and to the satisfaction of the City Engineer and Public Works Director. 174. All storm drain easement widths and alignments must conform to the City of Moorpark requirements and be to the satisfaction of the City Engineer and Public Works Director. Easements must provide sufficient room for reconstruction of the storm drain systems and provide all weather access within the easement, to all manholes, inlets, outlets and any other structure that requires maintenance. NATIONAL POLLUTANT DISCHARGE ELIMINATION S STEM NPDES 175. Prior to the start of grading or any ground disturbance, the applicant shall identify a responsible person experienced in NPDES compliance who is acceptable to the City Engineer and Public Works Director. The designated NPDES person (superintendent) shall be present, on the project site Monday through Friday and on all other days when the probability of rain is forty percent (40%) or greater and prior to the start of and during all grading or clearing operations until the release of grading bonds. The superintendent shall have full authority to rent equipment and purchase materials to the extent needed to effectuate Best Management Practices. The superintendent shall be required to assume NPDES compliance during the construction of streets, storm drainage systems, all utilities, buildings, and final landscaping of the site. 176. Prior to the issuance of any construction/grading permit and/or the commencement of any qualifying grading or excavation, the applicant shall prepare and submit a Stormwater Pollution Control Plan (SWPCP), on the form established in the Ventura Countywide Stormwater Quality Management Program. The SWPCP must address the construction phase compliance to stormwater quality management regulations for the project. The SWPCP, improvement plans and grading plans must note that the contractor shall comply with the California Best Management Practices Construction Handbook, published by the California Stormwater Quality Association. The SWPCP must be submitted, with appropriate review deposits, for the review and approval of the City Engineer and Public Works Director. The SWPCP must identify potential pollutant sources that may affect the quality of discharges and design the use and placement of Best Management Practices (BMPs) to effectively prohibit the entry of pollutants from the construction site into the storm drain system during construction. Erosion control BMPs, which include wind erosion, dust control, and sediment source control BMPs for both active and inactive (previously disturbed) construction areas are required. 177. The SWPCP must include provisions for modification of BMPs as the project progresses and as conditions warrant. The City Engineer and Public Works Director may require the first version and each subsequent revision of the SWPCP Resolution No. 2021-657 Page 27 to be accompanied by a detailed project schedule that specifically identifies the type and location of construction operations for the project. The SWPCP must be developed and implemented in accordance with the latest issued Ventura Countywide Stormwater Quality Management Program, NPDES Permit, Chapter 8.52 of the Moorpark Municipal Code and any other requirements established by the City. The applicant is responsible for ensuring that all project contractors, subcontractors, materials suppliers, tenants, and tenants' contractors comply with all BMPs in the SWPCP, until such time as a notice of termination has been approved by the City Engineer and Public Works Director and accepted by the Los Angeles Regional Water Quality Control Board. The SWPCP must include schedules and procedures for onsite maintenance of earthmoving and other heavy equipment and documentation of proper disposal of used oil and other lubricants. Onsite maintenance of all equipment that can be performed offsite will not be allowed. 178. Prior to the issuance of any construction/grading permit and/or the commencement of any qualifying, grading or excavation, the applicant for projects with facilities identified as subject to the State Board General Industrial and Commercial permits shall prepare and submit a Stormwater Pollution Prevention Plan (SWPPP). The SWPPP must address post -construction compliance with stormwater quality management regulations for the project. The SWPPP, improvement plans, and grading plans must note that the contractor shall comply with the latest edition of the California Best Management Practices New Development and Redevelopment Handbook, published by the California Stormwater Quality Association. The SWPPP must comply with the Ventura Countywide Stormwater Quality Management Program Land Development Guidelines, Technical Guidance Manual for Stormwater Quality Control Measures, and the Stormwater Management Program (SMP) to develop, achieve, and implement a timely, comprehensive, cost effective stormwater pollution control program to reduce pollutants to the maximum extent practicable. The SWPPP must be prepared in compliance with the form and format established in the Ventura Countywide Stormwater Quality Management Program, and submitted, with appropriate review deposits, for the review and approval of the City Engineer/Public Works Director. The proposed plan must also address all relevant NPDES