Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AGENDA REPORT 2011 0720 CC REG ITEM 09C
ITEM 9.C. ni 1 v OF MOOR?ARK,CAUFORN'. City Council Meeting ACTION:_. god.,1.s .ot-& Vr MOORPARK CITY COUNCIL AGENDA REPORT'_ fir — TO: Honorable City Council FROM: Jeremy Laurentowski, Landscape and Parks Manager DATE: July 8, 2011 (CC Meeting of July 20, 2011) SUBJECT: Consider Retrofitting the Existing Lighting at the Active Adult Center, Community Center, City Hall Administration Building, Development Services Building, Civic Center Parking Lot and Library Parking Lot; Award Contract to Sylvania Lighting Services Corporation and Authorize City Manager to Execute Agreement; and Resolution Amending the Fiscal Year 2011/12 Budget BACKGROUND In 2009, the City obtained an Energy Efficiency and Conservation Block Grant (EECBG), as a part of the American Recovery and Reinvestment Act (ARRA), in the amount of $148,600 for energy efficiency upgrades to the existing facilities Heating, Ventilation and Air Conditioning (HVAC) and Lighting Systems. During the June 16, 2010 City Council meeting, staff recommended two (2) phases to expend these grant monies which would yield the highest energy savings for the least amount of investment. Phase 1 included the replacement of seven (7) HVAC units that serve the Community Center and the Active Adult Center and was completed in December, 2010. Staff anticipates approximately 25% a year in direct energy savings due to the replacement of the HVAC units. Phase 2 included retrofitting the interior and exterior lighting of several City facilities. Staff has obtained an inventory and audit of all existing lighting systems at the City facilities and has solicited a fee proposal from Sylvania Lighting Services (Sylvania) to complete this work. DISCUSSION The City Council is being asked to approve retrofitting the existing lighting systems that serve the Active Adult Center, Community Center, City Hall Administration Building, the Development Services Building, Civic Center parking lot and the Library parking lot. According to the Lighting Upgrade Proposal and analysis prepared by Sylvania, retrofitting the existing lighting with new energy efficient lighting systems would result in substantial energy savings. In addition, it will help the City comply with current Title 24 lighting standards, the new Federal Minimum Energy Standards, reduce carbon emissions and reduce annual maintenance costs. SACommunity Services\ADMINISTRATIVE\CC Reports\2011\Facilities\City Hall\7-8-11 (Lighting Retrofit).doc 64 Honorable City Council July 20, 2011 Page 2 Staff is proposing to replace the interior and exterior lighting of several City facilities with a variety of energy efficient lighting upgrades. A major part of this project will include the change from traditional fluorescent T12 bulbs to low wattage fluorescent T8 bulbs. The fluorescent bulb identification terms, T'12' and T'8', refer to the diameter of the fluorescent tube in eighths of an inch. T12's are 12/8th of an inch, or 1 Y2" diameter, and T8's are 8/8th of an inch, or 1" in diameter. T12's use 40 watts of energy per bulb, as compared to 32 watts for each T8, ultimately reducing carbon emissions as the overall energy requirement at each facility will be reduced. Carbon is a byproduct of energy production. In addition, T8's have a life span of approximately 36,000 hours, compared to 20,000 hours for T12's, reducing overall product costs, maintenance costs and the staff time required to replace bulbs. However, staff has discovered that there are substantial challenges that exist with office lighting, specifically