Loading...
HomeMy WebLinkAboutRES 1998 357 0622RESOLUTION NO. PC -98 -357 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF MOORPARK, CALIFORNIA, RECOMMENDING TO THE CITY COUNCIL APPROVAL OF INDUSTRIAL PLANNED DEVELOPMENT PERMIT NOS. 98 -1, 98 -2 ON THE APPLICATION OF JERROLD S. FELSENTHAL, TRUSTEE FOR THE JERROLD S. FELSENTHAL TRUST AND INDUSTRIAL PLANNED DEVELOPMENT PERMIT NO. 98 -3 ON THE APPLICATION OF J AND L INVESTMENTS FOR CONSTRUCTION OF THREE INDUSTRIAL BUILDINGS LOCATED ON LOTS 1, 2 AND 3, TRACT NO. 3492 ON CONDOR DRIVE (ASSESSOR PARCEL NOS. 513 -0- 060 -275, (LOT 1), 513 -0- 060 -285 (LOT 2) AND 513 -0- 060 -035 (LOT 11) WHEREAS, at a duly noticed public hearing on June 22, 1998, the Planning Commission held a public hearing and conditionally recommended to the City Council approval of Industrial Planned Development Permit Nos. 98 -1, 98 -2 on the application of Jerrold S. Felsenthal, trustee for the Jerrold S. Felsenthal Trust and IPD 98 -3 on the application of J and L Investments for construction of three industrial buildings located on lots 1, 2 and 3, Tract No. 3492 along Condor Drive (Assessor Parcel Nos. 513 -0- 060 -275, (lot 1), 513 -0- 060 -285 (lot 2) and 513 -0- 060 -035 (lot 3) as follows: Industrial Planned Development Permit_.NQ-_90 -]. A two story 21,000 square foot (18,000 square foot first floor) , 3,000 square foot second floor) manufacturing warehouse building with parking and landscaping, located on Lot No. 2 of Tract 3492, Assessor Parcel No. 513 -0- 060 -285. Industrial Planned Development-No---9-&--2 A two story 21,000 square foot (18,000 square foot first floor), 3,000 square foot second floor) manufacturing warehouse building with parking and landscaping, located on Lot No. 3 of Tract 3492, Assessor parcel No. 513 -0- 060 -035. Industrial Planned Development- ftrmit_No. 98 -3 A two story 16,700 square foot (13,700 square foot first floor) , 3,000 square foot second floor) manufacturing warehouse building with parking and landscaping located on Lot No. 1 of Tract 3492, Assessor Parcel No. 513 -0 -060 -275. WHEREAS, at a duly noticed public hearing on June 22, 1998, the Planning Commission opened the public hearing, took testimony from all those wishing to testify, and closed the public hearing; and WHEREAS, the Planning Commission makes the following findings: CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) FINDINGS; 1. That any potential adverse impacts have been mitigated to an insignificant level. 2. The Mitigated Negative Declaration /Ini.tial Study for the project is complete and has been prepared in compliance with CEQA, and City policy. 3. The contents in the Mitigated Negative Declaration /Initial Study have been considered in the various decisions on the proposed entitlement request. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 2 4. In order to reduce the potential for adverse impacts, mitigation measures discussed in the Initial Study have been imposed as conditions of project approval. INDUSTRIAL PLANNED DEVELOPMENT FINDINGS: Based upon the information set forth above, it is determined that this application with the attached conditions, meets the requirements of the City of Moorpark Municipal Code Section 17.44.030 in ghat: 1. The proposed use is consistent with the intent and provisions of the City's General Plan and Title 17 of the Municipal Code. 2. The proposed use is compatible with the character of the surrounding development. 3. The proposed use will not be obnoxious or harmful or impair the utility of the neighboring properties or uses. 4. The-proposed use will not be detrimental to the public interest, health, safety, convenience, or welfare. 5. The proposed use is compatible with the scale, visual character and design of the surrounding properties, designed so as to enhance the physical and visual quality of the community, and the structure has design features which provide visual relief and separation between land uses of conflicting character. WHEREAS, the Planning Commission after review and consideration of the information contained in the staff report, the Mitigated Negative Declaration and public testimony, has reached a decision on this matter. NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF MOORPARE, CALIFORNIA, DOES RESOLVE AS FOLLOWS: SECTION 1. The Planning Commission does hereby find that the aforementioned projects are consistent with the City's General Plan. SECTION 2. Pursuant to the provisions of the California Environmental Quality Act (Division 13) of the Public Resources Code of the State of California {beginning at Section 21000), the Planning Commission recommends: 1. That the City Council determine that the Mitigated Negative Declaration prepared for these projects has been completed in compliance with CEQA and State Guidelines, and 2. The City •Council adopt the Mitigated Negative Declaration. The Planning Commission has received and considered the information contained in the Mitigated Negative Declaration prior to acting on the proposed project and has found that this document adequately addresses the environmental effects of the proposed project as follows: SECTION 3. That the Planning Commission recommends to the City Council approval of Industrial Planned Development Permit Nos. 98 -1, 2 and 3 subject to the following conditions: Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Page 3 CONDITIONB_OF_ APPROVAL ...FOR_INDDSTRIAL - PLANNED_. DEVBLOPIMNT_PERMIT. -NQ.. 98 -1, 98 -2 and 98 -3 Ganaral_RIquirsments Permitted Uses 1. The permit is granted for the land and project as identified on the entitlement application form and as shown on the approved plot plans and elevations. The location of all site improvements shall be as shown on the approved plot plans and elevations except or unless otherwise indicated herein in the following conditions. All proposed uses of these buildings shall be required to receive a zoning clearance from the Department of Community Development. The Department may determine that certain uses will require other types of entitlements or environmental assessment. Other. Regulations 2. The development is, subject to all applicable regulations of the M -1 Zone, and all requirements and enactments of Federal, state, Ventura County, the City authorities and any other governmental entities, and all such requirements and enactments shall, by reference, become conditions of this permit. 3. The, Industrial Planned Development Permit shall expire when any of the uses for which it is granted is abandoned for a period of 180 or more consecutive days. Submittal _of_ Plans to_Repartment of Community_Developmen[. 4. All final construction working drawings, grading and drainage plans, plot plans, final parcel map (if requested by the Director of Community Development), sign programs, and landscaping and irrigation plans (three full sets) shall be submitted to the Director of Community Development for review and approval. Use Inauguration 5. That unless the project is inaugurated (building foundation slab in place and substantial work in progress) not later than two (2) years after this permit is granted, this permit shall automatically expire on that date. The Director of Community Development may, at his or her discretion, grant up to one (1) additional one (1) year extension for project inauguration if there have been no changes in the adjacent areas and if applicant can document that he has diligently worked towards inauguration of the project during the initial two year period. The request for extension of this entitlement must be made in writing, at least thirty (30) -days prior to the expiration date of the permit. Planning Commission Resolution IPD 96 -1, 2, and 3 (Felsenthal /J &L) Paqe 4 ;.•M, MIX aw-3 MM 6. Upon expiration of this permit, or failure to inaugurate the use, the premises shall be restored by the permittee to the conditions existing prior to the issuance of the permit, as nearly as practicable. 7. No conditions of this entitlement shall be interpreted as permitting or requiring any violation of law or any unlawful rules or regulations or orders of an authorized governmental agency. In instances where more than one set of rules apply, the stricter ones shall take precedence. 8. If any of the conditions or limitations of this permit are held to be invalid, that holding shall not invalidate the remaining conditions or limitations set forth. Permittee Defense Costs 9. The permittee agrees as a condition of issuance and use of this permit to defend, at his or her sole expense, any action brought against the City because of issuance (or renewal) of this permit. Permittee will reimburse the City for any court costs and /or attorney's fees which the City may be required by the court to pay as a result of any such action or in the alternative to relinquish this permit. The City may, at its sole discretion, participate in the defense of any such action, but such participation shall not relieve permittee of his or her obligation under this condition. 0. IN .. 10. Prior to approval of construction plans for plan check or initiation of any construction activity, a Zoning Clearance shall be obtained from the Department of Community Development. If a applicant desires, construction plans may be submitted to the Building and Safety Department prior to approval of this Development Permit with a City approved Hold Harmless Agreement. 11. Prior to initial occupancy or any subsequent change of tenant occupancy, the owner of the subject building, or the owners representative shall apply for a Zoning Clearance from the Community Development Department. The purpose of the Zoning Clearance shal:L be to determine if the proposed use(s) are compatible with the zoning and terms and conditions of the permit. Oert;firatA _af__Occupancy__.Re T ui eme t 12. No use for which this permit is granted shall be commenced until a Certificate of Occupancy has been issued by the Building and Safety Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 5 Division. In addition, no Certificate of Occupancy may be issued until all on -site improvements specified in this permit have been completed or the-applicant has provided a faithful performance bond. At the discretion of the Director of Community Development, said on -site improvements shall be completed within 120 days of issuance of the Certificate of Occupancy. In case of failure to comply with any term or provision of this agreement, the city council may by resolution declare the surety forfeited. Upon completion of the required improvements to the satisfaction of the Director of Community Development, the surety may be exonerated by action of the City. 13. Prior to the occupancy, applicable proposed uses shall be reviewed and approved by the Ventura County Environmental Health Division to ensure that the proposal will comply with all applicable State and local regulations related to storage, handling, and disposal of potentially hazardous materials, and that any required permits have been obtained. If required by the County Environmental Hea:Lth Division, the applicant shall prepare a hazardous waste minimization plan. Change.. of..9wnexship - Notice 14. No later than ten (10) days after any change of property ownership or change of lessee(s) or operator(s) of the subject building, there shall be filed with the Director of Community Development the name(s) and address(es) of the new owner(s), lessee(s) or operator(s) together with a letter from any such person(s) acknowledging and agreeing with all conditions of this permit. 