requirements, maintenance measures, estimated life spans of Best Management Practices facilities, operational recommendations, and recommendations for specific Best Management Practices technology, including all related costs. The use of permanent dense ground cover planting approved by the City Engineer/Public Works Director and Community Development Director is required for all graded slopes. Methods of protecting the planted slopes from damage must be identified. Proposed management efforts during the lifetime of the project must include best available technology. "Passive" and "natural" BMP drainage facilities are to be provided such that surface flows are intercepted and treated on the surface over biofilters (grassy swales), infiltration areas and other similar solutions. The use of filters, separators, clarifiers, absorbents, adsorbents, Resolution No. 2021-657 Page 28 or similar "active" devices is not acceptable and may not be used without specific prior approval of the City Council. The use of biological filtering, bio- remediation, infiltration of pre -filtered stormwater and similar measures that operate without annual maintenance intervention, that are failsafe, that, when maintenance is needed, will present the need for maintenance in an obvious fashion and which will be maintainable in a cost effective and non -disruptive fashion is required. As deemed appropriate for each project, the SWPPP must establish a continuing program of monitoring, operating and maintenance to: a. Provide discharge quality monitoring. b. Assess impacts to receiving water quality resulting from discharged waters. c. Identify site pollutant sources. d. Educate management, maintenance personnel and users, to obtain user awareness and compliance with NPDES goals. e. Measure management program effectiveness. Investigate and implement improved BMP strategies. g. Maintain, replace, and upgrade BMP facilities (establish BMP facility inspection standards and clear guidelines for maintenance and replacement). Secure the funding, in perpetuity, to achieve items "a" through "g" above. 179. Prior to the issuance of any construction/grading permit and/or the commencement of any clearing, grading or excavation, the applicant shall submit a Notice of Intent (NOi) to the California State Water Resources Control Board, Stormwater Permit Unit in accordance with the latest issued NPDES Construction General Permit: Waste Discharge Requirements for Discharges of Stormwater Runoff Associated with Construction Activities). The applicant shall also provide a copy of the Notice of Intent (NOi) to the City Engineer and Public Works Director as proof of permit application. The improvement plans and grading plans shall contain the Waste Discharge Identification number for the project. 180. Engineering and geotechnical or soils reports must be provided to prove, to the satisfaction of the City Engineer and Public Works Director, that all "passive" NPDES facilities meet their intended use and design. These facilities shall meet the minimum requirements relating to water detention and clarification. 181. The applicant shall comply with Chapter 8.52 of the Moorpark Municipal Code and any provision amendatory and supplementary thereto. Resolution No. 2021-657 Page 29 VENTURA COUNT AIR POLLUTION CONTROL DISTRICT STANDARD CONDITIONS 183. Prior to issuance of a Zoning Clearance for building permit, a Ventura County Air Pollution Control District (APCD) "Authority to Construct" shall be obtained for all equipment subject to APCD Permit (see APCD Questionnaire, A133205). Final Certificate of Occupancy shall not be granted until compliance with all applicable APCD Rules & Regulations has been satisfactorily demonstrated. 184. Facilities shall be operated in accordance with the Rules and Regulations of the Ventura County Air Pollution Control District, with emphasis on Rule 51, Nuisance. Rule 51 states: "A person shall not discharge from any source whatsoever such quantities of air contaminants or other material which cause injury, detriment, nuisance or annoyance to any considerable number of persons or to the public or which endangers the comfort, repose, health or safety of any such persons or the public or which cause or have a natural tendency to cause injury or damage to business or property." VENTURA COUNT FIRE PROTECTION DISTRICT STANDARD CONDITIONS 185. Prior to combustible construction, an all-weather access road/driveway and the first lift of the access road pavement must be installed. Once combustible construction starts a minimum twenty -foot (20') clear width access road/driveway must remain free of obstruction during any construction activities within the development. All access roads/driveways must have a minimum vertical clearance of thirteen feet -six inches (13'-6") and a minimum outside turning radius of forty feet (40'). 186. Approved turnaround areas for fire apparatus must be provided when dead-end Fire District access roads/driveways exceed 150 -feet. Turnaround areas may not exceed a five percent cross slope in any direction and must be located within one - hundred -fifty feet (150') of the end of the access road/driveway. 