as it relates to lighting where employees are working on a computer, as well as referencing documents. According to the Illuminating Engineering Society of North America (IESNA), working at a computer requires light levels in the range of 10 footcandles, while referencing a document can require as much as 100 footcandles. In addition to varying light levels, individuals require different light levels based on distinct visual systems and comfort levels. In October, 2010, staff enlisted the services of Humanscale, a manufacturer of ergonomic office tools designed to solve functional problems in the workplace. Humanscale provided a lighting audit of the City Hall Administration Building. Their analysis confirms that most of the individual offices are currently too bright to comfortably work at a computer monitor, but not bright enough where employees need to reference documents. The light output within individual work stations and offices averaged between 27.1 and 36.4 footcandles. In addition, the Humanscale audit confirms that the common spaces and walkways between private offices and cubicles are over-illuminated. The Occupational Safety and Health Administration (OSHA) recommends light levels in the range of 30 footcandles for general use areas. Much of the common spaces in the Administration Building were illuminated between 50 and 61 footcandles. It has also been suggested that lower light levels increase productivity, alertness, comfort and may reduce headaches due to reduced eyestrain and frowning associated with ambient glare. In an effort to provide appropriate lighting levels, staff is recommending removing the existing four (4) lamp prismatic fixtures and replacing the fixtures with two (2) lamp fixtures with reflective lenses. Staff is confident that acceptable lighting levels will be obtained as the T8's emit higher lumens per bulb and loose only 10% of their initial brightness after approximately 7,000 hours of use, compared to T12's that loose approximately 20% over the same time frame. Staff is proposing to provide overhead task lighting to staff members that require increased illumination at their workspace. Staff is also proposing to replace the existing Metal Halide and High Pressure Sodium parking lot lights and exterior building lights with Light Emitting Diode (LED) lighting. LED lighting has a lifespan of approximately 50,000 hours with an estimated energy savings between 50% and 75% compared to traditional high wattage bulbs, such as Metal Halide and High Pressure Sodium. LED lighting has a high initial cost. However, 65 Honorable City Council July 20, 2011 Page 3 substantial savings in direct energy cost savings makes this product a viable solution for energy conservation. The Community Development Department will review any exterior lighting plans for glare reduction compliance. Staff has also obtained a proposal to retrofit the interior lighting of each City facility with LED lighting. However, the high initial cost due to the quantity of the fixtures and the relatively low wattage requirement of each facility makes LED interior lighting cost prohibitive. Staff has determined that the average cost recovery for interior LED lighting is between 15 and 20 years. LED interior lighting is also a relatively new product and several lighting professionals have cautioned staff on moving forward with these products at this time. As mentioned previously, most manufacturers claim that LED lighting has a 50,000 hour lifespan. These products have not been in production long enough to substantiate 15 years of performance. A summary of each facility follows (See