HomeMy WebLinkAboutORD 253 1999 0519ORDINANCE NO. 253
AN ORDINANCE OF THE CITY OF MOORPARK CALIFORNIA,
AMENDING TITLE 15 OF THE MOORPARK MUNICIPAL CODE BY
AMENDING CHAPTERS 15.04, 15.08, 15.12, 15.14, 15.16,
15.18, AND 15.20; ADOPTING BY REFERENCE AND AMENDING
THE CURRENT EDITIONS OF CERTAIN MODEL CODES AS FOLLOWS:
UNIFORM BUILDING CODE, VOLUMES 1, 2, & 3, 1997 EDITION;
WITH APPENDIX; NATIONAL ELECTRICAL CODE, 1996 EDITION;
UNIFORM PLUMBING CODE, 1997 EDITION; UNIFORM MECHANICAL
CODE, 1997 EDITION; UNIFORM HOUSING CODE, 1997 EDITION;
UNIFORM CODE FOR THE ABATEMENT OF DANGEROUS BUILDINGS,
1997 EDITION AND THE UNIFORM ADMINISTRATIVE CODE, 1997
EDITION
WHEREAS, Government Code Section §50022.1, et seq., provides
that ordinances and codes of the Federal, State, or any agency of
either of them, may be adopted by reference, provided that prior
to such adoption by reference a notice of public hearing has been
held; and
WHEREAS, a noticed public hearing has been held by the City
Council, at which time all interested persons had the
opportunity to appear and be heard on the matter of adopting by
reference the current editions of certain model codes, as
follows: Uniform Building Code, 1997 Edition, Volumes 1, 2 & 3,
with Appendix; including the Fire Resistive Design Manual,
Fourteenth Edition, dated April 1994; National Electrical Code,
1996 Edition; Uniform Plumbing Code, 1997 Edition; Uniform
Mechanical Code, 1997 Edition; Uniform Housing Code, 1997
Edition; Uniform Code for the Abatement of Dangerous Buildings,
1997 Edition; Uniform Administrative Code, 1997 Edition;
together with amendments thereto.
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF MOORPARK
DOES ORDAIN AS FOLLOWS:
SECTION 1. That Title 15 of the Moorpark Municipal Code is
amended to read as follows:
CHAPTER 15.04
ADMINISTRATIVE PROVISIONS
15.04.010 ADMINISTRATIVE CODE ADOPTED. Except as
hereinafter provided the Uniform Administrative Code, 1997
Edition, published by the International Conference of Building
Officials is hereby adopted by reference as the Administrative
Code of the City of Moorpark. A copy of the Uniform
Ordinance No. 253
Page 2
Administrative Code, 1997 Edition shall be maintained in the
Office of the City Clerk of the City of Moorpark and shall be
made available for public inspection while this Code is in force.
15.04.020 PERMIT FEES. Section 304.2 of the Uniform
Administrative Code is hereby amended to read:
Section 304.2 PERMIT FEES. The fee for each permit shall be
as set forth in the latest resolution of the City Council of the
City of Moorpark relating to permit fees.
The determination of value or valuation under any of the
provisions of these Codes shall be made by the Building Official.
The value to be used in computing the building permit and
building plan review fees shall be the total value of all
construction work for which the permit is issued including all
finish work, painting, roofing, electrical, plumbing, heating,
air - conditioning, elevators, fire- extinguishing systems and any
other permanent equipment.
15.04.030 PLAN REVIEW FEES. Section 304.3 of the Uniform
Administrative Code is hereby amended to read:
Section 304.3 PLAN REVIEW FEES. When a plan or other data
is required to be submitted by Section 302.2, a plan review fee
shall be paid at the time of submitting plans and specifications
for review. The plan review fee shall be as set forth in the
latest resolution of the City Council of the City of Moorpark
relating to plan review fees.
The plan review fees specified in this subsection are
separate fees from the permit fees specified in Section 304.2 and
are in addition to the permit fees. Where plans are incomplete
or changed so as to require additional plan review, an additional
plan review fee shall be charged at the same rate as charged upon
submittal of plans and specifications.
15.04.040 LIABILITY. Section 202.9 of the Uniform
Administrative Code is hereby amended to read:
Section 202.9 LIABILITY. The Building Official, or his
authorized representative charged with the enforcement of this
Code and the technical codes, acting in good faith and without
malice in the discharge of his duties, shall not thereby render
himself personally liable for any damage that may accrue to
persons or property as a result of any act or by reason of any
act or omission in the discharge of his duties. Any suit brought
against the Building Official, agent or employee because of such
act or omission performed by him in the enforcement of any
Ordinance No. 253
Page 3
provision of such Codes or other pert
implemented through the enforcement of
the code enforcement agency shall
jurisdiction until final termination of
judgment resulting therefrom shall
jurisdiction.
:inent laws or ordinances
this Code or enforced by
be defended by this
such proceedings, and any
be assumed by this
The provisions of this section shall apply if the Building
Official or his authorized representatives are employees of this
jurisdiction and shall also apply if the Building Official or his
authorized representatives are acting under contract as agents of
the jurisdiction.
Such Codes shall not be construed to relieve from or lessen
the responsibility of any person owning, operating or controlling
any building, structure or building service equipment therein for
any damages to persons or property caused by defects, nor shall
the code enforcement agency or its parent jurisdiction be held as
assuming any such liability by reason of the inspection
authorized by this code or any permits or certificates issued
under this code.