15. If in the future, any use or uses are contemplated on the site differing from that specified in the Zoning clearance approved for the occupancy, either the permittee, owner, or each :prospective tenant shall file a project description prior to the initiation of the use. A review by the Director of Community Development will be conducted to determine if the proposed use is compatible with the M -1 Zone and the terms and conditions of this permit and if a minor or major modification to the Planned Development is required. All applicable fees and procedures shall apply for said review. Business Registration 16. Prior to the issuance of a Zoning Clearance for tenant occupancy, the prospective tenant shall obtain a Business Registration Permit from the City. Acceptance..of...Conditions 17. The' permittee's acceptance of this permit and /or commencement of construction and/ or operations under this permit shall be deemed to be acceptance of all conditions of this permit. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Pane 6 -.�• l- -• -u -� 18. Within two days after the City Council adoption of a resolution approving the Planned Development Permit, the applicant shall submit to the City of Moorpark a check .for $1,250 plus a $ 25.00 filing fee payable to the County of Ventura, to comply with Assembly Bill 3158, for the management and protection of statewide fish and wildlife trust resources. Pursuant to Public Resources Code section 21089 (b) and Fish and Game Code section 711.4 (c), the project is not operative, vested or final until the filing fees are paid. Provision for Image Conversion of Plans into Optical Format 19. Prior to issuance of a Zoning Clearance for construction, the builder shall provide to the City an image conversion of building, landscape, public improvement and site plans into an optical format (TIF) acceptable to the City Clerk. On-sit_e..I mprrovements 20. No Zoning Clearance may be issued for building occupancy until all on -site improvements specified in this permit have been provided or the Director of Community Development approves the acceptance of a Performance Bond to guarantee the construction and maintenance of exterior improvements not related to grading, etc. Said on -site improvements shall be completed within 120 days of issuance of a Certificate of occupancy. In case of failure to comply with any term or provision of this condition, the City Council may by resolution declare the surety forfeited. Upon completion of the required improvements to the satisfaction of the City, the City Council may reduce the amount of the bond; however, the bond must be kept in full force and effect for one year after occupancy to guarantee that improvements not related to grading are maintained. ARCD._Review _of--Uses 21. Prior to occupancy, Ventura County APCD Air Pollution Control District (APCD) shall review all applicable uses to ensure compliance with the California Health and Safety Code (Section 65850.5 et seq.) regarding the use, storage and disposition of hazardous materials. Final Certificate of occupancies shall be withheld until compliance with these provisions from the Ventura County APCD is provided. 22. The applicant agrees not to protest the formation of an underground utility assessment district. Continued 23. The continued maintenance of the permit area and facilities shall be subject to periodic inspection by the City. The permittee shall be required to remedy any defects in ground or building maintenance, as indicated by the City within five (5) days after notification. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Pa4e 7 Repai- or._Maintenance of Trucks 24. No repair or maintenance of trucks or any other vehicle shall occur on site, except completely within a wholly enclosed building. Noxious odors 25. No noxious odors shall be generated from any use on the subject site. Uses and Activities to be Conducted Inside 26. All uses and activities shall be conducted inside the building(s) unless otherwise authorized by the Director of Community Development consistent with applicable zoning Code provisions. Graffiti Removal 27. The applicant and his successors, heirs, and assigns shall remove any graffiti within five (5) days from written notification by the City of Moorpark. All such graffiti removal shall be accomplished to the satisfaction of the Director of Community Development. P-ria —t-a -the Issuance.__of ayonina Cle_aranca_for._Conatruction 28. Prior to issuance of a Grading Permit, a complete landscape plan (3 sets), together with specifications and a maintenance program shall be prepared by a State Licensed Landscape Architect, generally in accordance with the Ventura County Guide to Landscape Plans, and shall be submitted to the Director of Community Development for review and approval prior to grading permit approval. The landscape plan shall include planting and irrigation specifications for manufactured slopes over three (3) feet in height. The purpose of the landscaping shall be to control erosion, prevent aesthetic impacts to adjacent property owners, mitigate the visual impacts of all manufactured slopes three (3) feet or more in height, and to replace mature trees lost as a result of construction. The final landscape plans shall also be in conformance with the conceptual landscape plan submitted with the application. The: applicant shall bear the cost of the landscape plan review, installation of the landscaping and irrigation system, and of final landscape inspection. The landscaping and planting plan submitted for review and approval shall be accompanied by a deposit as specified by the City of Moorpark. Additional funds may subsequently need to be deposited to cover all landscape plan check and inspection fees. The landscaping shall be approved by the Director of Community Development and in place and receive final inspection prior to recordation of the map or occupancy as determined by the Director of Community Development. All landscaped areas shall have an irrigation system. The City's landscape architect shall certify in writing that the landscape and irrigation system was installed in accordance with the approved Landscape and Irrigation Plans. The final landscape plans shall include landscaping Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Pace 8 specifications, planting details, and design specifications consistent with the following requirements: a. The permittee shall provide for additional enhanced landscaping equal to or greater than the cost of any trees to be removed. Additional trees which form a canopy shall be provided to shade parking and driveway areas to offset the value of the trees removed from the site. The landscape plan shall also incorporate extensive tree landscaping including specimen size trees as approved by the Director of Community Development along both Los Angeles Avenue, HWY 118 on -ramp and Condor Drive and as otherwise determined by the Director of Community Development. b. The landscaping along Los Angeles Avenue and Condor Drive shall be bermed as approved by the Director of Community Development. C. The landscape plan shall include the final design of all sidewalks, barrier walls, streetscape elements, urban landscaping and pedestrian paths within the project limits. d. All plant species utilized shall be drought tolerant, low water using variety. e. Landscaping at site entrances and exits and any intersection within the parking lot shall not block or screen the view of a seated driver from'another moving vehicle or pedestrian. f. Plantings in and adjacent to parking areas shall be contained within raised planters surrounded by six -inch high concrete curbs. g. Landscaping shall be designed so as to not obstruct the view of any exterior door or window from the :street. h. Landscaping (trees) shall not be placed directly under any overhead lighting which could cause a loss of light at ground level. I. Earthen berms, hedges and /or low walls shall be provided to screen views of parked vehicles from adjacent streets. j. Backflow preventers, transformers, or other exposed above ground utilities shall be shown on the landscape plan(s) and shall be screened with landscaping and /or at wall. k. A sufficiently dense tree planting plan emphasizing tall growing trees and /or shrubs shall be designed. Fifty (50) percent (or as otherwise determined by the Director of Community Development) of all trees shall be a minimum of 24 inch box size in order to provide screening in a three (3) to five (5) year time period. All other trees shall be a minimum 15 gallon in size. Recommendations regarding planting incorporated in the environmental document shall be incorporated to the degree feasible into the screening plan. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paoe 9 1. Irrigation shall be provided for all permanent landscaping, as identified in the approved landscape plan. The applicant shall be responsible for maintaining the irrigation system and all landscaping. The applicant shall replace any dead plants and make any necessary repairs to the irrigation system consistent with the landscape plan approved for the development. M. The transformer and cross connection water control devices shall be shown on the plot plan and landscaping and irrigation plan and screened from street view with masonry wall or landscaping as approved by the Director of Community Development. o. All perimeter and /or garden walls shall be constructed prior to installation of any sidewalks or concrete slabs. p. Elevations of proposed hardscape treatment (such as the building entrance, window and door treatment) shall be submitted with the final construction plans. q. Prior to Final Inspection, the areas to be landscaped, as shown on the irrigation plan, shall be landscaped and irrigation system installed. The City's landscape architect shall certify in writing that the landscape and irrigation system was installed in accordance rt with the approved Landscape and Irrigation Plans. r. The landscape plans shall provide for sufficient additional landscaping as Determined by the Community Development Director to the rear (north) elevations of the building to create an acceptable landscaped corridor complementing -he building elevations as viewed from Highway 118. 29. Prior to issuance of a Zoning Clearance for construction, the applicant shall provide an irrevocable offer of an easement to the City for the purpose of maintaiping all landscaping of the site adjacent to Los Angeles Avenue. The area referred to shall include all landscaped portions of the required setback area adjacent to the public right -of -way. The applicant shall be responsible for maintenance of the aforementioned area as well as the landscaping within the public right -of -way adjacent to the project. If the City at it's sole discretion determines the landscape maintenance is determined to be unsatisfactory in any of the aforementioned areas, the City may invoke the offer of dedication and assume responsibility at the owner's expense for any or all of the aforementioned areas. The total cost of maintenance for the areas noted above shall be borne by the applicant. The City may at its sole discretion place the aforementioned areas in a landscape maintenance assessment district. The applicant shall record a covenant to this effect. The applicant shall maintain the right to protest the amount and spread of any proposed assessment, but not the formation of, or annexation to a maintenance assessment district. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 10 FZ" Case - Processing -Coats 30. The applicant shall pay all outstanding case processing (planning and engineering) , and all City legal service fees prior to issuance of a Zoning Clearance for construction. In addition, the applicant shall be required to pay a Condition Compliance deposit pursuant to the requirements of the most recently adopted "Resolution Establishing Schedule of Land Development Preliminary Processing Fee Deposits ". Curr -ent.. and... Future_ Park-System Contribution 31. The applicant shall contribute to the City of Moorpark an amount of $.25 per square foot of gross floor area prior to the issuance of a Zoning Clearance for construction. The funds shall be used to support the City's current and future park system. Arland_ Public_ 21acea—Contribution 32. The applicant shall contribute to the City of Moorpark's Art in Public Places Fund, an amount of $10 per each 100 square foot of building area prior to the issuance of a Zoning Clearance for construction. The applicant may create a public art project on or off -site in lieu of paying the Art in Public Places fee. The art work must have a value corresponding to the fee and must receive approval from the City Council. 33. Prior to the issuance of a building permit, the applicant shall pay a fee established pursuant to Ordinance 102 in the amount of $.05 per square ft. of the building area. The funds shall be used to install, maintain and replace landscape work on public property for the purpose of mitigating the removal of the natural landscape from the property of the new development. 34. Prior to issuance of the first Zoning Clearance for construction, the permittee shall make a contribution to the Moorpark Traffic Systems Management Fund of $.15 per square foot of floor area to fund Traffic System Management programs for the total. square footage approved for the project. Callegua_s L Municipal Water_ nisLylct— Release 35. Prior to issuance of a Building Permit, the developer shall demonstrate by possession of a District Release from the Calleguas Municipal Water District that arrangements for payment of the Construction Charge applicable to the proposed project have been made. Applicant shall be required to comply with Ventura County Waterworks Rules and Regulations, including payment of all applicable fees. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 11 36. Prior to the issuance of a Building Permit, the applicant shall pay all school assessment fees levied by the Moorpark Unified School District, if applicable. Code-.Enforcement--Costs 37. The Director of Community Development may declare a development project that is not in compliance with the Conditions of Approval or for some other just cause, a "public nuisance ". The applicant shall be liable to the city for any and all costs and expenses to the city involved in thereafter abating the nuisance and in obtaining compliance with the Conditions of Approval or applicable codes. If the applicant fails to pay all city costs related to this action, the City may enact special assessment proceedings against the parcel of land upon which the nuisance existed (Municipal Code Section 1.12.080). Revisions. -tn_Plnt...Plan 38. The plot plan shall not be revised to re:Elect any requirements for right - of -way dedications, unless an appropriate modification is approved by the City. In addition, the following revisions to the site plan shall be made subject to the review and approval of the Director of Community Development prior to the issuance of a Zoning Clearance for construction: 1. The Plot plan and /or elevations of IPD 98 -1, 98 -2 and 98 -3 shall be revised so as to provide additional enhancement of the industrial buildings from the Freeway 118 on -ramp. Emphasis should be placed on architectural features including insets, pop -outs, soffit design, or similar treatments and should be incorporated with additional landscaped elements. 2. On IPD 98 -3 the loading areas shall. be located completely within the building, including the placement of overhead roll -up doors which shall be kept continuously closed except to allow vehicle ingress and egress. There shall be a second set of roll -up doors located inside the loading area to separate the loading zone from the leasable area to be used for manufacturing, warehouse, etc. Additionally, the enclosed loading area shall be separated with a wall from the main building area and shall be properly vented so as to avoid exhaust fumes from vehicles utilizing the loading area. 3. The site plan calculations shall be modified to identify the square footage of the building which is to be used exclusively as a loading area. The revisions are subject to the review and approval of the Director of Community Development. utility a0 m Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Page 12 39. A utility room with common access to house all meters shall be provided within the building. Us-e_.o.f_Asbesto_a 40. No asbestos pipe or construction materials shall be used. Utility. Line& 41. All proposed utility lines within and immediately adjacent to the project site (as determined by the Director of Community Development) shall be placed underground to the nearest off -rite utility pole. All existing utilities shall also be undergrounded to the nearest off -site utility pole with the exception of 69 KVA or larger power lines. This requirement for undergrounding includes all above - ground power poles on the project site as well as those along the frontage of the site. The developer shall indicate in writing how this condition wall be satisfied. Any above grade utility fixtures shall be placed adjacent. to landscaped areas and screened on three sides. Ext erior_Access 42. Exterior access ladders are not permitted. There shall not be any easy exterior access to the roof area, i.e. ].adders, trees, high walls, etc. Plat_. Plan_Recuireme is 43. The following shall be depicted on the plot plans and shall be subject to apptoval by the Director of Community Development: a. The transformer and cross connection water control devices shall be shown on the plot plan and landscaping and irrigation plan and screened from street view with masonry wall or landscaping. b. All fences and walls shall be shown on the plot plan and landscaping and irrigation plan. C. Bicycle racks or storage facilities shall be provided on -site. d. All required loading areas and turning radii shall be depicted on the plot plan. A 45 foot turning radius shall be provided for loading zones consistent with the AASHO WB -50 design vehicle. e. Elevations of proposed hardscape treatment (such as the building entrance, window and door treatment) shall be submitted with the final construction plans. Parapet_ -Wall Requirement_ 44. Roof design and construction shall include a minimum 18 -inch extension of the parapet wall above the highest point: of the flat roof area. Planning Commission Resolution IPD 99 -1, 2, and 3 (Felsenthal /J &L) Paqe 13 Lighting--- Plan 45. For all exterior lighting, a lighting plan shall be prepared by an electrical engineer registered in the State of California and submitted to the Department of Community Development for review and approval. The lighting plan shall achieve the following objectives: Avoid interferences with reasonable use of adjoining properties; minimize on -site and off -site glare; provide adequate on -site lighting; limit electroliers height; provide structures which are compatible with the total design of the proposed facility and minimize energy consumption. The lighting plan shall include the following: a. A photometric plan showing a point -by -point foot candle layout to extend a minimum of twenty (20) feet outside the property lines. Layout plan to be based on a ten (10) foot grid center. Down lighting and accent landscape and building lighting shall be employed throughout the project. b. Maximum overall height of fixtures shall be twenty five (25) feet, unless otherwise approved by the Director of Community Development. C. Fixtures must possess sharp cut -ofE qualities with a maximum of one foot candle illumination at or beyond property lines. d. Energy efficient lighting devices shall be provided. e. A minimum of one, and a maximum of two foot candle illumination with a 1.5 foot candle average, or as otherwise approved by the Director of Community Development. f. No light shall be emitted above the 90 degree or horizontal plane. No direct light source shall be visible from the street. g. Lighting devices in the parking lot shall be shielded and directed downward to avoid light and glare on neighboring properties. h. Lighting devices shall be high enough as to prohibit anyone on the ground from tampering with them unless tamper proof fixtures are approved by the Director of Community Development. All exterior lighting devices shall be protected by weather and breakage resistant covers. i. Lighting at all exterior doors shall be lighted with a minimum maintained two foot candles at ground level. 46. Prior to the issuance of a Building Permit, a copy of the lighting plans shall also be submitted to the Police for review. .. 47. All property line walls shall be no further than one inch from the property line. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 14 Downspouts. 48. No downspouts shall be permitted on the exterior of the building. 49. Roof mounted equipment is prohibited, except for equipment that cannot be mounted on the ground and approved to be! roof mounted by the Director of Community Development. No roof mounted equipment (vents, stacks, blowers, air conditioning equipment, etc.) may extend above any parapet wall, unless screened on all four sides by view obscuring material that is an intregal design element of the building. Prior to the issuance of a Zoning Clearance for construction, the final design and materials for the roof screen and location of any roof mounted equipment must be approved by the Director of Community Development. P..11 screening shall be tall enough to block all ground level views as well a.s those from HWY 118 and shall be maintained during the life of the permit. Construction material shall match the color and material used in the construction of the buildings. Colors, materials and building appendages, (such as mechanical equipment on the roof, etc.) of the proposed building shall be compatible with the existing building and adjacent development and non - reflective in nature. Exterior Ground Level-Equipment 50. Any outdoor ground level equipment and storage (such as loading docks, shelter docks, cooling towers, generators, etc.) shall be screened from view by a masonry wall, the design of which shall be approved by the Director of Community development or his designee. The wall shall be constructed of materials and colors consistent with the main building. Building - _Materials and Colors 51. All exterior building materials and paint colors shall be as submitted. 