Attachment 2, Lighting Upgrade Proposals): Active Adult Center Annual kWh (kilowatt-hour) Reduction 11,433 kWh Annual Direct Energy Cost Reduction @ $0.15/kWh $ 1,715 Annual Lamp Maintenance Savings $ 726 Annual Air Conditioning Savings $ 529 Sub-Total Annual Savings $ 2,970 Project Investment $ 9,350 Estimated SCE Rebate $ 1,301 Net Project Investment $ 8,049 Project Payback Period (years) 2.71 Community Center Annual kWh (kilowatt-hour) Reduction 22,245 kWh Annual Direct Energy Cost Reduction @ $0.15/kWh $ 3,337 Annual Lamp Maintenance Savings $ 761 Annual Air Conditioning Savings $ 759 Sub-Total Annual Savings $ 4,857 Project Investment $ 15,245 Estimated SCE Rebate $ 2,334 Net Project Investment $ 12,911 Project Payback Period (years) 2.66 66 Honorable City Council July 20, 2011 Page 4 City Hall Administration Building and Civic Center Parking Lot Annual kWh (kilowatt-hour) Reduction 44,493 kWh Annual Direct Energy Cost Reduction @ $0.15/kWh $ 6,674 Annual Lamp Maintenance Savings $ 678 Annual Air Conditioning Savings $ 1,162 Sub-Total Annual Savings $ 8,514 Project Investment $ 41,851 Estimated SCE Rebate $ 4,538 Net Project Investment $ 37,313 Project Payback Period (years) 4.38 City Hall Development Services Building Annual kWh (kilowatt-hour) Reduction 17,304 kWh Annual Direct Energy Cost Reduction @ $0.15/kWh $ 2,596 Annual Lamp Maintenance Savings $ 532 Annual Air Conditioning Savings $ 531 Sub-Total Annual Savings $ 3,659 Project Investment $ 13,637 Estimated SCE Rebate $ 2,395 Net Project Investment $ 11,242 Project Payback Period (years) 3.07 Library Parking Lot Annual kWh (kilowatt-hour) Reduction 10,770 kWh Annual Direct Energy Cost Reduction @ $0.15/kWh $ 1,616 Annual Lamp Maintenance Savings $ 88 Annual Air Conditioning Savings $ - Sub-Total Annual Savings $ 1,704 Project Investment $ 12,445 Estimated SCE Rebate $ 700 Net Project Investment $ 11,745 Project Payback Period (years) 6.9 67 Honorable City Council July 20, 2011 Page 5 In 2010, the County of Ventura, in collaboration with the Ventura County Regional Energy Alliance (VCREA), developed a Request for Proposals (RFP), County of Ventura Request for Proposals No. 5554, for lighting services, in anticipation of the ARRA project funding. The 2010 RFP and contract (Contract No. 6293) superseded an earlier RFP and contract developed in 2004. The "heart" of the RFP is a unit pricing schedule listing a large number of commonly performed lighting efficiency tasks. These tasks include everything from simple retrofits of existing fluorescent fixtures, to new technology replacement fixtures. The successful bidder committed themselves to the specific unit price for the life of the contract, with a stipulated annual cost-of-living adjustment. The unit price included all labor and materials associated with completing the task in each unit price description. All labor costs are based on Federal and State prevailing wage requirements. In the 2004, and the subsequent 2010 RFP, provisions were made for other public agencies to utilize the competitively bid RFP for their own lighting projects. Each city or other public agency could reference and "piggyback" the County's bidding process and solicit proposals from the County's contracted vendor, without having to repeat the bidding process. The contractor (Sylvania) must adhere to the same pricing as defined in the County contract. Piggybacking is a practice accepted in the California Public Contract Code, as long as it can be demonstrated that: 1. The work being undertaken is clearly consistent with the work defined in the original RFP. 2. The RFP is of recent origin (interpreted by most agencies as three (3) years or less). 