15.04.050 DISASTER RESPONSE: The City Manager may enter into
mutual aid agreements for emergency Building and Safety Services
for the purpose of assuring adequate and effective response in
the event of earthquake or other unforeseen emergencies.
15.04.060 VIOLATIONS AND PENALTIES.
(a) It shall be unlawful for any person, firm, or
corporation to erect, construct, enlarge, alter, repair, move,
improve, remove, convert or demolish, equip, use, occupy, or
maintain any land, building or structure, building service
equipment, machine or equipment; or cause or permit the same to
be done in violation of this Code or the Technical Codes. Each
such person shall be deemed guilty of a separate offense for each
and every day or portion thereof during which any violation of
any of the provisions of this Code or the Technical Codes is
committed, continued, or permitted.
(b) It shall be unlawful for any person to remove, deface,
alter, or obstruct from view a posted notice of the Building
Official or duly appointed representative when such notice
constitutes a stop work order or a warning of substandard or
hazardous conditions or prohibits or restricts the occupancy or
use of a building, structure, or building service equipment
regulated by this Code or the Technical Codes.
Ordinance No. 253
Page 4
(c) Every violation of this Code or the Technical Codes
shall be deemed a misdemeanor.
(d) Any person convicted of a misdemeanor shall be
punishable by a fine of not more than one thousand dollars
($1,000) or by imprisonment in the county jail for not more than
six (6) months or by both such fine and imprisonment.
CHAPTER 15.08
BUILDING CODE
15.08.010 BUILDING CODE ADOPTED. Except as hereinafter
provided, the Uniform Building Code, 1997 Edition, Volumes 1, 2,
& 3, and Appendix Chapters, 15, except Sections 1517.3 and
1517.4; 29 and 33, including: (1) generic fire - resistive
assemblies listed in the Fire Resistance Design Manual,
Fourteenth Edition, dated April 1994, published by the Gypsum
Association as referenced in Tables 7 -A, 7 -B and 7 -C (2) Appendix
Chapter 3, Divisions I, II and IV; (3) Appendix Chapter 4,
Division II and III, 9, 10, 12 Divisions I; (4) Appendix Chapters
7,9,10 and 11; (5) Appendix Chapter 12 Division II; (6) Appendix
Chapter 15, 18, 21, 23, 30 including ANSI /ASME A17.1, 1987 Safety
Code for Elevators and Escalators, including supplements A17.1a-
1988, A17.1b -1989, and to ANSI /ASME A 17.3a -1986, Safety Code for
Existing Elevators an Escalators, including Supplements A17.3a-
1989, published by the American Society of Mechanical Engineers;
and (7) 31, 33 and 34; and (8) Structural Welding Code -
Reinforcing Steel, AWS D1.4 -92 (UBC Standard 19 -1); (9) Load and
Resistance Factor Design Specifications for Structural Steel
Buildings, December 1, 1993 (Chapter 22, Division II); (10)
Specification for Structural Steel Buildings Allowable Stress
Design and Plastic Design, June 1, 1989 (Chapter22, Division
III); (11) Load and Resistance Factor Design Specification for
Cold Formed Steel Structural Members, 1986 (with December, 1989
Addendum) (Chapter 22, Division VI); (12)Specification for Design
of Cold - Formed Steel Structural Members, 1986 (Chapter 22,
Division VII); (13) Standard Specification for Steel Joists, K-
Series, LH- Series, DLH- Series and Joist Girders, 1994 (Chapter
22, Division IX); (14) Structural Applications of Steel Cables
for Buildings, ASCE 17 -95 (Chapter 22, Division XI); and (15)
National Design Specification for Wood Construction, Revised 1991
Edition (Chapter 22, Division III, Part I), are hereby adopted by
reference as the Building Code of the City of Moorpark. A copy
of the Uniform Building Code, 1997 Edition, Volumes 1, 2, & 3,
and the various appendices thereto, shall be maintained in the
office of the City Clerk in the City of Moorpark, and shall be
made available for public inspection while this Code is in force.
Ordinance No. 253
Page 5
15.08.020 ADMINISTRATIVE PROVISIONS DELETED. The
Administrative Provisions of the Uniform Building Code, 1997
Edition, contained in Volume 1 of that Code except Sections 101.1
and 101.2 are hereby deleted. The Administrative provisions
governing the Building Code, including violation and penalty
provision, shall be as set forth in Chapter 15.04 of the
Municipal Code of the City of Moorpark.
15.08.030 FOUNDATION DESIGN. Section 1804.7.1 is hereby
added and TABLE 18 -I -C is hereby amended to read:
Section 1804.7.1. When buildings are located on expansive
soil having an expansion index greater than 50, gutters,
downspouts, piping, and /or other non - erosive devices shall be
provided to collect and conduct rain water to a street, storm
drain, or other approved watercourse or disposal area.
Ordinance No. 253
Page 6
Table 18 -I-C— - -.-Foundations for stud bearing walls - -- minimum requirements" 10,11•12
Weighted
Foundation for slab and raised floor systems•'•'
Concrete slabs
Expansion
Index
Pre- morsteneing
of soils under
Restrictions
on
piers under
No. of
stories
Stem
Thickness'
Footing
Width
Footing
Thickness
All perimeter
Footings `
Interior
footings
for slab and
Reinforcement 3 -1/2" minimum thickness
for 4" with E.I. over 51
continuous
raised
floors'
Foundations Reinforcement Total
'•�
footings, piers
raised floors
Thickness
and slabs`''
Depth helow natural surface
Of ground and finish grade
of sand
Inches
0 -20
Very low
1
2
6 12 6 12 12
6 15 7 le 18
1 -64 04 8 48"
o /c..
