HomeMy WebLinkAboutRES CC 2025 4368 2025 1203 RESOLUTION NO. 2025-4368
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF
MOORPARK, CALIFORNIA, RATIFYING VENTURA
COUNTY FIRE PROTECTION DISTRICT (VCFPD)
ORDINANCE NO. 34, ARTICLE 3 SECTION 903, ARTICLE 3
APPENDIX B AND ARTICLE 4 SECTION 604.11
PERTAINING TO BUILDING STANDARDS FOR
APPLICATION WITHIN THE CITY, RESCINDING
RESOLUTION NO. 2022-4145, AND MAKING A
DETERMINATION OF EXEMPTION UNDER CALIFORNIA
ENVIRONMENTAL QUALITY ACT (CEQA) IN
CONNECTION THEREWITH
WHEREAS, the City of Moorpark lies within the jurisdictional boundaries of the
Ventura County Fire Protection District (VCFPD) and the VCFPD has responsibility for
fire protection within said jurisdictional boundaries; and
WHEREAS, the Ventura County Fire Protection District did on October 14, 2025,
adopt Fire Protection District Ordinance No. 34, repealing Ordinances No. 29 and 32, and
adopting by reference the 2025 California Fire Code (CFC) together with Appendix
Chapters D and P, portions of the 2024 edition of the International Fire Code (IFC),
portions of the 2025 California Wildland-Urban Interface Code, portions of the 2024
International Wildland-Urban Interface Code, and portions of Title 19 of the California
Code of Regulations, with additions, deletions and amendments thereto; and
WHEREAS, Article 3 Section 903, Article 3 Appendix B and Article 4 Section
604.11 of said amendments constitute amendments containing such building standards
relating to fire and life safety and fire flow adopted by the State Fire Marshal and contained
in the California Building Standards Code; and
WHEREAS, pursuant to Section 13869.7(c) of the California Health and Safety
Code, amendments containing such building standards are not effective within the
jurisdictional boundaries of the City until ratified by the City Council; and
WHEREAS, Article 3 Section 903 contains similar building standards to those that
have been in effect and enforced within the County since June 3, 1982; and
WHEREAS, the Building standards contained within said Article 3 Section 903
are an integral part of the VCFPD fire protection response plan; and
WHEREAS, City Council Resolution No. 2022-4145 previously ratified Chapter 9
of Fire Protection District Ordinance No. 32, which was superseded by Fire Protection
District Ordinance No. 34, and as such will no longer be valid and should be rescinded
upon the effective date of Fire Protection District Ordinance No. 34.
Resolution No. 2025-4368
Page 2
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF MOORPARK
DOES HEREBY RESOLVE AS FOLLOWS:
SECTION 1. ENVIRONMENTAL DETERMINATION: The City Council has
determined that this Resolution is exempt from the provisions of the California
Environmental Quality Act(CEQA) pursuant to Section 15061(b)(3) of the California Code
of Regulations (CEQA Guidelines) based on the general rule that CEQA only applies to
"projects" that may have a significant effect on the environment. This Resolution would
amend the Municipal Code related to building standards necessary to protect health and
safety. In this case, it can be seen with certainty that there is no possibility that this
Resolution may have a significant impact on the environment. Based on the foregoing,
the City Council, based on its own independent judgment, finds that the adoption of this
Resolution is exempt from CEQA.
SECTION 2. CITY COUNCIL RATIFICATION: The City of Moorpark ratifies
without modification, Article 3 Section 903, Article 3 Appendix B and Article 4 Section
604.11 of Ventura County Fire Protection District Ordinance No. 34 as these sections
appear in Exhibit A, to be effective within the jurisdictional boundaries of the City on and
after January 1, 2026.
SECTION 3. The City Clerk shall certify to the adoption of this resolution and
shall cause a certified resolution to be filed in the book of original resolutions.
PASSED AND ADOPTED this 3rd day of December, 2025.