187. The access road/driveway must be extended to within one -hundred -fifty feet (150') of all portions of the exterior wall of the first story of any building and must be in accordance with Fire District access standards. Where the access roadway cannot be provided, approved fire protection system or systems must be installed as required and acceptable to the Fire District. 190. Approved walkways must be provided from all building openings to the public way or Fire District access road/driveway. 192. All new structures must be provided with an automatic fire sprinkler system in accordance with current Ventura County Fire Protection District Ordinance. Resolution No. 2021-657 Page 30 193. Commercial trash dumpsters and containers with an individual capacity of 1.5 cubic yards or greater may not be stored or placed within five feet of openings, combustible walls, or combustible roof eave lines unless protected by approved automatic sprinklers. 194. Gating of private streets or parking areas must meet the requirements of Chapter 17.32 of the Moorpark Municipal Code and any provision amendatory and supplementary thereto and of the Ventura County Fire Protection District. DEVELOPMENT REQUIREMENTS 199. Prior to the issuance of a certificate of occupancy by the Building Division, the applicant shall submit a plan to the Fire District for review and approval indicating the method by which this project will be addressed. 200. Minimum six-inch (6") high address numbers must be installed prior to occupancy, must be contrasting color to the background, and must be readily visible at night Brass or gold plated number may not be used. Where structures are set back more that one -hundred -fifty feet (150') from the street, larger numbers are required so that they are distinguishable from the street. In the event a structure(s) is (are) not visible from the street, the address numbers(s) must be posted adjacent to the driveway entrance on an elevated post. 201. Prior to combustible construction, fire hydrants must be installed to the minimum standards of the City of Moorpark and the Fire District, and must be in service. 202. Prior to occupancy of any structure, blue reflective hydrant location markers must be placed on the access roads in accordance with Fire District standards. If the final asphalt cap is not in place at time of occupancy, hydrant location markers must still be installed and replaced when the final asphalt cap is completed. 203. Prior to the issuance of a building permit, building plans for all A, E, H, I, R-1, and R-2 Occupancies must be submitted, with payment for plan check, to the Fire District for review and approval. 204. Prior to issuance of a building permit the applicant must submit a phasing plan and two (2) site plans (for the review and approval of the location of fire lanes) to the Fire District. 205. Prior to occupancy, the fire lanes must be posted "NO PARKING FIRE LANE TOW -AWAY" in accordance with California Vehicle Code and the Fire District. 206. Prior to or concurrently with the issuance of a building permit, the applicant shall submit plans to the Fire District showing the location of the existing hydrants within Resolution No. 2021-657 Page 31 three -hundred feet (300') of the proposed project and showing the location, type and number of proposed hydrants, and the size of the outlets. Fire hydrant(s) shall be provided in accordance with current adopted edition of the Uniform Fire Code, Appendix 111-B and adopted amendments. On-site fire hydrants may be required as determined by the Fire District. Fire hydrants, if required, must be installed and in service prior to combustible construction and must conform to the minimum standard of the Ventura County Waterworks Manual and the Fire District. 207. Prior to installation of any fire protection system; including, but not limited to sprinklers, dry chemical, hood systems, the applicant shall submit plans, along with the required fee for plan check, to the Fire District for review and approval. Fire sprinkler systems with one -hundred or more heads must be supervised by a fire alarm system in accordance with Fire District requirements. 208. Prior to installation of the fire alarm system (if required), the applicant shall submit plans, along with the required fee for plan check, to the Fire District for review and approval. The fire alarm system must be installed in all buildings in accordance with California Building and Fire Code. 209. Prior to the issuance of a certificate of occupancy by the Building Division, the applicant shall obtain all applicable Uniform Fire Code (UFC) permits. 210. Prior to the issuance of a building permit, the applicant shall obtain a copy of Ventura County Fire District Form No. 126 "Requirements for Construction." 211. Prior to the issuance of a certificate of occupancy by the Building Division, the applicant shall install fire extinguishers in accordance with the Uniform Fire Code. The placement of extinguishers is subject to review and approval by the Fire District. 212. Prior to framing, the applicant shall clear for a distance of one hundred feet all grass or brush exposing any structure(s) to fire hazards. VENTURA COUNT WATERWORKS DISTRICT NO. 1 STANDARD CONDITIONS 213. The applicant shall comply with the applicable provisions of Ventura County Waterworks District No. 1 standard procedures for obtaining domestic water and sewer services for applicant's projects within the District. 