3. The pricing is consistent with the original RFP. The 2010 RFP clearly requires the successful bidder to make unit pricing available to any public agency that chooses to piggyback on the agreement. The following is a list of public agencies that have taken advantage of the piggyback options of the 2004 and 2010 lighting services agreement: • City of Ventura • City of Oxnard • Ojai Unified School District • Ventura County Office of Education • Gold Coast Transit District • City of Thousand Oaks • Conejo Park and Recreation District • City of Santa Paula • City of Fillmore • City of Port Hueneme • City of Ojai 68 Honorable City Council July 20, 2011 Page 6 The current contract has a term from January, 2011 to January, 2013, with three 1-year extensions, if mutually agreed upon by the County and Sylvania. Staff recommends `piggybacking' the County of Ventura Request for Proposals No. 5554, for Lighting Efficiency Services, Issued September 09, 2010, and Contract No. 6293 between the County of Ventura and Sylvania Lighting Services Corporation, entered on January 20, 2011. FISCAL IMPACT The City of Moorpark obtained $148,600 from the EECBG in 2009. Phase I, which included the replacement of seven (7) HVAC units, was completed in 2010 at a total cost of $76,746. $71,854 is available for the proposed lighting retrofit project. A cost summary follows: Cost Summary: Energy Efficiency and Conservation Block Grant (EECBG) 148,600 Phase I (HVAC replacement project 2010) 76,746 EECBG Remaining Balance 71,854 Active Adult Center 9,350 Community Center 15,245 City Hall Administration Building 41,851 Development Services Building 13,637 Library 12,445 Project Investment 92,528 (35) task lights @ $150 ea. 5,250 10% Contingency 9,778 Sub-total Project Investment 107,556 EECBG Remaining Balance (71,854) Total Project Investment 35,702 Total Estimated SCE Rebates (11,268) Total Net Project Investment 24,434 The total project cost was excluded from the fiscal year 2011/12 spending plan and a budget amendment of $107,556 is required in the Facilities Division (7620). $71,854 will be appropriated from the Other State/Federal Grant Fund (2609), the $13,690 from the Library Services Fund (1010) and the remaining $22,012 will come from the General Fund (1000). Staff anticipates $11,268 in Southern California Edison (SCE) rebates to partially offset this initial investment. 69 Honorable City Council July 20, 2011 Page 7 STAFF RECOMMENDATION (ROLL CALL VOTE) 1. Approve retrofitting the existing lighting at the Active Adult Center, Community Center, City Hall Administration Building, Development Services Building, Civic Center Parking Lot and Library Parking Lot; and 2. Award a contract to Sylvania Lighting Corporation and authorize the City Manager to execute an Agreement at a cost of $92,528 with approval for a contingency not to exceed $9,252, subject to final language approval by City Manager and City Attorney; and 3. Adopt Resolution No. 2011- amending the FY 2011/12 budget to appropriate $107,556 from various funds for the Lighting Retrofit. Attachments: 1. Resolution No. 2011 - 2. Sylvania Lighting Upgrade Proposals 3. Humanscale Lighting Audit Summary 70 Honorable City Council July 20, 2011 Page 8 RESOLUTION NO. 2011- A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF MOORPARK, CALIFORNIA, AMENDING THE FISCAL YEAR 2011/12 BUDGET TO APPROPRIATE $107,556 FROM VARIOUS FUNDS FOR THE RETROFIT OF EXISTING LIGHTING SYSTEMS AT THE ACTIVE ADULT CENTER, COMMUNITY CENTER, CITY HALL ADMINISTRATION BUILDING, DEVELOPMENT SERVICES BUILDING, CIVIC CENTER