Chris R. Enegren, Mayor
pK
ATTEST: Szkc
o ►
40100m.,
iva
Ky Span er, ity rk ` 4iimitypi1V
ai
Exhibit A: Ventura County Fire Protection District Ordinance No. 34 091
r00
,`'`4
Resolution No. 2025-4368 EXHIBIT A
Page 3
ARTICLE 3, SECTION 903
CHAPTER 9
FIRE PROTECTION SYSTEMS
Section 903.1.2 is added to read as follows:
903.1.2 Concurrent permits. Additions or modifications where the application for a
building permit is submitted prior to the final inspection of any previously issued building
permit(s) shall require the installation of an automatic fire sprinkler system throughout
the entire Structure when the area of the addition or modification of all open permits
combined with the new application exceed the exceptions listed under Article 3, Section
903.2.
Section 903.1.3 is added to read as follows:
903.1.3 Maintenance of area separation walls. Area separation walls used to create
fire areas less than 5,000 square feet of floor area (5,000 Gross Square Feet for Group
R-3 Occupancies) in Buildings constructed under the original accepted building permit
application dated prior to November 1, 2002, shall be maintained with no openings as
approved. If the approved area separation walls are not maintained, the affected fire
areas, as determined by the Fire Code Official, shall be retrofitted with an approved
automatic fire sprinkler system.
Section 903.1.4 is added to read as follows:
903.1.4 Change of use. Any change of use of a Group U Occupancy, that reclassifies
to a new occupancy classification that would not have been exempt from fire sprinklers
due to existing size, use, fire-flow, access requirements, or distance to a fire station
under a previous Fire District Ordinance in effect at the time the building permit was
issued, shall provide fire sprinklers within the Existing Building. Allowance in Article 3,
Section 903.2 item number 2 shall not apply. This section does not limit the
requirements for fire sprinklers for the new occupancy classification under the current
California Building and Fire Codes.
Section 903.2 is amended to read as follows:
903.2 Where required. Notwithstanding the provisions of Article 3, Sections 903.1.1
through 903.1.4 and 903.2.1 through 903.2.21 an approved automatic fire sprinkler
system shall be installed in Buildings and Structures as follows:
1. An automatic fire sprinkler system shall be installed in all New Buildings.
Exceptions:
A. Group U Occupancies when approved by the Fire Code Official.
Resolution No. 2025-4368
Page 4
B. Small agricultural produce stands as defined and constructed in accordance
with the current edition of the Ventura County Building Code (VCBC) which
comply with all of the following:
1. Floor area of the Structure does not exceed 400 square feet
2. Separated from other Buildings a minimum of 30 feet
C. Picnic and lunch shelter Structures which comply with all of the following:
1. Use is defined as a Group A-2 or A-3 Occupancy by the Building
Department
2. Shall not exceed 1,500 square feet of floor area for an A-2 Occupancy
or 4,500 square feet for an A-3 Occupancy
3. Separated from other Buildings a minimum of 30 feet
4. Only picnic tables and chairs are located underneath the shelter
5. Shall not have any enclosed space underneath the shelter covering
6. Shall be located at grade level around the entire shelter
7. Open on all sides from finished grade to a height of 10 feet above
finished grade
8. Structural columns and other architectural features may not obstruct
more than 10% of the opening length around the Structure
9. Shall have no obstructions that will hinder egress within 10 feet of the
exterior perimeter of the shelter for a distance of 75% of the opening
length around the shelter
10. A food preparation surface area may be located along one opening,
but shall not obstruct more than 20 feet or 10% of the opening length,
whichever is less
11. May be constructed of any materials allowed by the California Building
Code (CBC)
12. Any roof covering shall be non-combustible if not an open trellis style
shelter
D. S-2 Carport Structures which comply with all of the following:
1. Buildings or Structures shall be freestanding and legally separated
from all other Buildings or uses
2. Building shall be constructed of non-Combustible Materials
3. Fire apparatus access shall extend to within 25 feet of all portions of
the interior of the Carport as measured by an approved route around
the exterior of the Building or Structure
Resolution No. 2025-4368
Page 5
2. An approved automatic fire sprinkler system shall be installed in Buildings or
Structures with additions as determined by the following:
A. Additions to legally existing Group R-3 Occupancies, inclusive of attached
Group U Occupancies where the addition is both greater than 1,000 square
feet and greater than 50% of the existing legal Gross Square Feet of the
Structure
B. All occupancies other than Group R-3, where an addition is greater than
25% of the legally existing floor area of the Structure
Exception: Group U Occupancies when approved by the Fire Code Official
C. Where additions to Existing Buildings or Structures increase the allowable
area beyond that permissible in Article 3, Sections 903.2.1 through 903.2.21
for non-sprinklered Buildings
3. Change of use shall require fire sprinklers in accordance with Article 3, Sections
903.2.1 through 903.2.21.