52. All roof mounted equipment and other noise generation sources on -site shall be attenuated to 45 decibels WBA) at the property line, or to the ambient noise level at the property line measured at the time of the occupant request. Prior to the issuance of a Zoning Clearance for initial occupancy or any subsequent occupancy, the Director of Community Development may request that a noise study be submitted for review and approval which demonstrates that all on -site noise generation sources will be mitigated to the required level. The noise study must be prepared by a licensed acoustical engineer in accordance with accepted engineering standards. Planning Commission Resolution IPD 98-1, 2, and 3 (Felsenthal /J &L) Paqe 15 Parking Striping nf_- Spaces 53. The striping for parking spaces and loading bays shall be maintained so that it remains clearly visible. P ,Irking Lo-t_Surfac�e 54. All parking areas shall be surfaced with asphalt or concrete and shall include adequate provisions for drainage, striping and appropriate wheel blocks, curbs, or posts in parking areas adjacent to landscaped areas. All parking and loading areas shall be maintained at all times to insure safe access and use by employees, public agencies and service vehicles. DiTnosal..AreaS._.on Plot Plan 55. All trash disposal and recycling areas shall be provided in a location which will not interfere with circulation, parking or access to the building, and shall be screened with a six foot high solid wall enclosure with metal gates. The final design and location of the trash enclosures shall be subject to review of the Director of Community Development prior to the issuance of a Zoning Clearance for construction. Trash areas and recycling bins shall be depicted on the final construction plans, the size of which shall be approved by the Director of Community Development and the City employee responsible for recycling/ solid waste management programs. a. Rubbish disposal areas shall include adequate, accessible and convenient areas for collecting and loading recyclable materials. The dimensions of the recycling area shall accommodate containers consistent with current methods of. collection in the area in which the project is located. b. Adequate number of bins or containers shall be provided to allow for the collection and loading of recyclable materials generated by the development. For commercial (general, office, or retail), developments, space allotment for 2 three cubic yard bins (107" x 84 or 168" x 53.5 ") , or a space allotment for one 40 cubic yard bin (288" x 120 ") and one 3 cubic yard bin (84" x 53.5). The intended use for this space is to hold two side -by -side 3 cubic yard containers (one for refuse, one for recyclables), or one 40 cubic yard bin for refuse and one 3 cubic yard for recyclables. C. The design of the refuse disposal areas shall be compatible in design with the development and the surrounding area. d. Disposal areas shall be protected from weather conditions which might render collected recyclable materials unmarketable. Planning Commission Resolution IPD 98 -1,.2, and 3 (Felsenthal /J &L) Paae 16 e. Driveways or travel aisles shall provide unobstructed access for collection vehicles and personnel, and provide the minimum vertical clearance of 30 feet, or other specified clearance required by the collection methods and vehicles utilized by the hauler. f. A sign, approved by the Director of Community Development, clearly identifying all recycling and solid waste collection and loading areas, and the materials accepted therein shall be posted adjacent to all points of access to the recycling areas. g. Refuse disposal areas shall not be! located in any area required by the Municipal Code to be constructed or maintained as unencumbered, according to fire and other applicable building and /or public safety laws. h. Recycling area (s) shall be located so they are convenient and adjacent to regular refuse collection areas. i. The design of the refuse and recycling enclosures shall be subject to the approval of the Director of. Community Development, prior to the issuance of a Zoning Clearance for construction. All rubbish disposal areas and recycling areas shall be screened with a six foot high, solid wall enclosure with metal gates. i. In cases where space for 2 three cubic yard bins is required (107" x 84 or 168" x 53.511), the opening of any bin enclosure must be at least 84 inches (the size of a three cubic yard bin) . This requirement applies to the amount of space exposed when the gate is fully opened. ii. Each refuse \recycling enclosure shall have gates and should be designed with cane bolts to secure the gates when in the open position. iii. Space allocation for rubbish and recycling enclosures shall be designed in a manner that complies with the equal access requirements of Title 24 and the American Disabilities Act. iv. The enclosure shall have a separate indirect pedestrian access way which does not require doors or gates. Franchise-Hauler 56. The franchised hauler designated to service this location will be determined prior to construction. 57. Prior to issuance of an Occupancy Permit, a Waste reduction and recycling plan shall be submitted to the City of Moorpark Department of Community Development prior to occupancy of the building. The plan shall include a designated building manager, who is responsible for initiating on -site waste materials recycling programs. This shall include the acquiring of Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 17 storage bins for the separation of recyclable materials and coordination and maintenance of a curbside pickup schedule. Waste._ Management-Education Program 58. The on -site building manager or designee will conduct a routine waste management education program on -site to alert employees to any new developments or requirements for solid waste management. This measure shall be coordinated through the City's Solid Waste Management Department. 11„41ding and.Safaty Unconditional Will- Serve_.e-tter 59. Prior to the issuance of a Building Permit, an "Unconditional Will Serve Letter" for water and sewer service will be obtained from the Ventura County Waterworks District No. 1. Water _.S.ervice..Connection 60. At the time water service connection is made for each project, cross connection control devices shall be installed for the water system in accordance with the requirements of the Ventura County Environmental Health Department, Enforaemant._of Vehia].e_Cadea 61. Prior to Occupancy, the applicant shall request the City to enforce appropriate vehicle codes on subject property as permitted by Vehicle Code Section 21107.7. CITY ..BNGINEER_.CONDITIONS PRIOR —TO _.ISSITANCE OF_A— GRADING PERMIT THE 1?OLLOWING CONDITIONS_. SNALL BE SATISFIED: General: 62. The developer shall demonstrate legal access to the parcel to the satisfaction of the City Engineer. Grading: 63. The Developer shall submit to the City of Moorpark for review and approval, a rough grading plan prepared by a Registered Civil Engineer, shall enter into an agreement with the City of Moorpark to complete public improvements and shall post sufficient surety guaranteeing the construction of all improvements. The grading plan shall be consistent with the approved conceptual grading plan as shown on the Tentative Parcel Map. 64. Concurrent with submittal of the rough grading plan an erosion control plan shall be submitted to the City for review and approval by the City Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 18 Engineer. The design shall include measures for hydroseeding on all graded areas within 30 days of completion of grading unless otherwise approved by the City Engineer. Reclaimed water shall be used for dust control during grading, if available from Waterworks District No. 1 at the time of grading permit approval. 65. This project is proposed to balance cut, and fill onsite. Unanticipated off -site import /export operations requiring up to 30 total truck loads of soils material shall require council approval prior to the commencement of hauling or staged grading operations. 66. Temporary irrigation, hydroseeding and erosion control measures shall be implemented on all temporary grading. Temporary grading is defined to be any grading partially completed and any disturbance of existing natural conditions due to construction activity. These measures will apply to temporary grading activity that remains or is anticipated to remain unfinished or undisturbed in its altered condition for a period of time greater than thirty (30) days or the: beginning of the rainy season whichever comes first. 67. All development areas and lots shall be designed so that surface drainage is directed to street frontages or natural or improved drainage courses as approved by the City Engineer. Geotechnical /Geology Review 68. The Developer shall submit to the City of Moorpark for review and approval, detailed Geotechnical Engineering Report certified by a California Registered Civil Engineer. The geotechnical engineering report shall include an investigation with regard to liquefaction, expansive soils, and seismic safety. The developer shall also provide a report which discusses the contents of the soils as to the presence or absence of any hazardous waste or other contaminants in the soils. Note: Review of- the geotechnical engineering report, by the City's Geotechnical Engineer, may be required. The Developer shall reimburse the City for all costs including the City's administrative fee for this review. 69. All recommendations included in the approved geotechnical engineering report shall be implemented during project design, grading, and construction in accordance with the approved project. The City's geotechnical consultant shall review all plans for conformance with the soils engineer's recommendations. Prior to the commencement of grading plan check, the developer's geotechnical engineer shall sign the plans confirming that the grading plans incorporate the recommendations of the approved soils report(s). Storm Water Runoff and Flood Control Planning: 70. The Developer shall submit to the City of Moorpark for review and approval, drainage plans, hydrologic and hydraulic calculations prepared by a California Registered Civil Engineer; shall enter into an agreement Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Page 19 with the City of Moorpark to complete public improvements and shall post sufficient surety guaranteeing the construction of all improvements. The plans shall depict all on -site and off -site drainage structures required by the City. The drainage plans and calculations shall. indicate the following conditions before and after development; a. Quantities of water, water flow rates, major water courses, drainage areas and patterns, diversions, collection systems, flood hazard areas, sumps, sump locations, detention facilities, and drainage courses. Hydrology shall be per the current Ventura County Standards except as follows: b. All storm drains shall carry a 10 -year frequency storm; C. All catch basins shall carry a 10 -year storm; d. All catch basins in a sump condition shall be sized such that depth of water at, intake shall equal the! depth of the approach flows; e. All culverts shall carry a 100 -yeas frequency storm; f. Drainage facilities shall be provided such that surface flows are intercepted and contained in a storm drain system prior to entering collector or secondary roadways; g. Under a 10 -year frequency storm, local, residential and private streets shall have one dry travel lane available on interior residential streets. Collector street shall have a minimum of one dry travel lane in each direction; h. Drainage to adjacent parcels shall not be increased or concentrated by this development. All drainage measures necessary to mitigate storm water flows shall be provided by the Developer; i. All drainage grates shall be designed and constructed with provisions to provide adequate bicycle safety to the satisfaction of the City Engineer; j. If the land to be occupied is in an area of special flood hazard, the Developer shall notify all potential buyers in writing of this hazard condition. The grading plan shall also show contours indicating the 50- and 100 -year flood levels. k. All flows from brow ditches, ribbon gutters and similar devices shall be deposited into the storm drain system prior to entering streets. If necessary, the storm drain system shall be extended beyond the public right -of -way through easements to eliminate surface flow between parcels. Both storm drain and easements outside the right -of -way are to be maintained by the owners unless otherwise approved by the City Council. Planning Commission Resolution y-- IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 20 1. Concrete drainage structures shall be tan colored concrete, as approved by the Director of Community Development, and to the extent possible shall incorporate natural structure and landscape to reduce their visibility. M. Drainage for the development shall be designed and installed with all necessary appurtenances to safely contain and convey storm flows to their final point of discharge, subject to review and approval of the City Engineer. n. A hydraulic /hydrology study shall be prepared which analyzes the hydraulic capacity of the drainage system, with and without the storm drain system for the proposed development. The Developer shall make any downstream improvements, required by Ventura County Flood Control and The City of Moorpark, to support the proposed development. o. Improvements shall be constructed to detain drainage on -site when the drainage amount is between the ten year and fifty year storm event. A rainfall intensity zone K shall be utilized in the design unless an alternate design intensity is approved by the City Engineer. 