214. Prior to the issuance of a building permit, the applicant shall provide Ventura County Waterworks District with: a. Water and sewer improvement plans in the format required. b. Hydraulic analysis by a registered Civil Engineer to determine the adequacy of the proposed and existing water and sewer lines. Resolution No. 2021-657 Page 32 C. Copy of fire hydrant location approvals by Ventura County Fire Protection District. d. Copy of District Release and Receipt from Calleguas Municipal Water District. e. Cost estimates for water and sewer improvements. f. Plan check, construction inspection, capital improvement charge, sewer connection fee and water meter charge. g. Signed Contract to install all improvements and a Surety Bond. 215. At the time water service connection is made, cross connection control devices must be installed on the water system in a manner approved by the Ventura County Waterworks District No. 1. VENTURA COUNT WATERSHED PROTECTION DISTRICT STANDARD CONDITIONS 216. Direct storm drain connections to Ventura County Flood Control District facilities are subject to Ventura County Watershed Protection District permit requirements. VENTURA COUNT POLICE DEPARTMENT STANDARD CONDITIONS 217. Prior to initiation of the building plan check process for the project, the applicant shall submit plans in sufficient detail to the Police Department for review and approval of defensible space concepts to reduce demands on police services. To the degree feasible and to the satisfaction of the Community Development Director and the Police Chief, public safety planning recommendations must be incorporated into the project plans. The applicant shall prepare a list of project features and design components that demonstrate responsiveness to defensible space design concepts. STANDARD CONDITIONS OF APPROVAL FOR CONDITIONAL USE PERMITS 218. Within thirty (30) calendar days of approval of this entitlement, the applicant shall sign and return to the Planning Division an Affidavit of Agreement and Notice of Entitlement Permit Conditions of Approval, indicating that the applicant has read and agrees to meet all Conditions of Approval of this entitlement. The Affidavit of Agreement/Notice shall include a legal description of the subject property and have the appropriate notary acknowledgement suitable for recordation. 219. This Conditional Use Permit expires one (1) year from the date of its approval unless the use has been inaugurated by issuance of a building permit for construction. The Community Development Director may, at his/her discretion, grant up to two (2) additional one-year extensions for use inauguration of the permit if there have been no changes in the adjacent areas and if the applicant Resolution No. 2021-657 Page 33 can document that he/she has diligently worked towards use inauguration during the initial period of time. The request for extension of this permit shall be made in writing, at least thirty (30) days prior to the expiration date of the permit and shall be accompanied by applicable entitlement processing deposits. 220. The Conditions of Approval of this entitlement and all provisions of the City of Moorpark Municipal Code and adopted City policies at the time of the entitlement approval, supersede all conflicting notations, specifications, dimensions, typical sections and the like which may be shown on said plans or application. 221. Conditions of this entitlement may not be interpreted as permitting or requiring any violation of law or any unlawful rules or regulations or orders of an authorized governmental agency. 224. If any of the conditions or limitations of this approval are held to be invalid, that holding does not invalidate any of the remaining conditions or limitations set forth. SPECIAL CONDITIONS OF APPROVAL Prior to issuance of a Zoning Clearance for the issuance of the building permit, additional architectural elements, which may include columns, brick veneer or other architectural details, shall be added to the east and south building elevations to match the north and west building finishes, colors, materials, and detailing, to the satisfaction of the Community Development Director. The intent of the additional architectural details is to create a cohesive design on all faces of the structure, to break up large expanses of featureless walls on these elevations, and to deter graffiti on the east and south elevations of the building. 2. Prior to issuance of Zoning Clearance for occupancy, both driveways must be removed and reconstructed to the satisfaction of the City Engineer/Public Works Director. 3. Prior to issuance of Zoning Clearance for occupancy, broken curbs and gutters must be removed and replaced to the satisfaction of the City Engineer/Public Works Director. 4. A separate sign permit application must be submitted for all proposed signs, for the review and approval of the Community Development Director prior to issuance of a building permit for a sign. Flags, banners, balloons, pennants, and handheld signs not otherwise permitted by code are expressly prohibited. 5. Outside speakers and amplified sound are prohibited at all times. 