Top and each way 2"
Moistening of ground
prior to placing concrete
Piers allowed
singled floor
Non expansive
3
30 18 8 24 24
Bottom or
1 -04 43 0 36"
° /c••
Top and each way 4"
is recommended
loads only
21 -50
Low
1
2
6
8
12
15
6
7
15
18
12
18
3r, over optimum moisture required
to a depth of 18" below lowest
Piers allowed
for
single floor
3
10
18
8
24
24
Bottom
adjacent
grade. Testing required.
loads only
51 -90
1
6
12
8
21
12
1 -04 top 03 P 24" o.c.
38 over opt.imim moisture required
Medium
2
8
15
8
21
18
and bottom each way 4"
to a depth of 18" below lowest
Piers not
3
30
18
8
24
24
73 bars P 24" o.c. each way
ed3acent
grade. Testing required.
allowed
12" into footing, 36" into
91 -130
1
6
12
8
27
12
slab "
2- Y4 Y3 Q 24" o.c.
3k over optimum moisture required
High
2
8
15
8
27
18
Top t bottom each way 4"
to a depth of 18" below lowest
Piers not
3
30
18
6
27
24
03 bars Q 24" o.c. each way
adjaent
grade. Testincg required.
allowed
12" into footing, 36" into
Above 130
slab '
Special design by a licensed Architect or Engineer required
Very high
Ordinance No. 253
Page 7
FOOTNOTES TO TABLE UBC 18 -I -C
1. Premoistening is required where specified in Table UBC 18 -I-
C in order to achieve maximum and uniform expansion of the
soil prior to construction and thus limit structural
distress caused by uneven expansion and shrinkage. Other
systems, which do not include pre- moistening, may be
approved by the Building Official, when such alternatives
are shown to provide equivalent safeguards against the
adverse effects of expansive soil.
2. Underfloor access crawl holes shall be provided with curbs
extending not less than six (6) inches above adjacent grade
to prevent surface water from entering the foundation area.
3. Reinforcement for continuous foundations shall be placed not
less than 3" above the bottom of the footing and not less
than 3" below the top of the stem.
4. Slab reinforcement shall be placed at mid -depth and continue
to within two inches of the exterior face of the exterior
face of the exterior footing walls.
5. Moisture content of soils shall be maintained until
foundations and piers are poured and a vapor barrier is
installed. Test shall be taken within 24 hours of each
slab pour.
6. Crawl spaces under raised floors need not be premoistened
except under interior footings. Interior footings which are
not enclosed by a continuous perimeter foundation system or
equivalent concrete or masonry moisture barrier complying
with Section UBC 1806.3 in this ordinance shall be designed
and constructed as specified for perimeter footings in Table
UBC 18 -I -C.
7. A grade beam not less than 12" X 12" in cross - sectional
area, reinforced as specified for continuous foundations in
Table UBC 18 -I -C, shall be provided at garage door openings.
8. Foundation stem walls which exceed a height of three times
the stem thickness above lowest adjacent grade shall be
reinforced in accordance with Sections 18 and 19 in the UBC,
or as required by engineering design, whichever is more
restrictive.
9. Footing widths may be reduced upon submittal of calculations
by a registered civil or structural engineer or licensed
architect, but shall be a minimum of 12 inches for one and
Ordinance No. 253
Page 8
two -story structures and 15 inches for three -story
structures.
10. Bent reinforcing bard between exterior footing and slab
shall be omitted when floor is designed as an independent,
"floating" slab.
11. Fireplace footings shall be reinforced with a horizontal
grid located 3" above the bottom of the footing and
consisting of not less than No. 4 bars at 12" on center each
way. Vertical chimney reinforcing bars shall be hooked
under the grid.
12. Underground utility conduits shall be installed prior to
foundation inspection and shall extend beyond the foundation
so that final connection will not undermine the finished
foundation.
15.08.040 PLYWOOD DESIGN. TABLE 23- II -I -1 is hereby
amended to read:
ordinance No. 253
Page 9
Table 23- II -I -1 Allowable shear for wind or seismic forces in pounds per square foot for wood structural panel shear
walls with framing of Douglas fir -larch or Southern ine'2,7
Panel grade
Minimum
Minimum
nail
Panels applied directly to framing
Panels applied over 112 inch (13mm) or 5/8 inch (16mm)
Nominal
panel
Penetration
sum sheathing
Neil spacing at panel edges (inches)
Nall s acin
P 9 et panel edges (inches)
thickness
in framing
Neil size
Nail size
X 25.4 for mm
x 25.4 for mm
(inches)
(inches)
(Common or
(Common or
6
4 j
3
2
6
4
1 3
2
Galvanized
box)
galvanized
box)
x 25.4 for mm
x 0.0146 for N /mm
x 0.0146 for N /mm
5/16"
1 1 /4"
6d
200
300
390
510
8d
200
300
390 6
510
Structural 1
3/8"
230
360
460
610 '
1 112"
8d
lod '
280
430 `
550 1
730 "
7/16"
255
395
505
670
15/32"
280
430
550
730
15/32"
1 5/8"
10d
340
510
665
870
_
5/16"
1 1 /4"
6d
180
270
350
450
8d
180
270
350
450
C -D, C -C
3/8"
200
300
390
510
200
300
390
510
Sheathing,
plywood
3/8"
220
720
410 •'
530
Panel siding and
other
1 112"
8d
10d
260
300 `
490 `
640 '
7/16"
240
350
450
585
Grades covered in
U.B.C.