PARKING LOT AND LIBRARY PARKING LOT WHEREAS, a staff report has been presented to City Council discussing the need to retrofit the existing lighting systems at the Active Adult Center, Community Center, City Hall Administration Building, Development Services Building, Civic Center Parking Lot and Library Parking Lot in the amount of$107,556; and WHEREAS, On September 18, 2009 the City was awarded $148,600 from the Energy Efficiency and Conservation Block Grant Programs (EECBG) under the American Recovery and Reinvestment Act of 2009 and $76,746 has been expended for the replacement of seven (7) Heating, Ventilation and Air Conditioning units at the Active Adult and Community Center facilities, with a remaining balance of $71,854 available to partially fund this project; and WHEREAS, on June 15, 2011 the City Council adopted the Operating and Capital Improvement Projects Budget for fiscal year 2011/12, which did not include any funding for the project; and WHEREAS, staff is requesting an aggregate budget amendment of $107,556 in the Facilities Division (7620) to fully finance the project, which includes the budget increase of $71,854 from the Other State/Federal Grants Fund (2609), $13,690 from the Library Services Fund (1010), and $22,012 from the General Fund (1000); and WHEREAS, Exhibit "A" hereof describes said budget amendment and its resultant impact to the budget line items. NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF MOORPARK DOES HEREBY RESOLVE AS FOLLOWS: SECTION 1. That an aggregate expenditure budget increase of $107,556 for the retrofitting of existing lighting systems at the Active Adult Center, Community Center, City Hall Administration Building, Development Services Building, Civic Center Parking Lot and Library Parking Lot more particularly described in Exhibit "A" attached hereto is hereby approved. SECTION 2. The City Clerk shall certify to the adoption of this resolution and shall cause a certified resolution to be filed in the book of original resolutions. 71 Honorable City Council July 20, 2011 Page 9 PASSED AND ADOPTED this 20th day of July, 2011. Janice S. Parvin, Mayor ATTEST: Maureen Benson, City Clerk Attachment: Exhibit A— Budget Amendment 72 Honorable City Council July 20, 2011 Page 10 EXHIBIT A BUDGET AMENDMENT FOR VARIOUS FUNDS FOR THE RETROFITTING OF EXISTING LIGHTING SYSTEMS AT THE ACTIVE ADULT CENTER, COMMUNITY CENTER, CITY HALL ADMINISTRATION BUILDING, DEVELOPMENT SERVICES BUILDING, CIVIC CENTER PARKING LOT AND LIBRARY PARKING LOT FY 2011/12 FUND ALLOCATION FROM: FUND TITLE FUND ACCOUNT NUMBER AMOUNT Other State/Federal Grant 2609-5500 $71,854 General Fund 1000-5000 $22,012 Library Fund 1010-5500 $13,690 Total $107,556 DISTRIBUTION OF APPROPRIATION TO EXPENSE ACCOUNTS: BUDGET NUMBER CURRENT BUDGET REVISION ADJUSTED BUDGET 2609-7620-0000-9252 $ - $62,806 $62,806 2609-7620-7704-9252 $ - $9,048 $9,048 1000-7620-7704-9252 $ 4,000 $1,237 $5,237 1000-7620-0000-9252 $ - $5,775 $5,775 1000-7620-2012-9252 $ - $15,000 $15,000 1010-7620-0000-9252 $ 12,500 $13,690 $26,190 ITotal $ 16,500 $107,5561 $124,0561 Finance approval: 6)A� 73 ATTACHMENT 2 City of Moorpark Senior Center Financial Summary Annual Lighting Energy Savings $ 1,715 Annual Lamp Maintenance Savings 726 Annual Air Conditioning Savings 529 Total Annual Savings $ 2,969 Project Investment $ 9,350 Estimated VCREA Rebate $ 1,301 Net Project Investment $ 8,049 Project Payback Period (Years) 2.71 Return on Investment 37% Annual Lighting Costs $7,000 1 5,910 $6,000 $5.000 I 3,069 $4,000 i .