6. All outdoor lighting must comply with Chapter 17.30 of the Moorpark Municipal Code (Lighting Regulations). Resolution No. 2021-657 Page 34 7. A parking, landscaping, and irrigation plan subject to review and approval of the Community Development Director and Parks, Recreation, and Community Services Director must be submitted. Landscaping must include removal of concrete from parkway and replacement with acceptable landscaping, including replacement of deteriorated meter box. All site improvements must be completed prior to final occupancy. 8. Approval of a Zoning Clearance is required prior to the issuance of plan check, building and occupancy permits. All other permit and fee requirements shall be met and property maintenance violations at the site shall be abated prior to occupancy to the satisfaction of the Community Development Director. 9. No outdoor storage is allowed under this approval. Any request for outdoor storage is subject to the application requirements in place at the time of such request. 10. No outdoor repair or maintenance, including major washing, cleaning, or detailing of vehicles is allowed under this permit. All mechanical equipment (e.g., air compressors) must also be kept inside the building. 11. No heavy service or repair such as auto body shop, painting, engine rebuilding, transmission repair, steam cleaning and other heavy services are allowed. 12. Vehicles brought in for service may only be parked within the parking spaces designated for this building during open hours of operation and may not be parked in driveway, street, or in the alley. All vehicles left for service overnight and on weekends (outside business hours), both operative and inoperative, must be parked inside the service bays. 13. The applicant shall comply with Chapter 8.32 PROHIBITING SMOKING IN PUBLIC PLACES at all times and shall provide signs consistent with Section 8.32.040 of the Moorpark Municipal Code to the satisfaction of the Community Development Director, prior to initiation of the uses allowed by this permit. Any smoking area, if desired, shall comply with Section 8.32.030 of the Moorpark Municipal Code. 14. Trash, recycling and potential food waste services must be provided by the City's franchised waste hauler, Waste Management. Services may be set up by calling (805) 522-9400. Use of any other third -party waste hauler is prohibited. 15. The proprietor shall reimburse the City of Moorpark for any additional police or other costs incurred by the City as a result of operations of the facility, including 15% overhead on any such services. Resolution No. 2021-657 Page 35 16. All necessary permits must be obtained from the Building and Safety Division and all construction shall be in compliance with the Moorpark Building Code and all other applicable regulations. PARKS, RECREATION AND COMMUNIT SERVICES DEPARTMENT SPECIAL CONDITIONS 17. The final landscape plans shall be prepared by a California Licensed Landscape Architect. The plans shall include at a minimum a demolition plan, planting plan and irrigation plan, including all relevant details and specifications. The plans shall also conform to the State's Model Water Efficient Landscape Ordinance and shall include all relevant water use calculations. The final landscape plans shall be designed to achieve the standards outlined in the City of Moorpark Landscape Standards and Guidelines and landscape standards in the Downtown Specific Plan. 18. The applicant is required to obtain an arborist report for any trees on the property that are proposed for removal. The arborist report should provide a tree valuation and the landscape plans should include 'enhanced landscaping' equal to the value of the trees removed. This can typically be accomplished by upsizing the tree sizes. For instance, 24" box trees are required in parking lots. The applicant could install 48" box trees in lieu of 24" box trees, and the difference in the cost of the trees would go towards the value of the trees removed. 19. Enhanced landscape is required at all project entries. A large `feature' tree shall be installed behind the new monument sign to meet this requirement. 20. Vines on a metal trellis(es) shall be installed on the south side of the building to the satisfaction of the Community Development Director. 21. The City's Landscape Design Criteria require (1) tree for every (4) parking stalls. One additional tree needs to be included. Either a new planting island will need to be included, or the curb will need to be modified in order to accommodate the tree. The curb was modified to accommodate a shade tree, however a tree is not proposed for the planter that was provided. Citrus trees are not appropriate shade trees for parking areas. Trees shall be installed at the ends of the parking areas in the planter areas. 22. Street trees shall be installed no less than 30' o.c. It is difficult to determine if the appropriate spacing has been accommodated, but three (3) street trees are required in the parkway. Use of California native trees and shrubs is highly encouraged. Western Redbud may be an appropriate tree in the parkway and would avoid powerlines. VENTURA COUNT POLICE DEPARTMENT SPECIAL CONDITIONS Resolution No. 2021-657 Page 36 23. Trash enclosures shall be secured to prevent unpermitted access or use. 24. An exterior lighting coverage plan shall be prepared to show adequate lighting of exterior areas to deter after hours loitering, graffiti or other unpermitted activities on adjacent to the project site. Lighting shall be provided on all faces of the building and include motion sensors for after business hours. Lighting coverage shall be approved by the Community Development Department prior to issuance of Zoning Clearance for the construction of the building. 