15/32"
260
380
490
640
Standard 23 -2 or
23 -3
15/32"
1 5/8"
10d
310 -
460
600
770
19/32"
340
51.0
665
870
Plywood panel
Neil size
(galvanized
casing)
Nail size
(galvanized
casing)
siding
In grades 5/16" 1 1/4"
6d
140 210 275 360 `
8d
140 210 275 360 '
Covered in U.B.C.
Standard 23 -2 318" 1 112"
8d
160
240
310
410 `
10d
160
240
310 `
410 `
All panel edges backed with 2 -inch (51mm) nominal or wider framing. Panels installed either horizontally or vertically. Space nails at 6 inches(152 mm) on center along
intermediate framing members for 3/8 -inch (9.5mm) and 7/16 -inch (11 mm) panels installed on studs spaced 24 inches (610 mm) on center and 12 inches (305 mm) on center for
other conditions and panel thickness'. These values are for short time loads due to wind or earthquake and must be reduced 25 percent for normal loading.
Allowable shear values for nails in framing members of other species set forth in Table 23- III -FF of Division III shall be calculated for all other grades by multiplying the
shear capacities for nails in Structural 1 by the following factors: 0.82 for species with specific gravity greater than or equal to 0.42 but less than 0.49, and 0.65 for
species with a specific gravity less than 0.42.
Where panels are applied on both faces of a wall and nail spacing is less than 6 inches (152 mm) on center on either side, panel Joints shall be offset to fell on different
framing members or framing shall be 3 inch ('16 mm) nominal or wider
and nails on each side shall be staggered.
Framing at adjoining panel edges shall be 3 inch (76 mm) nominal or wider and nails shall be staggered where nails are spaced 2 inches (51 mm) on center.
The values for 3/8 -inch (9.5 mm) and 7/16 -Inch (11 mtn) panels applied direct to framing may be Increased to the values shown for 15/32 -inch (12 mm) panels, provided studs are
spaced a maximum of 16 (406 mm) inches on center and panels are applied with long dimensions across studs.
Framing at ad7ntning panel edges shall be 3 inch (76 "1 nominal or wider and nails shall be staggered where 10d nails having penetration into framinq of more than 1 5/8
inches (41 mm) are spaced 3 inches (76 mm) or less on center.
For plywood shear walls raLed at more than 300 pounds per foot, 3 inch (76 mm) nominal members shall be provided at All panel edges And boundaries. The minimum edge distance
for nailing at Lhese members shall be 1/2 -inch.
The shear values listed in this table shall be reduced to 75 percent for short term seismic loading.
Ordinance No. 253
Page 10
15.08.050 HOLD -DOWN CONNECTORS. Section 2315.5.6 is
hereby added to read:
Section 2315.5.6 Hold -down connectors. Hold -down connectors
shall be designed to resist shear wall overturning moment using
approved cyclic load values or 75 percent of the allowable
earthquake load values that do not consider cyclic loading of the
product.
15.08.060 HEIGHT TO LENGTH RATIO,. Section 2513.4 is
hereby added to read:
Section 2513.4. The maximum allowable height to length ratio
for the construction in this section shall be limited to one
� 1 �
15.08.70 TABLE 25 -I of the Uniform Building Code is hereby
amended to read:
Ordinance No. 253
Page 11
TABLE 25 -1 ALLOWABLE SHEER FOR WIND OR SEISMIC FORCES IN POUNDS PER FOOT FOR VERTICAL
DIAPHRAGMS OF LATH Amn PT.Aq'rPP nR r_v Dcrim mnnon mii-A rT, t.TTTT
TYPE OF MATERIAL
THICKNESS OF
WALL
NAIL SPACING
[2]
[1LL n..JVLL'1
SHEAR VALUE
LJLI LJ L 1 J
MINIMUM NAIL SIZE [3] [4]
MATERIAL
CONSTRUCTION
MAXIMUM
Seism
Wind
is
(In inches)
[5]
]6]
1. Expanded
metal, or
woven wire lath
and
Portland cement
Plaster [7]
7/8"
Unblocked
6
90
180
No. 11 gage, 1 -1/2" long,
7/16" head,
galvanized with a 1/4" nail
furring pad
required for woven wire.
2. Gypsum lath
3/8" lath and
Unblocked
5
30
100
No. 13 gage, 1 -1/8" long,
1/2" plaster
19/64" head
plasterboard - point, galvanized
3. Gypsum
wallboard or
Veneer base
1 /2 "x 2'x8'
Unblocked
4
30
75
No. 11 gage, 1 -3/4" long,
17/16" head,
diamond - point, galvanized
1/2" x 4'
1/2" x 4'
Blocked
Unblocked
4
7
30
30
175
4. Gypsum
wallboard or
1/2"
7
30
60
5d cooler or wallboard
Unblocked
Veneer base
4
30
125
Blocked
7
30
125
4
30
150
5/8"
6d cooler or wallboard
Unblocked
7
30
115
4
30
145
Blocked
7
30
145
4
30
175
Base ply- 6d cooler or
Blocked
Base ply: 9
30
250
wallboard
Two ply
Face ply: 7
Face ply- 8d cooler or
wallboard
1. These vertical diaphragms
shall not be used to reslst
loads lmbosen by masnnry
nr
-- -... --- ------•• --' -•--
u , o v t Value' must be king. reduced 25 percent for nurmal loaning.