—.. —.... DAir Conditioning $3,GOO 01-amp Maintenance a Lighting Energy— $2,000 $1,000 F,aisting Proposed SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 74 Senior Center EIOSTIMI(i •..PROPOSED. C.di, Y— D'-"'Pt—, vv�tf' k. K.1, Qty D-cr.10—, %*J,itt' k. K.1, Qfy. Ope,atinct C—t, Operv..g Coms Sen—--,y. Price Price Retrofit to 2 lamp 2x4-4 lamp T12 Supersaver T8 and PSH B 2,340 Prismatic 144 1 2,359 7 ballast with reflector 62 0 1,016 7 $ 354 $ 152 $ 23 $ 91 $ 640 Retrofit to 2lamp Miscellaneous 2 Supersaver T8 and PSX C 2.340 lamp 4'T12 fixtures 72 1 1,685 10 ballast 40 0 936 10 $ 253 $ 140 $ 21 $ 63 $ 633 Retrofit to 3-2'T8 lamps Miscellaneous 2x2- with reflector and FE 2,340 U lamp T12 Fixtures 72 2 4,044 24 electronic ballasts 37 1 2,078 24 $ 607 $ 312 $ 47 $ 86 $ 2,064 Retrofit to 4 lamp Miscellaneous 6 Supersaver T8 and PSH 2,340 lamp T12 Fbdures 171 3 6,402 16 ballast 124 2 4,643 16 $ 960 $ 696 $ 104 $ 82 $ 1,320 Miscellaneous 60 Watt Incandescent F 2,340 Fixtures 60 2 5,195 37 Retrofit to 14 watt LED 14 1 1,212 37 $ 779 $ 182 $ - $ 76 $ 2,812 2-20 watt Incandescent Exit Replace with LED Exit IS 8,760 Signs 40 0 350 1 sign with battery backup 2 0 18 1 $ 53 $ 3 $ $ 103 $ 103 Small enclosed Install Dual switching H 2,340 offices and areas 0 5 Occupancy Sensor 0 5 $ - $ $ $ 161 $ 804 Install Dual Technology Ceiling Occupancy 1 234 Larger Areas 0 4 Sensors 0 4 $ $ - $ $ 243 $ 974 8.46 20,034 104 4.23 9,902 1 104 $ 3,005 S 1,486,$ 195 $ 9,360 Energy Sayings Summary kW: 4.23 kWh: 11,433.61 1300.E 1 Cost r kWh: $0.160 Total Savfn a: $ 1,716.04 SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally U1 AC SAVINGS CALCL."LATIONS Fluorescent Lamps transform only about 30%of the energy they draw into light. The rest is converted to heat—wY places a burden on a facility's cooling system. By using fewer and more efficient lamps and ballasts, excess hea removed,making cooling a facility easier and cheaper. This is an estimate of how much energy will be saved by redu air conditioning operation based on a formula developed by ASHRAE. It is accepted by most utilities as the stand formula for quantifying A/C savings. Lighting KW removed 3.86 BTU per KW 3,413 X A/C KW per Ton 1.07 Subtotal 14,096 / BTU per Ton 12,000 Subtotal 1.17 Average Burn Hours per Year 3,000 A/C Utilization Factor 1.00 X Cost per kW/h 0.15 ANNUAL A/C SAVINGS $529 Environmental Impact Analysis Reducing energy consumption directly reduces harmful emissions from power plants. As a Manufacturing Ally in the E Green Lights program,Parke Industries, Inc. supports the promotion of energy-efficient lighting technologies in the against the proliferation of pollution. This analysis estimates the amounts of harmful emissions that would be preve through the implementation of this project. It is based on figures supplied by the Environmental Protection Agency. Environmental Emission Reductions i 20,000 (� 18,000 I Legend 16,000 14,000 okW/h Reduction ... 11,434 12,000 LE3O2 reduction(Ib; 10,000 duction(oz 8,000 reduction(oz 6,000 4,000 2,342 2,000 1,00s 0 . ...... Kilowatt Carbon N10ogen Sulfur Hours Dioxide Oxides Dioxide SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 7/8/2011 76 City of Moorpark Community Center Revised Financial Summary Annual Lighting Energy Savings $ 3,337 Annual Lamp Maintenance Savings 761 Annual Air Conditioning Savings 759 Total Annual Savings $ 4,856 Project Investment $ 15,245 Estimated VCREA Rebate $ 2,334 Net Project Investment $ 12,912 Project Payback Period (Years) 2.66 Return on Investment 38% Annual Lighting Costs $10,000 9,140 $9,000 $8,000 $7,000 5,212 $6,000 _ $5,000 oAir Conditioning ■Lamp Maintenance $4,000 ■Lighting Energy $3,000 - - $2,000 $1,000 $0 Fsis6ag Proposed SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 77 Community Center EXISTING-., ...: s.n .