71. The applicant shall demonstrate that concentrated surface drainage from the site shall not drain over the sidewalk or driveways. 72. The Developer shall demonstrate for each building pad within the development area that the following restrictions and protections can be put in place to the satisfaction of the City Engineer: a. Adequate protection from a 100 -year frequency storm; and b. Feasible access during a 50 -year frequency storm. C. Hydrology calculations shall be per current Ventura County Standards. 73. All structures proposed within the 100 -year flood zone shall be elevated at least one foot above the 100 -year flood level. 74. The developer shall provide for all necessary on -site and off -site storm drain facilities required by the City to accommodate upstream and on -site flows. Facilities, as shown on existing drainage studies and approved by the City, shall be delineated on the final drainage plans. Either on -site retention basins or storm water acceptance deeds from off -site property owners must be specified. These facilities (if applicable) must also be acceptable to the Ventura County Flood Control District. National Pollutant—Diacharg&i Elimination..System__(NPDES) 75. The project shall include storm water measures for the operation and maintenance of the project for review and approval of the City Engineer Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Page 21 and Director of Community Development. The plans shall identify Best Management Practices (BMPs) appropriate to the uses conducted on -site to effectively prohibit the entry of pollutants into storm water runoff. a. The project plan measures shall. also include erosion control measures to prevent soil, dirt and debris from entering the storm drain system. b. The applicant is responsible for ensuring that all contractors are aware of storm water quality measures and implement such measures. Failure to comply with the approved construction BMPs will result in issuance of correction notices, citations or a stop work order. 76. All washing and or steam cleaning of equipment must be done at an appropriately equipped facility which drains into the sanitary sewer. The area must be covered and designed to prevent run -on and run -off from the area. A sign shall be posted indicating the designated washing area. Any outdoor washing or pressure washing must be managed in such a way that there is no discharge of soaps or other pollutants to the storm drain. Washwaters shall discharge to the sanitary sewer. All sanitary connections are subject to the review, approval and conditions of the wastewater plant receiving the discharge. 77. All loading dock areas must be designed to comply with DS -3 standards (BMPs). Accumulated waste water that may contribute to the pollution of storm water must be drained to the sanitary sewer, or diverted and collected for ultimate discharge to the sanitary sewer, or intercepted and pretreated prior to discharge to the storm drain system. BMPs shall be implemented to prevent potential storm water pollution. 78. Drains in any wash or process shall not discharge to the storm drain system. Drains shall connect to the sanitary sewer. Sanitary connections are subject to the review, approval and conditions of the wastewater treatment plant accepting the discharge. 79. Any storage areas approved by the City shall be designed to eliminate the potential for runoff to contact pollutants. 80. All landscaping shall be designed with efficient irrigation practices to reduce runoff, promote surface filtration, and minimize the use of fertilizers and pesticides which can contribute to runoff pollution. 81. Sidewalks and parking lots shall be swept regularly to prevent the accumulation of litter and debris. If pressure washed, debris shall be trapped and collected to prevent entry to the storm water system. No cleaning agent shall be discharged to the storm drain. If any cleaning agent or degreaser is used, washwater shall not discharge to the storm drains; washwaters shall be collected and discharged to the sanitary sewer. Discharges to the sanitary sewer are subject to the review, approval, and conditions of the wastewater treatment plant receiving the discharge. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paae 22 82. A structural control, such as an oil /water separator, sand filter, or approved equal, shall be installed on -site to intercept and pretreat storm water prior to discharging to the storm drain system. The design, location, and a maintenance schedule shall be submitted to the City Engineer and the Department of Community Development for review and approval prior to the issuance of a building permit. 83. All on -site storm drain inlets shall be labeled "NO Dumping" using appropriate methods. 84. All on -site storm drains shall be cleaned. at least; once immediately prior to the rainy season (October 15) and once in January. Additional cleaning shall be as required by the City. 85. Prior to the issuance of any construction /grading permit and /or the commencement of any clearing, grading or excavation, the applicant /owner shall submit a Stormwater Pollution Control Plan (SWPCP), on the form provided by the City for the review and approval of the City Engineer. a. The SWPCP shall be developed and implemented in accordance with requirements of the Ventura Countywide Stormwater Quality Management Program, NPDES Permit No. CAS063339. b. The SWPCP shall identify potential pollutant sources that may affect the quality of discharges to stormurater and shall include the design and placement of recommended. Best Management Practices (BMPs) to effectively prohibit the entry of pollutants from the construction site into the storm drain system during construction. C. Improvement plans shall note that the contractor shall comply to the "Cal i Forma. Storm -Water Best.. Management Practice- Handbooks- d. Prior to the issuance of any construction /grading permit and /or the commencement of any clearing, grading or excavation, the applicant /owner shall also submit a Notice of Intent (NOI) to the California State Water Resources Control Board, Storm Water Permit Unit in accordance with the NPDES Construction General Permit (No. CASQ00002) ! Waste Discharge Requirements for Discharges of Storm Water Runoff Associated with Construction Activities) . The applicant /owner shall comply with. all additional requirements of this General Permit including preparation of a Stormwater Pollution Prevention Plan ( SWPPP) e. The Subdivider /Developer shall obtain a permit from the State Water Resources Control Board for "All storm water discharges associated with a construction activity where clearing, grading, and excavation results in land disturbances of five or more acres." The developer shall submit a Notice of Intent (NOI) to the City Engineers office as proof of permit application. f. The Subdivider /Developer shall also comply with NPDES objectives as outlined in, the " Stormwater Pollution Control Guidelines for Construction Sites". This handout is available at the City Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Page 23 Engineer's office and a copy will be attached to the approved grading permit. 86. Development shall be undertaken in accordance with conditions and requirements of the Ventura Countywide Stormwater Quality Management Program, NPDES Permit No. CAS063339. 87. The project construction plans shall incorporate Best Management Practices (BMPS) applicable to the development for the review and approval of the City Engineer. Street Improvement Requirements: 88. The Developer shall submit to the City of Moorpark for review and approval, street• improvement plans prepared by a Registered Civil Engineer; and shall post sufficient surety guaranteeing the construction of the improvements. 89. The street improvements shall include concrete curb and gutter, parkways, street lights, and signing, to the satisfaction of the City Engineer. All driveway locations shall be approved by the City Engineer and the Director of Community Development. Los Angeles Avenue a. The existing eight (8) foot wide sidewalk shall remain in place. The plans shall provide for removal and replacement of all damaged sections of sidewalk and curb and gutter as directed by the City Engineer. Condor Drive b. Driveways shall be designed in accordance with the latest Ventura County Road Standards. C. The Developer shall prepare a reciprocal driveway and access easement for Lot One, Lot Two and Lot Three to cover the area shown as the "community drive" on the approved tentative plans. This document is- to be submitted to the City Engineer for review and approval and recorded with the County of Ventura prior to the issuance of a certificate of occupancy for either Lot One or Lot Two. d. The plans shall provide for removal and replacement of all damaged sections of sidewalk and curb and gutter as directed by the City Engineer. 90. Above ground obstructions (utility cabinets, mailboxes, etc.) are to placed within the right -of -way landscaping areas when ever possible. When above ground obstructions are to be placed within the sidewalk, a minimum five (5) foot clear sidewalk width must be provided around the obstruction. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 24 91. Street lights shall be provided on the improvement plans per Ventura County Standards and as approved by the City Engineer. The Developer shall pay all energy costs associated with public street lighting for a period of one year from the acceptance of the street improvements. 92. Additional surety shall be provided for resurfacing and /or repair of the full width portion of Condor Drive and Las Angeles Avenue located adjacent to the project. The surety shall be used to secure the curb replacement and, overlay or slurry of the street:, as a result of damage from construction work or utility trenching. The City may require any or all of the repairs before occupancy of the building. The surety will be returned upon the City Engineer accepting the condition of the street. Other: 93. The developer shall indicate in writing to the City the disposition of any wells that may exist within the project. If any wells are proposed to be abandoned, or if they are abandoned and have not been properly sealed, they must be destroyed or abandoned per Ventura County Ordinance No. 2372 or Ordinance No. 3991 and per Division of Oil and Gas requirements. Permits for any well reuse (if applicable.) shall conform with Reuse Permit procedures administered by the Country Water Resources Development Department. 94. All existing and proposed utilities shall be underground as approved by the City Engineer. The two power poles along the Los Angeles Avenue frontage shall be removed prior to issuance of a Certificate of Occupancy. 95. The final design and location of all barrier walls, streetscape elements, urban landscaping are subject to the approval of the Director of Community Development. 96. In accordance with Business and Professions Code 8771 the street improvement plans shall, provide for a surveyors statement on the plans, certifying that all recorded monuments in the construction area have been located and tied out or will be protected in place during construction. 97. Any right -of -way acquisition necessary to complete the required improvements will be acquired by the Developer at his expense. If any of the improvements which the applicant is required to construct or install is to be constructed or installed upon land in which the applicant does not have title or interest sufficient for such purposes, the applicant shall do all of the following at least 60 days prior to the filling of the final or parcel map for approval pursuant to Governmental Code Section 66457. a. Notify the City of Moorpark (hereinafter "City ") in writing that the applicant wishes the City to acquire an interest in the land which is sufficient for the purposes as provided in Governmental Code Section 66462.5. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /S &L) Pace 25 b. Supply the City with (I) a legal description of the interest to be acquired, (ii) a map or diagram of the interest to be acquired sufficient to satisfy the requirements of subdivision (e) of Section 1250.310 of the Code of Civil procedure, (iii) a current appraisal report prepared by an appraiser approved by the City which expresses an opinion as to the fair market value of the interest to be acquired, and (iv) a current Litigation Guarantee Report. C. Enter into an agreement with the City, guaranteed by such cash deposits or other security as the City may require, pursuant to which the applicant will pay all of the City's cost (including, without limitation, attorney's fees and overhead expenses) of acquiring such an interest in the land. 98. The Developer shall submit wall and landscaping plans showing that provisions have been taken to provide for and maintain proper sight distances. All fences, walls and other structures over six (6) feet high are to be submitted to and approved by the Director of Community Development. 99. The Developer shall post sufficient surety guaranteeing completion of all site improvements within the development and other offsite improvements required by the conditions as described herein (i.e., grading, street improvements, storm drain improvements, landscaping, fencing, bridges, etc.) or which require removal (i.e., accessways, temporary debris basins, etc.) in a form acceptable to the City. 100. The developer shall execute a covenant running with the land (or pay a traffic mitigation fee) on the behalf of itself and its successors, heirs, and assigns agreeing to participate in the formation of an assessment district or other financing technique including, but not limited to, the payment of traffic mitigation fees, which the City may implement or adopt, to fund public street and traffic improvements directly or indirectly affected by the development. 101. The applicant shall make a special contribution to the City representing the developers pro- rata share of the cost of improvements at the following intersection: New Los Angeles Avenue /Spring Road (Estimated Construction Cost $150,000) The actual contribution (pro -rata share) shall be based upon the additional traffic added to the intersection. The developer's traffic engineer shall provide the City Engineer an estimate of the projected traffic numbers for calculation of the pro -rata share. DURING GRADINGF_THE- FQLL.QWING CONDITIOHS._.SHALL APPLY 102. Grading may occur during the rainy season from October 15th to April 15th subject to installation of erosion control facilities. Erosion control measures shall be in place and functional between October 15th and April 15th. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 26 103. Prior to any work being conducted within the State, County, or City right of way, the Developer shall obtain all necessary encroachment permits from the appropriate Agencies. 104. During site preparation and construction, the contractor shall minimize disturbance of natural groundcover on the project site until such activity is required for grading and construction purposes. 105. During clearing, grading, earth moving or excavation operations, dust shall be controlled by regular watering. In addition the following measures shall apply: a. Water all site access roads and material. excavated or graded on or off -site to prevent excessive amounts of dust. Watering shall occur a minimum of at least two times daily, preferably in the late morning and after the completion of work for the day. Additional watering for dust control shall occur as directed by the City. The grading plan shall indicate the number of water trucks which will be available for dust control at each phase of grading. b. Cease all clearing, grading, earth moving, or excavation operations during periqds of high winds (greater than 20 mph averaged over one hour). The contractor shall maintain contact with the Air Pollution Control District (APCD) meteorologist for current information about average wind speeds. C. Water or securely cover all material transported off -site and on- site to prevent excessive amounts of dust. d. Keep all grading and construction equipment on or near the site, until these activities are completed. e. Face masks shall be used by all employees involved in grading or excavation operations during dry periods to reduce inhalation of dust which may contain the fungus which causes San Joaquin valley Fever. f. The area disturbed by clearing, grading, earth moving, or excavation operations shall be minimized to prevent excessive dust generation. g. Wash off heavy -duty construction vehicles before they leave the site. 106. After clearing, grading, earth moving, or excavation operations, and during construction activities, fugitive dust emissions should be controlled using the following procedures: a. Apply non - hazardous chemical stabilizers to all inactive portions of the construction site. When appropriate, seed exposed surfaces with a fast - growing, soil- binding plant to reduce wind erosion and its contribution to local particulate levels. _ Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Page 27 b. Periodically, or as directed by the City Engineer, sweep public streets in the vicinity of the site to remove silt (i.e., fine earth material transported from the site by wind, vehicular activities, water runoff, etc.) which may have accumulated from construction activities. 107. All diesel engines used in construction equipments shall use reformulated diesel fuel. 108. During smog season (May - October) the City shall order that construction cease during Stage III alerts to minimize the number of vehicles and equipment operating, lower ozone levels and protect equipment operators from excessive smog levels. The City, at its discretion, may also limit construction during Stage II alerts. 109. Construction activities shall be limited to between the following hours: a) 7:00 a.m. and 7:00 p.m. Monday through. Friday, and b) 9:00 a.m. to 6:00 p.m. Saturday. Construction work on Saturdays will require payment of a premium for City inspection services, and may be further restricted or prohibited should the City receive complaints from adjacent property owners. No construction work is to be done on Sundays, pursuant to Section 15.26.010 of the Municipal Code. 110. Truck noise from hauling operations shall be minimized through establishing hauling routes which avoid residential areas and requiring that "Jake Brakes" not be used along the haul route within the City. The hauling plan must be identified as part of the grading plan and shall be approved by the City Engineer. 111. The developer shall ensure that construction equipment is fitted with modern sound- reduction equipment. 112. Equipment not in use for more than ten minutes shall be turned off. 113. If any hazardous waste is encountered during the construction of this project, all work shall be immediately stopped and the Ventura County Environmental Health Department, the Fire Department, the Sheriff's Department, and the City Construction Observer shall be notified immediately. Work shall not proceed until clearance has been issued by all,of these agencies. 114. When in the opinion of the Building Inspection Department an attractive nuisance exists, the developer shall utilize all prudent and reasonable measures (including installation of a 6 -foot high chain link fence around the subject nuisance area(s) or provision of a full time licensed security guard) to prevent unauthorized persons from entering the area($) at any time and to protect the public from accidents and injury. 115. Equipment engines shall be maintained in good condition and in proper tune as set forth in manufacturers specifications. 116. Backfill of any pipe or conduit shall be in 4�1 fully compacted layers unless otherwise specified by the City Engineer. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Pace 28 117. Soil testing for trench compaction is to be performed on all trenches for pipe or conduit placement. The interval of testing shall be less than once every 4 feet of lift and 100 lineal. feet of trench excavated. 118. Observe a 15 mile per hour speed limit for the construction area. 119. During site preparation and construction, construct temporary storm water diversion structures per City of Moorpark standards. 120. Truck noise from hauling operations; shall be minimized through establishing hauling routes which avoid residential areas. The hauling plan must be identified as part of the grading plan and approved by the City Council. Ldje) Pei 40 is 'Lei 121. Prior to issuance of a building permit, the developer shall pay to the City the Los Angeles Avenue Area of Contribution (AOC) Fee, which shall be the dollar amount in effect at the time the fee is paid. If previous payment of this contribution can be demonstrated, to the City's satisfaction upon concurrence of the City Manager, the developer would not have to pay the AOC fee. 122. Prior to issuance of a building permit, all habitable structures shall be designed to current UBC requirements or the City approved geotechnical report requirements for the project, whichever standard is most restrictive. PRIOR_T4_LSS_UANCE_. OF_A_. CERTIFICATE OF.. QC.CUPANCYSBB__FOLLOKINGG CONDITIONS SHALL B& SATISFIED: 123. Construction of the Los Angeles Avenue and Condor Drive street /parkway improvements shall be completed to the satisfaction of the City Of Moorpark. 124. If damaged and directed by the City Engineer or Public Works Director, the developer shall have repaired, overlayed or slurried that portion of Condor Drive adjacent the development. The repairs, overlay or slurry repairs shall extend from curb to curb along the entire length of the project including transitions unless otherwise approved and shall be completed to the satisfaction of the City Engineer. PRIOR TO- OF_ PUBLIC IMPROiEMEXUIL Affil BOND - XCHERATT -OX THE FOLLOWING CONDITIONS _.SNALL_.BE_SATISFIED: 125. Sufficient surety in a form acceptable to the City guaranteeing the public improvements shall be provided. 126. All, surety guaranteeing the public improvements shall remain in place for one year following acceptance by the City. Any surety bonds that are in effect three years after final map approval or issuance of the first Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 29 building permit shall be increased an amount equal to or greater than the consumers price index (Los Angeles /Long Beach SMSA) for a period since original issuance of the surety and shall be increased in like manner each year thereafter. 