2. Applies to nailing at all studs, lop and bottom plates and blocking.
3. Alternate nails may be Used It their dimensions are Not ic55 than the soccifled dimensions.
4. For properties of cooler o wallooaro nails, sec 2340 .1.2
5. Thls Construction shall only be used i n the tup level of a multi -level bulld:ngs.
6. This 'axlmum height to le r.grn ratio for shear va115 const meted of these mate a als shall not exceed one (1).
7. Self -f utting Lath attached .1rh ntaplrn may be perm i'Led for non-s tructu ral application only.
Ordinance No. 253
Page 12
15.08.090 FIRE HAZARD ZONE REQUIREMENTS. Chapter 36 is
hereby added to the Uniform Building Code to read:
CHAPTER 36
FIRE HAZARD ZONE REQUIREMENTS
Sec. 3601. HIGH FIRE HAZARD AREA DEFINED. For the purpose
of this code, certain locations within the incorporated areas of
the City of Moorpark shall be classified as High Fire Hazard by
the Ventura County Fire Protection District. The High Fire
Hazard Area is defined as any area within 500 feet of
uncultivated brush, grass, or forest - covered land wherein an
authorized representative of said district determines that a
potential fire hazard exists due to the presence of such
flammable growth.
Sec. 3602. CONSTRUCTION REQUIREMENT IN HIGH FIRE HAZARD
AREAS. The purpose of this Section is to provide a minimum
standard for the fire protection of buildings and structures
hereafter erected in proximity to areas of the City where
concentrations of highly flammable brush, grass, or other
combustible growth combined with periods of hot, dry winds create
a high fire hazard and where lives and property may thereby be
endangered.
Buildings or structures hereafter erected, constructed or
moved within or into designated high fire hazard areas shall be
one of the Types of Construction as defined in this Code and
shall meet the requirements of this Section. Although their
installation is encouraged, neither manual nor automatic fire
extinguishing systems or similar water spraying devices may be
substituted for the fire protection set forth herein.
3602.1 ROOFS.
specified in Section
that no wooden shakes
oermitted.
Roof coverings shall
1504 of the Uniform
or shingles, treated
be class A, or B as
Building Code, except
Dr untreated, shall be
3602.2 EXTERIOR WALLS. Fire - resistive protection of
exterior walls and openings, as determined by location and
property, shall be as required by Section 503 in the UBC.
Exception: No exterior wall covering of a building shall provide
less fire resistance than that afforded by; 7/8 -inch exterior
cement plaster; 1 -inch nominal thickness solid wood siding; 1/2-
inch textured plywood siding having a groove depth of 1/8 -inch or
less; 7/16 -inch hardwood siding 5/8 inch particle board, exterior
type 2 -M; or 5/8 exterior plywood, Texture III, having a groove
depth of 1/4 -inch or less. Fire - retardant treated or untreated
wood shingle or shake siding shall not be permitted.
Ordinance No. 253
Page 13
3602.3 UNDERFLOOR AREAS. Where under floor areas are not
enclosed by fire- resistive construction conforming to the
requirements of Section 3601.2 above, the underside of the floor
system shall be fire - protected as set forth in Section 3601.4.
3602.4 PROJECTIONS AND OTHER BUILDING ELEMENTS EXPOSED TO
FIRE. Architectural projections such as roof overhangs and
offsets, balconies and decks, and other elements of buildings
which have combustible structural elements in the horizontal
plane, shall be protected with materials approved for 1 -hour
fire - resistive construction on the lower, fire - exposed side and
shall have 1 -hour fire - resistive supporting columns unless the
details of construction conform to those for heavy timber as
described in Section 605.6 in the UBC.
Exceptions:
1. Combustible structural members in horizontal projections
may be unprotected timbers of size 4x6 or larger when used as
rafters or as stair, balcony, or deck supports or for similar
purposes.
2. Heavy timber roof decking at eaves and rakes may be
unprotected provided a fascia of not less than 2 -inch nominal
thickness and not less in depth than the cut end of the rafter is
installed at the roof's edge.
3. Patios, carports, arbors and open latticework sunshades
may be constructed of any materials allowed by this Code.
4. Balconies and decks 30 inches or more above grade may
have flooring of not less than 2 -inch nominal thickness lumber or
material of equivalent fire resistance. Such flooring may be
spaced not more than 1/4 inch apart and need not be fire
protected on the underside.
5. Balconies and decks less than 30 inches above grade
shall be solidly floored without gaps and shall be fire - protected
on the underside as required by this Section. In lieu of fire
protection, such balconies and decks may be enclosed from floor
surface to grade in the manner prescribed for exterior walls in
Section 3602.2.
6. Combustible exterior columns directly supporting roofs,
stairs, balconies, and decks may be size 4x4 or larger. Columns
and beams supporting interior floor loads may be size 6x6 or
larger.
Ordinance No. 253
Page 14
3602.5 VENTILATION OPENINGS. Attic or foundation
ven�ilation openings or louvers shall not be located at or
immediately below, eaves, or rakes, offsets or balconies, or
similar exterior overhangs which may be directly exposed to a
fire in adjacent hazardous grass or brush areas.
Section 3603. WAIVER OF REQUIREMENTS. The Building
Official may waive the requirements of UBC Sec. 3601.1 through
3602.5 above, in whole or in part, for specific construction
projects within the High Fire Hazard Area when such waiver is
approved by an authorized representative of the Ventura County
Fire Protection District, based upon site conditions which
justify a reduction in fire resistance.