4. Mobile homes, manufactured homes, and multi-family manufactured homes with
up to two dwelling units that are manufactured in accordance with Title 25 of the
California Code of Regulations.
Section 903.3.1.2.3 is amended to read as follows:
903.3.1.2.3 Attics. Attic protection shall be provided as follows:
1. Attics shall be protected by an automatic fire sprinkler system.
Exceptions:
1.1. Attics constructed with only noncombustible materials.
1.2. Attics constructed with only fire-retardant-treated wood complying with
Section 2303.2 of the California Building Code.
1.3. Attics filled with noncombustible insulation.
2. Where fuel-fired equipment is installed in an unsprinklered attic, not fewer than
one quick-response intermediate temperature sprinkler shall be installed above
the equipment.
3. Attics that are used for storage or intended for living purposes shall be protected
by an automatic fire sprinkler system.
Resolution No. 2025-4368
Page 6
ARTICLE 3
APPENDIX B
VCFPD FIRE-FLOW REQUIREMENTS
Section B103.3 is amended to read as follows:
B103.3 Areas without water supply systems. For information regarding water supplies
for fire-fighting purposes in rural areas in which adequate and reliable water supply
systems do not exist, the Fire Code Official is authorized to utilize NFPA 1142 or the
Ventura County Wildland-Urban Interface Code.
Section B103.4 is added to read as follows:
B103.4 Inadequate water purveyors. New Buildings and uses requiring a water
demand, domestic and or fire-flow, shall not be permitted.
ARTICLE 4
Section 604.11 is added to read as follows:
604.11 Fencing.
Section 604.11.1 is added to read as follows:
604.11.1 Scope. This section only applies to fences, including gates within the
fencing, within 5 feet of Building(s), including Decks, (Zone 0) that are in the WUI
area.
Section 604.11.2 is added to read as follows:
604.11.2 New fencing. New fencing and gates installed on or after January 1, 2023,
shall be constructed of a non-combustible material.
Section 604.11.3 is added to read as follows:
604.11.3 Existing fencing. Fencing installed prior to January 1, 2023, may remain.
Exception: The entire fencing not parallel and within 5 feet of the Building, including
gates within the fencing, shall be constructed of a non-combustible material when any
portion of the existing fencing within 5 feet is being replaced. Fencing beyond 5 feet
from the Building is not required to be replaced with non-combustible material.
Resolution No. 2025-4368
Page 7
STATE OF CALIFORNIA )
COUNTY OF VENTURA ) ss.
CITY OF MOORPARK )
CERTIFICATION
I, Ky Spangler, City Clerk of the City of Moorpark, California, do hereby certify
under penalty of perjury that the foregoing Resolution No. 2025-4368 was adopted by the
City Council of the City of Moorpark at a regular meeting held on the 3rd day of December,
2025, and that the same was adopted by the following vote:
AYES: Councilmembers Barrett, Castro, Delgado, Means and Mayor Enegren
NOES: None
ABSENT: None
ABSTAIN: None
WITNESS my hand and the official seal of said City this 4th day of December, 2025.
KyS an l i
it
p , rk
Y
(seal)
OPPPaK eq�4,
Astei!-�'.
nrilr
G�
�4TFU JV~: