Loading...
HomeMy WebLinkAboutAGENDA REPORT 2001 0207 CC REG ITEM 11Fnmm �• of d2 AC T i O.N: MOORPARK CITY COUNCIL AGENDA REPORT TO: The Honorable City Council FROM: Mary K. Lindley, Director of Community Service4n( ") DATE: January 30, 2001 (CC Meeting of February 7, 2001) SUBJECT: City Energy Conservation Measures DISCUSSION At the request of the Governor's Office, the League of California Cities requested that its member cities reduce their energy consumption by five percent. As a result, your staff reviewed the City's typical energy use and attempted to identify steps that can be taken to reduce energy consumption with relatively little impact or inconvenience to the public. Attached to this Agenda Report is a memo drafted by Ken Gilbert, Director of Public Works that gives a summary of the City's energy use for the month of November. As you can see, streetlights make up the bulk of the City's energy usage, at approximately 82,844 KWh per month. Arroyo Vista Community Park, the Recreation Center and gym, is the City's second largest usage source at approximately 13,777 KWh per month. Mr. Gilbert also indicates that the City plans to perform a LED conversion of its and Caltrans' traffic signals prior to June, 2001. Once completed, it is anticipated that the City will reduce its electrical usage by 34,800 KWh per month, which will lead to an 18 percent reduction, well in excess of the 5 percent requested by the Governor. Additionally, staff identified more actions that could be taken to help reduce the City's consumption and each staff member was asked to implement these steps effective immediately. These steps include, turning off lights when leaving an empty room, M: \MLindley\Administration \Energy Reduction ccagda.doc 0210 Energy Conservation Page 2 shutting down all computers at the end of each day, discontinuing the use of space heater and fans, changing out the fluorescent 40 watts lights to 34 watts lights, discontinuing the use of the oldest copier that often stands idle, and discontinuing the practice of keeping one light on in City Hall, the Community Center, and AVRC overnight. It is not anticipated that these steps alone will create a five percent reduction in energy use. There are other policy related steps the City Council could consider that will have greater energy reduction impacts including, but not limited to: discontinuing the rental use of softball field (AVCP and Peach Hill Park) and basketball court (Griffin Park) lights - it is recommended that the City continue to allow Moorpark Basketball Association's use of the AVCP gym for it's season; discontinue building rentals (AVRC and Community Center); reduce AVRC hours with concurrent reduction of programs; reduce hours at City Hall; discontinue lighting the Community Center flag pole and monument sign; supply City Hall energy needs via the emergency generator for a specific number of hours per week; and install motion sensors to activate certain security lights. Staff will continue to evaluate and implement other measures as determined feasible based on cost, safety and other factors. We do not propose turning off any streetlights at this time. STAFF RECOM4ENDATION Receive and file report. Attachment: Ken Gilbert Memorandum %al M E M O R A N D U M TO: Steven Kueny, City Manager FROM: Ken Gilbert, Director of Public Works DATE: January 12, 2001 SUBJECT: Electrical Energy Use Reduction Based on a quick review of one month's invoice from SCE, the following statistics are offered for your consideration: A. Costs per Month 1. $28,000+ Total - $13,700 lamp fee = $14,300: energy use 2. $18,000+ Street lights - $13,700 = $ 4,300: St. light energy 3. Only $4,300+ of the $18,000 + / Mo. for street lights is for energy -- the rest is a per lamp charge 4. Street light energy costs is $0.05+ / KWh S. The rate for all other invoices is $0.065 / KWh B. Use Per Month 1. 190,000 KWh Total [5% of Total is 9,500KWh] 2. 82,844 KWh Street Lights (43 %) 3. 8,490 KWh City Hall 4. 2,190 KWh Annex 5. 13,777 KWh Community Center 6. 1,415 KWh one typical traffic signal 7. 1,133 KWh PW Yard 8. 24,759 KWh AVCP C. LED Conversion Projects: The Traffic Signal LED conversion projects will result in a considerable reduction in electrical usage, summarized as follows: 1.Initial Project (City Signals): Before: 1400 KWh / mo. After: - 200 KWh / mo. 1200 KWh / mo. / signal savings x 15 signals 18,000 KWh / mo. savings 2. Phase 2 (Caltrans Signals): Before: 1400 KWh j mo. After: - 200 KWh j mo. 1200 KWh / mo. / signal savings x 14 signals 16,800 KWh / mo. savings 3. Total Savings: 34,800 KWh / mo. Electrical Energy Use Reduction C 3021-11:1! Electrical Energy Use Reduction January 12, 2001 Page 2 D. Other Use Reduction Efforts 1. Practices: a. Shorter work week b. Shorter time for use of facilities by the public c. Turn -off ball field lights during rain d. Turn -off flag pole light (remove flag at night) e. Turn -off civic center monument sign light f. Turn -off computers at night g. Turn -off lights when area not in use h. Turn -off copier (three in City Hall) i. Intermittent use of Emergency Generator to power City Hall 2. Capital Conversion Projects: The cost for the following capital conversion projects have not yet been determined. a. Florescent bulbs: 40W to 34W b. Install motion sensor to activate security lights instead of leaving lights on all night c. Change to solar irrigation controllers d. Upgrade Generator to power City Hall at all hours e. Add Gas service at the Yard Electrical Energy Use Reduction C 0l 21 3