25. Applicant shall submit a security plan to the Police Department prior to occupancy. Security plan shall include type and location of cameras. Applicant should consider registering cameras with the Ventura County Sheriff's Office Video Surveillance Camera Registration program. 26. Graffiti resistant paint or coatings shall be installed on all low building faces. 27. All lighting to conform to Illuminating Engineering Society (IES) standards. 28. Applicant shall ensure all exterior access doors are equipped with a window, viewport, or similar device to assist with employee safety. 29. The facility must correct any safety or security problem within three (3) days upon written notice of such a problem from the Moorpark Police Department. VENTURA COUNT FIRE PROTECTION DISTRICT VCFPD SPECIAL CONDITIONS 30. The property owner(s) are hereby advised that parking on access roads / driveways and fire department turnarounds is prohibited. 31. Any gates to control vehicle access are to be located to allow a vehicle waiting for entrance to be completely off the intersecting roadway. A minimum clear open width of 15 feet in each direction shall be provided for separate entry / exit gates and a minimum 20 for combined entry / exit gates. If gates are to be locked, a Knox system shall be installed. The method of gate control, including operation during power failure (battery back-up), shall be subject to review by the Fire Prevention Division. Gate plan details shall be submitted to the Fire District for approval prior to installation. A final acceptance inspection by the Fire District is required prior to placing any gate into service. 32. All exit doors shall swing in the direction of travel (outwards) when leaving the building. 33. All required egress aisles shall be maintained clear of obstructions at anytime. Resolution No. 2021-657 Page 37 34. All emergency lights and exit signs shall be maintained in an operable condition at all times. 35. The minimum fire flow required shall be determined as specified by the current adopted edition of the International Fire Code Appendix B with adopted Amendments and the applicable Water Manual for the jurisdiction (with ever is more restrictive). The applicant shall verify that the water purveyor can provide the required volume and duration at the project prior to obtaining a building permit. 36. Plans for water systems supplying fire hydrants and / or fire sprinkler systems and not located within a water purveyor's easement, shall be submitted to the Fire District for review and approval prior to issuance of grading and/or building permits or signing of Mylar plans, whichever is first. Plans shall reflect only dedicated private fire service lines and associated appurtenances. Plan shall be design and submitted with the appropriate fees in accordance with VCFPD Standard 14.7.2. 37. All structures shall be provided with an automatic fire sprinkler system in accordance with current VCFPD Ordinance at time of building permit application. 38. Plans for all fire protection systems (sprinklers, dry chemical, hood systems, etc.) shall be submitted, with payment for plan check, to the Fire District for review and approval prior to installation. Note: Fire sprinkler systems with 6 or more heads shall be supervised by a fire alarm system in accordance with Fire District requirements. 39. Plans for any fire alarm system or sprinkler monitoring system shall be submitted, with payment for plan check, to the Fire District for review and approval prior to installation. 40. The building fire sprinkler system shall be serviced and maintained in a proper working order at all times. Required maintenance inspections and service personnel shall be in accordance with CCR Title 19, and VCFPD Ordinance. Service and maintenance records shall be maintained on-site and available for review by the Fire Department upon request. 41. A current Five -Year Fire Sprinkler System certification shall be maintained at all times in accordance with CCR Title 19 and VCFPD requirements. The required Five -Year Report shall be submitted to the Fire Department prior to expiration of the previous Five -Year certification. 42. The building fire alarm system shall be serviced and maintained in a proper working order at all times. Required maintenance inspections and service personnel shall be in accordance with NFPA 72. Service records shall be maintained on-site and available for review by the Fire Department upon request. Resolution No. 2021-657 Page 38 43. Fire Department Clearance (Submit prior to Building & Safety approval) - Applicant shall obtain VCFD Form #126 "Requirements for Construction" prior to obtaining a building permit for any new structures or additions to existing structures. 44. Applicant and / or tenant shall obtain all applicable International Fire Code (IFC) permits prior to occupancy or use of any system or item requiring an IFC permit. -END-