15.08.090 FOUNDATION INVESTIGATION. Section 1804.2 and
1804.7 are hereby amended to read:
Section 1804.2 INVESTIGATION. The classification of soil
shall be based on observation and necessary tests of the
materials disclosed by borings or excavations made in appropriate
locations. Additional studies may be required to evaluate soil
strength, the effect of moisture variation on soil bearing
capacity, compressibility, liquefaction and expansiveness.
Whenever, in the opinion of the Building Official, the
adequacy and stability of a building site cannot be determined by
the test borings or excavations required by this Section, he may
require a special geologic, hydrologic, seismic, or other
investigation and report. Geologic investigations such as those
for hillside stability or seismic hazards shall be conducted by
California- certified Engineering Geologist.
Section 1804.7 Drainage provisions shall be made for the
control and drainage of surface water around buildings. The
Building Official may require that all storm and excess
irrigation water be directed to a street storm drain, natural
drainage course, or other approved location in approved non -
erosive devices.
15.08.100 GRADING ENFORCEMENT BY CITY ENGINEER. The
definition of Building Official contained in Section 203 of the
Building Code is hereby amended to read:
Section 203 BUILDING OFFICIAL. Is the officer or other
designated authority charged with the administration and
enforcement of this Code, except Appendix Chapter 33, or his duly
authorized representative. The Authority designated to enforce
Appendix Chapter 33 shall be the City Engineer.
Ordinance No. 253
Page 15
15.08.110 SWIMMING POOLS. CHAPTER 37 is hereby added to the
Uniform Building Code to read:
CHAPTER 37
SWIMMING POOLS
Section 3701 DEFINITIONS. For the purpose of this Article
certain terms are hereby defined as follows:
"Pool" shall mean any body of water created by artificial
means which is designed or used for swimming or immersion
purposes by men, women, or children and which has a water depth
exceeding twenty -four (24) inches. The term "pool" shall include
swimming pools, spas, hot tubs and above and below ground vinyl -
lined pools but does not apply to plumbing fixtures such as
bathtubs; nor does it apply to man -made lakes, reservoirs, or
farm ponds used primarily for public park purposes, water
conservation, irrigation, or watering of livestock.
Section 3702 POOL DESIGN AND CONSTRUCTION.
3702.1 GENERAL. Pool design and construction shall be in
accordance with accepted engineering practice, shall be in
conformity with applicable provisions of the adopted building,
electrical, plumbing, and mechanical codes, and shall be
structurally suitable for the soil, topographic, and geologic
conditions prevailing at the construction site.
3702.2 EXPANSIVE SOIL DESIGN. Pools constructed at grade
shall be designed on the assumption that their construction is to
be in an area of moderately expansive soil having an expansion
index of 51 -90 and an equivalent fluid pressure of not less than
45 pounds per cubic foot (45 p.c.f.). Exception: Where tests
indicate that soils at a pool site are non - expansive or have low
expansion characteristics from the ground surface to the full
depth of the pool, structural design may be based on an
equivalent fluid pressure not less than 30 p.c.f.
In highly expansive soils having an expansion index of 91-
130, pools shall be designed for not less than 60 p.c.f.
equivalent fluid pressure. In very highly expansive soils having
an expansion index over 130, pool design shall be subject to
special requirements based on a site investigation, soil testing,
and engineering analysis by a registered civil engineer to
determine appropriate design parameters for the site.
3702.3 HYDROSTATIC UPLIFT. In areas of anticipated high
water table, an approved hydrostatic relief system or device
shall be installed.
Ordinance No. 253
Page 16
3702.4 THERMAL PROTECTION FOR PLASTIC PIPING. Between the
inlet of pool water heating equipment and any plastic water
piping connected thereto, a check valve shall be installed to
prevent thermal damage to such piping due to backflow.
Exception: When rapid or high -rate filters are employed, a check
valve may be omitted. Between the outlet of pool heating
equipment and any plastic water piping connected thereto, not
less than five feet of approved metal pipe shall be installed for
the purpose of dissipating heat.
3702.5 SAFEGUARDING SUCTION DRAINS. Bottom drains and
suction intakes in pools and spas shall be covered with grated or
other protective devices which cannot be removed except with
tools. The slots or openings in these covers shall be of such
area, shape, and arrangement as to prevent bathers from being
drawn thereto with such force as to constitute a safety hazard.
3702.6 GRAB BARS. Wherever egress from a pool by bathers
is restricted by the presence of a vertical wall or other barrier
which extends more than 12 inches above the water at the pool's
edge, permanent handrail, grab bars, or equivalent device(s)
shall be installed within 12 inches of the water surface, capable
of being securely grasped and adequate to support the weight of a
user of the pool.
Section. 3703 DECKS
3703.1 GENERAL. A deck shall be provided around below -
grade swimming pools except when special engineering design is
furnished which indicates that such deck is not necessary for the
purpose of maintaining the structural integrity of the pool
and /or for controlling surface water and moisture content in the
soil adjacent to the pool. Decks shall not be required for spas
and hot tubs.
3703.2 DECK DESIGN AND CONSTRUCTION. Required decks shall
be constructed of concrete or other approved impervious material
and shall be sloped to provide positive drainage away from the
perimeter of the pool. Except as provided below, decks shall
have a minimum width of four feet and shall be at least 3 -1/2
inches in thickness. Reinforcement shall be #3 bars spaced not
over 24 inches o.c. each way, or equivalent reinforcing.