127. Original "as built" plans will be certified by the Developer's civil engineer and submitted with two sets of blue prints to the City Engineer's office. Although grading plans may have been submitted for checking and construction on sheets larger than 22" X 3611, they must be resubmitted as "record drawings" in a series of 22" X 36" mylars (made with proper overlaps) with a title block on each sheet. Submission of "as builts" plans is required before a final inspection will be scheduled. FIBS DEPARTKENT..00NDIT24NS 128. Prior to construction the applicant shall submit two (2) site plans to the Fire District for the review and approval of the location of fire lanes. The fire lanes shall be posted in accordance with California Vehicle Code, Section 22500.1 and Article 10 of the Uniform Fire Code prior to occupancy. 129. Prior to combustible construction, all weather access road /driveway suitable for use by a 20 ton Fire District vehicle shall be installed. 130. The access roadway(s) shall be extended to within 150 feet of all portions of the exterior walls of the first floor of any building. Where the access roadway cannot be provided, approved fire protection systems or systems shall be installed as required and acceptable to the Fire District. 131. Any structure greater than 5,000 square feet and /or five miles from a fire station shall be provided with an automatic fire sprinkler system in accordance with Ventura County Ordinance! No. 22. 132. Building Plans for all A,E,H and I occupancies shall be submitted to the Fire District for plan check. 133. All driveways shall have a minimum vertical clearance of 13 feet 6 inches (13' 6 ") . 134. Address numbers, a minimum of 6 inches (611) high, shall be installed prior to occupancy, shall be of contrasting color to the background, and shall be readily visible at night. Where structures are set back more than 250 feet (2501) from the street, larger numbers will be required so that they are distinguishable from the street. In the event the structure(s) is not visible from the street, the address number(s) shall be posted adjacent to the driveway entrance. A plan shall be submitted to the Fire District for review indicating the method in which buildings are to be identified by address numbers. 135. Prior to construction, the applicant shall submit plans to the Fire District for approval of the location of hydrants. On plans, show existing hydrants.within 300 feet of the! development. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paoe 30 136. Fire hydrants shall be installed and in service prior to combustible construction and shall conform to the minimum standard of the MOORPARK Water Works Manual. a. Each hydrant shall be a 6 inch wet barrel design and shall have (1) 4 inch and (2) 2 � inch outlet(s). b. The required fire flow shall be achieved at no less than 20 psi residual pressure. C. Fire hydrants shall be spaced 300 feet on center and so located that no structure will be farther than 150 feet from any one hydrant. d. Fire hydrants shall be set back in from the curb face 24 inches on center. 137. The minimum fire flow required shall be determined by the type of building construction, proximity to other structures, fire walls, and fire protection devices provided, as specified by the 1994 Uniform Fire Code Appendix III -A and adopted Amendments. Given the present plans and information, the required fire flow is approximately 2250 gallons per minute at 20 psi. The applicant shall verify that the water purveyor can provide the required volume at the project. 138. Building shall be protected by an automatic sprinkler system, plans shall be .submitted, with fees for plan review and approval, to the Fire District. 139. Building plans of all Assembly and Hazardous occupancies shall be submitted with fees for plan review and approval, to the Fire District. 140. Plans for any fire alarm system shall be submitted with fees for plan review and approval to the Fire District.. 141. Fire extinguishers shall be installed in accordance with National Fire Protection Association Pamphlet #10. The, placement of extinguishers shall be subject to review and approval by the! Fire District. 142. All grass or brush exposing any structure(s) to fire hazards shall be cleared for a distance of 100 feet prior to framing, according to the Ventura County Fire Protection Ordinance:. 143. Commercial trash dumpsters and containers with an individual capacity of 1.5 cubic yards or greater shall not be stored or placed within 5 feet of openings, combustible walls, or combustible roof eave lines unless protected by approved automatic fire sprinklers. (Uniform Fire Code, Article 11.) 144. Portions of this development may be in a high fire hazard area and those structures shall meet hazardous fire area building code requirements. 145. Applicant shall obtain and comply with the provisions of VCFD Form #126 "Requirements For Construction" prior to obtaining a building permit for any new structures or additions to existing structures. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 31 Construction Site. Security Proviaiona. All new construction, shall comply with the following security measures until the utilities have been released by the City: 146. Perimeter lighting shall be installed at. a minimum of 150 foot intervals and at a height not less than 15 feet from the ground. The light source used shall have a minimum light output of 2000 lumens, be protected by a vandalism resistant cover, and be lighted during the hours of darkness. Additional lighting shall be required if the construction site exceeds four acres in area. Lighting shall be installed at locations designated by the Chief of Police. 147. In addition to perimeter lighting described in Subsection A of this section, one of the following shall be used: a. Fencing, not less than six feet in height, which is designed to preclude human intrusion, shall be installed along the perimeter boundaries of the construction site; or b. A uniformed security guard, licensed according to Business and Professions Code, Chapter 11, shall be utilized to continually patrol the construction site during the hours when construction work has ceased. C. Construction equipment, tools and materials will be properly secured to prevent theft during non - working hours. d. All computers and appliances (microwave ovens, dishwashers, trash compactors, etc.) Will be properly secured to prevent theft prior to installation during non - working hours. All serial numbers will be recorded for identification purposes. e. If an alarm system is used, it should be wired to all exterior doors, windows, roof vents or other roof openings where access may be made. 148. Security Guard. After occupancy the applicant shall provide a security guard on -site, if required by the Police; Department. 149. Ext_erior_Eccasa, There shall not be any easy exterior access to the roof area, i.e. ladders, trees, high walls, etc. 150. W;Lndows_. and _Sliding Glass_poora. The following requirements must be met for windows and sliding glass doors: A. Except as otherwise provided by this chapter, all operable exterior windows and sliding glass doors shall comply with the tests set forth in this chapter. B. Louvered windows shall not be used, when a portion of the window is less than 12 feet vertically or 6 feet horizontally from an Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paae 32 accessible surface or any adjoining roof, balcony, landing, stair tread, platform, or similar structure. 151. Qarage -.type Donxz . All garage doors shall conform to the following standards: A. Wood doors shall have panels a minimum of 5/16 inch in thickness with the locking hardware being attached to the support framing. B. Aluminum doors shall be a minimum thickness of .0215 inches and riveted together a minimum of eighteen (18) inches on center along the outside seams. There shall be a full width horizontal beam attached to the main door structure which shall meet the pilot, or pedestrian access, door framing within three (3) inches of the strike area of the pilot or pedestrian access door. C. Fiberglass doors shall have panels, a minimum density of six ounces per square foot from the bottom of the door to a height of seven (7) feet. Panels above seven (7) feet and panels in residential structures shall have a density not less that five (5) ounces per square foot. D. Doors utilizing a cylinder lock shall have a minimum five -pin tumbler operation with the locking bar or bolt extending into the receiving guide a minimum of one (.1) inch. E. Doors that exceed 16 feet in width, but do not exceed 19 feet in width, shall have the following options as to locking devices: 1. Two lock - receiving points, or one garage- door -type slide bolt may be used if mounted no higher that 26 inches from the bottom of the door; 2. A single bolt may be used if placed in the center of the door with the locking point located either at the floor or door frame header; 3. Torsion spring counter balance type hardware may be used if such hardware substantially complies with the requirements of this chapter. F. Except in a residential building, doors secured by electrical operation shall have a keyed switch to open the door when in a closed position, or shall have a :signal locking device to open the door. G. Doors with slide bolt assemblies shall have frames of a minimum of .120 inches in thickness, with a minimum bolt diameter of one -half inch and protrude at least 1 % inches into the receiving guide. A bolt diameter of 3/8 inch may be used in a residential building. The slide bolt shall be attached to the door with non - removable bolts from the outside. Rivets shall not be used to attach slide bolt assemblies. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 33 H. Except in a residential building, padlock(s) used with exterior mounted slide bolt(s) shall have a hardened steel shackle locking both at heed and toe and a minimum five pin tumbler operation with non - removable key when in an unlocked position. Padlock(s) used with interior mounted slide bolts(s) shall have a hardened steel shackle with a minimum four -pin tumbler operation. 152. Landscaping shall not cover any exterior door or window. Landscaping shall not reduce the visibility of passing motorists view of activities in the parking area. 153. Landscaping at entrances /exits or at any intersection will not block or screen the view of a seated driver from another moving vehicle or pedestrian. 154. Landscaping (trees) will not be placed directly under any overhead lighting which could cause a loss of light at ground level. special BuildinT- p�.oyisiQne -- Commercial. 155. Swinging exterior glass doors, wood or metal doors with glass panels, solid wood or metal doors shall be constructed or protected as follows: A. Wood doors shall be of solid core construction with a minimum thickness of 1 3/4 inches. Wood panel doors with panels less than one inch thick shall be covered on the inside with a minimum sixteen U.S. gauge sheet steel, or its equivalent, which is to be attached with screws on minimum six: -inch centers. Hollow steel doors shall be of a minimum sixteen U.S. gauge and have sufficient reinforcement to maintain the designed thickness of the door when any locking device is installed; such reinforcement being able to restrict collapsing of the door around any locking device. B. Except when double cylinder dead bolts are utilized, any glazing in exterior doors or within 48 inches of any door - locking mechanism shall be constructed or protected as follows: 1. Fully tempered glass or rated burglary resistant glazing; or 2. Iron or steel grills of at least 1/8 inch material with a minimum two -inch mesh secured on the inside of the glazing may be utilized; or 3. The glazing shall be covered with iron bars of a least one -half inch round or one inch by 1/4 inch flat steel material, spaced not more than five inches apart, secured on the inside of the glazing; 4. Items b and c shall not interfere with the operation of opening windows if such windows are required to be openable by the Uniform Building Code. 156. All swinging exterior wood and steel doors shall be equipped as follows Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Pa4e 34 A. A single or double door shall be equipped with a double cylinder dead bolt. The bolt shall have a minimum projection of one inch and be constructed so as to repel cutting tool attack. The dead bolt shall have an embedment of at least 3/4 inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least 1/4 inch in diameter. The provisions of the preceding paragraph do not apply where: 1. Panic hardware is required; or 2. An equivalent device is approved by the enforcing authority. B. Double doors shall be equipped as follows: 1. The inactive leaf of double door (a) shall be equipped with metal flush bolts having a minimum embedment of 5/8 inch into the head and threshold of the door frame. 