`i _;,..-,.:PROPOSED I —1"'q I wu- F x Flrop-vd ket-fit Pro... Pro Propo-d Pro C w r-1 i I Prop—d An—A E,t—led A.-11 Unit Fxtended cry. . a Retrofit to 2 lamp 2x4-3 lamp T12 Supersaver T8 and PSN A 2,960 Prismatic 115 3 10,212 30 ballast with reflector 50 2 4,440 30 $ 1,532 $ 666 $ - $ 91 $ 2,744 Retrofit to 2 lamp 2x4-4 lamp T12. Supersaver T8 and PSH B 1 2,960 Prismatic 144 3 9,377 22 ballast with reflector 62 1 4,037 22 $ 1,407 $ 606 $ - $ 91 $ 2,012 Retrofit to 2 lamp Miscellaneous 2 Supersaver T8 and PSX C 1 2,960 lamp 4'T12 fixtures 72 1 2,557 12 ballast 40 0 1,421 12 $ 384 $ 213 $ $ 63 $ 760 Retrofit to 3-278 lamps Miscellaneous 2x2- with reflector and D 1 2,960 U lamp T12 Fixtures 72 1 2,344 11 electronic ballasts 37 0 1,205 11 $ 352 $ 181 $ $ 86 $ 946 Retrofit to 4 lamp Miscellaneous 6 Supersaver T8 and PSH E 2,960 lamp T12 Fixtures 171 2 6,074 12 ballast 124 1 4,404 12 $ 911 $ 661 $ $ 82 $ 990 2-20 watt Incandescent Exit Replace with LED Exit F 8,760 Signs 40 0 3.154 9 sign with battery backup 2 0 158 9 $ 473 $ 24 $ $ 103 $ 929 50 watt HPS Replace with 21 watt LED G 4.380 Wallpacks 66 1 3,180 11 Wallpack 21 0 1,012 11 $ 477 $ 152 S $ 467 $ 5,137 Exterior 250 watt HPS Wallpack Replace with 112 Watt H 4,380 Fixtures 295 1 2,584 2 LED Wall ak 64 0 561 2 $ 388 $ 84 $ $ 864 $ 1,728 12.00 39 483 109 6.62 17 238 109 $ 6,922 $ 2,586 $ $ 16,245 Energy Savings S"-ry kW: 6.3f kWh: 12,216.10 0 Cost per kWh: $0.160 ToW Sarin s: f 3,336,77 SYLVANIA LIGHTING SERVICES An EPA Green Ughts Ughting Management Company AIM CO Fluorescent Lamps transform only about 30%of the energy they draw into light. The rest is converted to heat—wf places a burden on a facility's cooling system. By using fewer and more efficient lamps and ballasts,excess hea removed,making cooling a facility easier and cheaper. This is an estimate of how much energy will be saved by redw air conditioning operation based on a formula developed by ASHRAE. It is accepted by most utilities as the stand formula for quantifying A/C savings. Lighting KW removed 5.54 BTU per KW 3,413 X A/C KW per Ton 1.07 Subtotal 20,232 ! BTU per Ton 12,000 Subtotal 1.69 Average Burn Hours per Year 3,000 A/C Utilization Factor 1.00 X Cost per kW/h 0.15 ANNUAL A/C SAVINGS $759 Environmental Impact Analysis LL) Reducing energy consumption directly reduces harmful emissions from power plants. As a Manufacturing Ally in the E Green Lights program,Parke Industries, Inc.supports the promotion of energy-efficient lighting technologies in the against the proliferation of pollution. This analysis estimates the amounts of harmful emissions that would be preve through the implementation of this project. It is based on figures supplied by the Environmental Protection Agency. Environmental Emission Reductions 40,000 (� �8 35,000 Legend 30,000 --- akW/h Reduction 25,000 22,245 13CO2 reduction(Ibs 20,000 1 ....... aNOx reduction(oz 15,000 I ❑SO2 reduction(oz 10,000 .. i 4,556 5,000 0 :.. j Kilowatt Carbon Nitrogen Sulfur Hours Dioxide Oxides Dioxide SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 7/8/2011 79 City of Moorpark City Hall-Administrative Services Revised Financial Summary Annual Lighting Energy Savings $ 6,674 Annual Lamp Maintenance Savings 678 Annual Air Conditioning Savings 1,162 Total Annual Savings $ 8,514 Project Investment $ 41,851 Estimated VCREA Rebate $ 4,538 Net Project Investment $ 37,313 Project Payback Period (Years) 4.38 Return on Investment 23% Annual Lighting Costs $16,000 14,610 $14,000 t 5,960 $12,000 $10,000 $6,000 DAir