Approved joints shall be provided in the deck at corners, at
maximum 10 -foot intervals, and wherever necessary in order to
control cracking, to allow for differential movement and to
minimize damage to the deck from such movement should it occur.
Ordinance No. 253
Page 17
Joints in decks and coping shall be made watertight with an
approved permanent resilient sealant.
3703.3 CUTOFF WALLS. At the outer perimeter of pool decks
a cutoff wall of approved material shall be installed below -grade
to a depth of at least 15 inches so as to form a permanent and
effective vertical moisture barrier.
Exception:
1. A cutoff wall may be omitted when a deck at least six
feet wide is installed.
2. Decks less than four feet in width may be installed
provided that the required cutoff wall is increased in depth
beyond the minimum by an amount directly proportional to the
reduction in deck width.
3703.4 PRE - SATURATION, HIGHLY EXPANSIVE SOILS. When the
soil below a deck has an expansion index of 91 or greater it
shall be saturated with water to a depth of at least 18 inches
prior to installation of the deck.
Section 3704. DRAINAGE AND DISPOSAL
3704.1 SURFACE WATER. Surface water from pool decks shall
be collected and conducted through non - erosive devices to a
street, storm drain, or other approved watercourse or disposal
area.
3704.2 WASTEWATER. Pool waste shall be disposed of in
accordance with the requirements of the Health Officer.
3704.3 DRYWELLS. Drywells shall not be employed for pool
wastewater disposal except when specifically approved for the
purpose and when it has been determined that such installation is
not likely to have adverse effects on the structural stability of
the pool or other structures on the site. The Building Official
may require a percolation test, soils report, and /or geological
report to make such a determination.
Section. 3705. SPECIAL INSPECTION. Special inspection as
required by Section 1701 in the UBC shall be provided for
pneumatically placed concrete (gunite) in swimming pools.
Section. 3706. FENCING AND GATES. Any person, firm, or
corporation in possession of land either as owner in fee,
purchaser under contract, lessee, tenant, licensee or any type of
legal estate upon which is situated a pool as defined above shall
Ordinance No. 253
Page 18
at all times maintain on the lot or premises a fence or wall not
less than five feet in height which completely surrounds such
pool or body of water provided, however, that a dwelling or
accessory building may be used as a part of such enclosure. Said
fence shall be constructed of durable material and shall be
designed to withstand a horizontal force of at least 20 pounds
per lineal foot at the top of the fence or top of the railing.
Openings, holes, or gaps therein shall be no larger than four (4)
inches wide except for openings closed by doors or gates. Fences
shall not have a configuration which provides a ladder -like
access to the pool area.
Each gate or door opening through a pool enclosure shall be
equipped with a self- closing and self - latching device capable of
keeping the gate or door securely closed at all times when not in
use.
Exceptions:
1. Doors in Group R, Division 1 and 3 occupancies which form
part of a pool enclosure.
2. Gates used primarily for ingress and egress of equipment
but not persons to the pool area, and which are kept padlocked
when not in use.
Required latching devices shall be installed not less than
four feet above ground level and on the waterside of the gate.
The Building Official may make modifications and accept
alternatives to the fencing requirements in individual cases upon
a showing of good cause with respect to the height, nature or
location of the fence, wall, gates, or latches, or the necessity
therefore, provided that protection is not reduced thereby.
CHAPTER 15.12
ELECTRICAL CODE
15.14.010 ELECTRICAL CODE ADOPTED, except as hereinafter
provided, the National Electrical Code, 1996 Edition, published
by the National Fire Protection Association is hereby adopted by
reference as the Electrical Code of the City Of Moorpark. A copy
of the National Electrical Code, 1996 Edition, shall be
maintained in the office of the City Clerk of the City Of
Moorpark and shall be made available for public inspection while
this Code is in force.
15.14.020 ADMINISTRATIVE PROVISIONS DELETED. The
Administrative Provisions governing the Electrical Code,
Ordinance No. 253
Page 19
including violation and penalty provisions shall be as set forth
in Chapter 15.04 of the Municipal Code of the City of Moorpark.
CHAPTER 15.14
PLUMBING CODE
15.14.010 PLUMBING CODE ADOPTED. Except as hereinafter
provided, the Uniform Plumbing Code, 1997 Edition, published by
the International Association of Plumbing and Mechanical
Officials, is hereby adopted by reference as the Plumbing Code of
the City of Moorpark. A copy of the Uniform Plumbing Code 1997
Edition, shall be maintained in the office of the City Clerk of
the City of Moorpark and shall be made available for public
inspection while this Code is in force.
15.14.020 ADMINISTRATIVE PROVISIONS DELETED. The
Administrative provisions of the Uniform Plumbing Code, 1997
Edition, contained in Volume 1 of that Code except sections 101.1
and 101.2 are hereby deleted. The Administrative provisions
governing the Plumbing Code, including violation and penalty
provisions, shall be as set forth in Chapter 15.04 of the
Municipal Code of the City of Moorpark.
15.14.030 Section 202.0 DEFINITIONS is hereby amended to
read:
Section 202.0. SEMI - PUBLIC- Semi - public shall be defined as
a building, swimming pool or area serving more than one person
but not available to the general public.