2. Double doors shall have an astragal constructed of steel a minimum of .125 thick which will cover the opening between the doors. The astragal shall be a minimum of two inches wide, and extend a minimum of one inch beyond the edge of the door to which it is attached. The astragal shall be attached to the outside of the active door by means of welding or with non - removable bolts spaced apart on not more that ten -inch centers. The door to which such an astragal is attached must be determined by the fire safety codes adopted by the enforcing authority. 3. Every single or double exterior door equipped with lever - handled locking mechanism hardware shall have an approved handicapped - accessible threshold complying with provisions of Title 24 of the Uniform Building Code (as amended from time to time) beneath the door. The opening between the threshold and the door shall be secured in a manner approved by the Crime Prevention Bureau of the Moorpark Police Department designed to prevent the passing of rigid materials or mechanical devices between the door and the threshold for the purposes of unlocking the door from the interior side. 157. Aluminum frame swinging doors shall be equipped as follows: A. The jamb on all aluminum frame swinging doors shall be so constructed or protected to prevent pealing of the door frame around the strike and withstand 1600 pounds of pressure in both a vertical distance of three inches and a horizontal distance of one inch each side of the strike, so as to prevent violation of the strike. B. A single or double door shall be equipped. with a double cylinder dead bolt with a bolt projection exceeding one inch, or a hook shaped or expanding dog bolt that engages the strike sufficiently to prevent spreading. The dead bolt lock shall have a minimum of five pin tumblers and a cylinder guard. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paqe 35 158. Panic hardware, whenever required by the Uniform Building Code or Title 19, California Administrative Code, shall be installed as follows: A. Panic hardware shall contain a minimum of two locking points on each door; or B. On single doors, panic hardware may have one locking point which is not to be located at either the tope or bottom rails of the door frame. The door shall have an astragal constructed of steel .125 inch think which shall be attached with non - removable bolts to the outside of the door. The astragal shall extend a minimum of six inches vertically above and below the latch of the panic hardware. The astragal shall be a minimum of two inches wide and extend a minimum of one inch beyond the edge of the door to which it is attached. C. Double doors containing panic hardware shall have an astragal attached to the doors at their meeting point which will close the opening between them, but not interfere with the operation of either door. 159. Horizontal sliding.doors shall be equipped with a metal guide track at top and bottom and a cylinder lock and /or padlock with a hardened steel shackle which locks at both heel and toe:, and a minimum five pin tumbler operation with non - removable key when in an unlocked position. The bottom _ track shall be so designed that the door cannot be lifted from the track when the door is in a locked position. 160. In office buildings (multiple occupancy) , all entrance doors to individual office suites shall meet the construction and locking requirements for exterior doors. 161. Windows shall be deemed accessible if less than twelve feet above ground. Accessible windows and all exterior transoms having a pane exceeding 96 square inches in an area with the smallest dimension exceeding six inches and not visible from a public or private vehicular access way shall be protected in the following manner: A. Fully tempered glass or burglary resistant glazing; or B. The following window barriers may be used but shall be secured with non- removable bolts: 1. Inside or outside iron bars of at least % inch round or one inch by 1/4 inch flat steel material, spaced not more than five inches apart and securely fastened; or 2. Inside or outside iron or steel grills of at least 1/8 inch material with not more than a two -inch mesh and securely fastened. C. If a side or rear window is of the type that can be opened, it shall, where applicable, be secured on the inside with either a slide bar, bolt, crossbar, auxiliary locking device, and /or padlock with hardened steel shackle, a minimum four pin tumbler operation. Planning Commission Resolution f^ IPD 98 -1, 2, and 3 (Felsenthal /J &L) Page 36 D. The protective bars or grills shall not interfere with the operation of opening windows if such windows are required to be openable by the Uniform Building Code. 162. Roof openings shall be equipped as follows: A. All skylights on the roof of any building or premises used for business purposes shall be provided with: 1. Rated burglary resistant glazing; or 2. Iron bars of at least 2A inch round or one inch by 1/4 inch flat steel material under the skylight and securely fastened; or 3.A steel grill of at least 1/8 inch material with a maximum two -inch mesh under the skylight and securely fastened. B. All hatchway openings on the roof of any building or premises used for business purposes shall be secured as follows: 1. If the hatchway is of wooden material, it shall be covered on the inside with at least sixteen U.S. gauge sheet metal, or its equivalent, attached with screws. 2. The hatchway shall be secured from the inside with slide bar or slide bolts. 3. Outside hinges on all hatchway openings shall be provided with non- removable pins when using pin -type hinges. C. All air duct or air vent openings exceeding 96 square inches on the roof or exterior walls of any building or premises used for business purposes shall be secured by covering the same with either of the following: 1. Iron bars of at least >M inch round or one inch by 1/4 inch flat steel material spaced no more than five inches apart and securely fastened; or 2. Iron or steel grills of at least 1/8 inch material with a maximum two -inch mesh and securely fastened. 3. If the barrier is on the outside, it shall be secured with bolts which are non - removable from the exterior. 4. The above (a and b) must not interfere with venting requirements creating a potentially hazardous condition to health and safety or conflict with the provisions of the Uniform Building Code or Title 19, California Administrative Code. 163. Permanently affixed ladders leading to roofs shall be fully enclosed with sheet metal to a height of ten feet. This covering shall be locked against the ladder with a case - hardened hasp, secured with non - removable screws or bolts. Hinges on the cover will be provided with non - removable pins when Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Page 37 using pin -type hinges. If a padlock is used, it shall have a hardened steel shackle, locking at both heel and toe, and a minimum five -pin tumbler operation with non - removable key when in an unlocked position. 164. The following standards shall apply to lighting, address identification and parking areas: A. The address number of every commercial building shall be illuminated during the hours of darkness so that it shall be easily visible from the street. The numerals in these numbers shall be no less than six inches in height and be of a color contrasting to the background. In addition, any business which affords vehicular access to the rear through any driveway, alleyway or parking lot shall also display the same numbers on the rear of the building. B. All exterior commercial doors, during the hours of darkness, shall be illuminated with a minimum of two foot candles of light. All exterior bulbs shall be protected by weather and vandalism resistant covers. C. Open parking lots, and access thereto, providing more than ten parking spaces and for use by the general public, shall be provided with a maintained minimum of one foot candle: of light on the parking surface from dusk until the termination of business every operating day. 165. Mechanical Parking Gates - Emergency Override Control Devices Required. Except as otherwise provided in this section, owners or operators of controlled vehicle parking areas and private streets which use mechanical parking gates to control motor vehicle ingress or egress shall install and maintain an emergency override control device on each gate. Said device shall be a master key- operated type switch which shall comply with City of Moorpark Police Department standards. Provisions of this Section shall not apply to a vehicle parking area or private street when emergency or other pubic service vehicles have immediate access to said parking area or private street without delay. Except as otherwise provided in this section, emergency override control devices shall be required for all said mechanical parking gates whether or not said gates were installed before or after the effective date of this ordinance. Additional_Security __Re ¢ uirements. 166. Exterior Trash Enclosures. The Exterior Trash Enclosures shall include locking hardware which allows for the :Locking of the enclosures during both business and non - business hours. Unlocked trash enclosures provide an attractive hiding place for the storage of merchandise during employee theft, particularly those enclosures near employee parking stalls. Unlocked trash enclosures provide attractive targets for unwelcome individuals who search through trash dumpsters for salvage items. Additionally, any key or combination to a lock should be given to the company providing trash service. Planning Commission Resolution IPD 98 -1, 2, and 3 (Felsenthal /J &L) Paae 38 167. East Elevation. The east side of the building shall be illuminated during the hours of darkness to illuminate anyone who may be loitering near the building. This may also discourage graffiti vandals and at least allow for discovery of vandals during the commission of the crime. Illumination shall be accomplished by a minimum of one 150 watt wall pack on the east wall of he building. Additionally, it is strongly recommended that there be landscaping along the east side of the building which discourages vandals, yet does not provide concealment for them. K&TERWORRS DISTRICT..NQ.. 1 168. Applicant for service shall comply with the District "Rules and Regulations" including all provisions of or relating to the existing Industrial Waste Discharge Requirements and subsequent additions or revisions thereto. The action of the foregoing direction was approved by the following roll call vote: AYES: Millhouse, Acosta, Miller, DiCecco, Lowenberg. NOES: PASSED, APPROVED, AND ADOPTED THIS 22ND DAY OF JUNE, 1998. ATTEST: Celia LaFleur, Secretary to the Planning Commission