15.14.030 FLOOR DRAINS REQUIRED is hereby added to the
Uniform Plumbing Code to read:
Section 411.1 In restrooms adjacent to semi - public swimming
pools, a minimum of one (1) floor drain shall be provided in each
restroom for each sex. Floor drains shall be connected to the
public sewer in accordance with Section 305.1 of this Code. The
traps serving these floor drains shall be installed in accordance
with Sections 1006.0 and 1007.0 of this Code.
Ordinance No. 253
Page 20
CHAPTER 15.16
MECHANICAL CODE
15.16.010 MECHANICAL CODE ADOPTED, except as hereinafter
provided, The Uniform Mechanical Code, 1997 Edition, published by
the International Conference of Building Officials, is hereby
adopted by reference as the Mechanical Code of the City of
Moorpark. A copy of the Uniform Mechanical Code, 1997 Edition
shall be maintained in the office of the City Clerk of the City
of Moorpark and shall be made available for public inspection
while this Code is in force.
15.16.020 ADMINISTRATIVE PROVISIONS DELETED. The
Administrative provisions of the Uniform Mechanical Code, 1997
Edition, contained in Volume 1 except sections 101.1 and 101.2
are hereby deleted. The Administrative Provisions governing the
Mechanical Code, including violation and penalty provisions,
shall be as set forth in Chapter 15.04 of the Municipal Code of
the City of Moorpark.
CHAPTER 15.18
HOUSING CODE
15.18.010 HOUSING CODE. Except as hereinafter provided the
Uniform Housing Code, 1997 Edition, published by the
International Conference of Building Officials, is hereby adopted
by reference as the Housing Code of the City of Moorpark. A copy
of the Uniform Housing Code, 1997 Edition, shall be maintained in
the office of the City Clerk of the City of Moorpark and shall be
made available for public inspection while this Code is in force.
15.18.020 SUBSTANDARD BUILDINGS. Chapter 10 of the Uniform
Housing Code is amended to read as set forth in Section §17920.3
of the Health and Safety Code of the State of California. A Copy
of Section §17920.3 of the Health and Safety Code of the State of
California shall be maintained in the office of the City Clerk of
the City of Moorpark and shall be made available for public
inspection while this Code is in force.
15.18.030 ADMINISTRATIVE PROVISIONS. The Administrative
Provisions governing the Mechanical Code, including violation and
penalty provisions, shall be as set forth in Chapter 15.04 of the
Municipal Code of the City of Moorpark.
Ordinance No. 253
Page 21
CHAPTER 15.20
DANGEROUS BUILDINGS
15.20.010 DANGEROUS BUILDING CODE ADOPTED. Except as
hereinafter provided, the Uniform Code for the Abatement of
Dangerous Buildings, 1997 Edition, is adopted as the Dangerous
Buildings Code of the City of Moorpark. A copy of the Uniform
Code for the Abatement of Dangerous Buildings, 1997 Edition shall
be maintained in the office of the City Clerk of the City of
Moorpark and shall be made available for public inspection while
this Code is in force
15.20.020 ADMINISTRATIVE PROVISIONS. The Administrative
Provisions governing the Mechanical Code, including violation and
penalty provisions, shall be as set forth in Chapter 15.04 of the
Municipal Code of the City of Moorpark.
SECTION 2. AMENDMENTS NECESSARY. Pursuant to Section
§17958.5 of the Health and Safety Code of the State of
California, The City Council of the City of Moorpark hereby finds
that the amendments of the Uniform Building Code, 1997 Edition,
Uniform Plumbing Code, 1997 Edition, Uniform Mechanical Code,
1997 Edition, and National Electrical Code, 1996 Edition, made by
this Ordinance are reasonably necessary due to local climatic,
geological, or topographical conditions.
SECTION 3. If any section, subsection, sentence, clause,
phrase, part or portion of this Ordinance is for any reason held
to be invalid or unconstitutional by any court of competent
jurisdiction, such decision shall not affect the validity of the
remaining portions of this Ordinance. The City Council declares
that it would have adopted this Ordinance and each section,
subsection, sentence, clause, phrase, part or portion thereof,
irrespective of the fact that any one or more sections,
subsections, sentences, clauses, phrases, parts or portions be
declared invalid or unconstitutional.
SECTION 4. This Ordinance shall become effective thirty
(30) days after its passage and adoption.
SECTION 5. The City Clerk shall certify to the passage and
adoption of this ordinance by not less than a four - fifths vote of
the City Council; shall enter the same in the book of original
ordinances of said City; shall make a minute of the passage and
adoption thereof in the records of the proceedings of the City
Council at which the same is passed and adopted; and shall,
Ordinance No. 253
Page 22
within fifteen (15) days after the passage and adoption thereof,
cause the same to be published in the manner prescribed by law.
PASSED AND ADOPTED this 2 "d day of June, 1999.
ATTEST:
Deborah S. Traffens edt, City Clerk
Ordinance No. 253
Page 23
STATE OF CALIFORNIA )
COUNTY OF VENTURA )
CITY OF MOORPARK )
ss.
I, Deborah S. Traffenstedt, City Clerk of the City of Moorpark,
California, do hereby certify under penalty of perjury that the
foregoing Ordinance No. 253 was adopted by the City Council of
the City of Moorpark at a meeting held on the 19th day of May,
1999, and that the same was adopted by the following vote:
AYES: Councilmembers Evans, Harper, Rodgers, Wozniak,
and Mayor Hunter
NOES. None
ABSENT: None
ABSTAIN: None
WITNESS my hand and the official seal of said City this 26th day
of May, 1999.
Deborah S. Traffens edt, City Clerk
(seal)