Conditioning ■Lamp Maintenance $6,000 ■Lighting Energy i $4,000 $2,000 $o Existing Proposed SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 80 City Hall Administrative Services iEIOSTINO . .:4,:PROP.OSED- (""j, Y,jr t"' Vh W. K I,t. I, Ov'-Pt"). W'tt' ""'h or,' Operating Costs Operating Costs St-sor savings P-it P" Retrofit to 2 lamp Supersaver TS with PSH 2x"..lamp T12 program start ballast and A 2,665 Prismatic 144 4 10,362 27 reflector 62 2 4,461 27 $ 1,554 $ 669 $ 167 $ 91 $ 2,469 Retrofit to 2 lamp Supersaver T8 with PSN 2x4-3 lamp T12 program start ballast and B 2,665 Prismatic. 112 2 6,567 22 reflector 50 1 2,932 22 $ 985 $ 440 $ 110 $ 91 $ 2,012 2x2-2 U lamp. Retrofit to 3-2'T8 lamps Flu&escents with reflector and C 2,665 Fixtures 72 1 1,535 8 electronic ballast 37 0 789 8 $ 230 $ 118 $ 30 $ 86 $ 688 Retrofit to 4 lamp 2lamp 8'T12 Supersaver T8 and PSX D 2,665 Pendant Fixtures; 134 2 5,714 16 ballast 80 1 3,411 16 $ 857 $ 512 $ $ 99 $ 1,592 50 WetUI-Ift Replace with LED E 4,380 Wallpacks, 63 0 828 3, Wallpacks 21 0 276 3 $ 124 $ 41 $ $ 467 $ 1,401 176 waft'Metal F 4,380 Halide Poles 215 1 3,767 4 Retrofit to LED Kits 55 0 964 4 $ 565 $ 145 $ $ 565 $ 2,260 176* Metal G 4,380 Halide Fixtures 215 0 1,883 2 Retrofit to LED Kits .55 0 482 2 $ 283 $ 72 $ 565 $ 1,130 400 Watt Metal Heilde Exterior Poles Replace with 175 waft H 4,380 fixtures'. 458 9 40,121 20 LED Fixtures 175 4 15,330 20 $ 6,018 $ 2,300 $ 1,228 $ 24,554 100 waft,. Inc*hdest+ent Replace with LED I<; 1,000 Wallpacks: 100 0 400 4; Wallpacks 21 0 84 4 $ 60 $ 13 $ $ 467 $ 1,868 Install Ceiling Occupancy 1 2,184 OffioeAreas 0 0 Sensors - 0 8 $ $ J4309 $ Install Wall Occupancy K 2,184 Office Areas 0 - 0 Sensors 0 12 $ - $ $ - $ 161 $ 1,929 20.11 71,176 106 8.33 28,728 126 $ 10,676 S $ 307 $ 41,861 Energy Savings Summary kw: n7a 44490e 204539 Cost ar kWh: $0.60 Total Saw N: 6,673.116 SYLVANIA LIGHTING SERVICES CD An EPA Green Light.Lighting Management Company AIM I-A L�(,yhtin((Z Proposal Fluorescent Lamps transform only about 30%of the energy they draw into light. The rest is converted to heat—wt places a burden on a fcwAtys coding system. By using fewer and more efficient lamps and ballasts,excess hea removed,making cooling a facility easier and cheaper. This is an estimate of how much energy will be saved by redur air conditioning operation based on a formula developed by ASHRAE. It is accepted by most utilities as the stand formula for quantifying A/C savings. Lighting KW removed 9.79 BTU per KW 3,413 X A/C KW per Ton 1.07 Subtotal 35,752 I BTU per Ton 12,000 Subtotal 2.98 Average Burn Hours per Year 2,600 A/C Utilization Factor 1.00 X Cost per kW/h 0.15 ANNUAL A/C SAVINGS $1,162 Environmental Impact Analysis Reducing energy consumption directly reduces harmful emissions from power plants. As a Manufacturing Ally in the E Green Lights program,Parke Industries, Inc.supports the promotion of energy-efficient lighting technologies in the against the proliferation of pollution. This analysis estimates the amounts of harmful emissions that would be preve through the implementation of this project. It is based on figures supplied by the Environmental Protection Agency. Environmental Emission Reductions 80,000 (k S9 70,000 Legend 60,000 okW/h Reduction 50,000 44,493 E3CO2 reduction(Ib: 40,000 aNOx reduction(oz 30,000 .` oSO2 reduction(oz 20,000 .. 9,112 10,000 3,915 0 ... .. . ..... Kilowatt Carbon Nitrogen Sulfur Hours Dioxide Oxides Dioxide SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 7/8/2011 82 City of Moorpark City Hall-Development Services Financial Summary Annual Lighting Energy Savings $ 2,596 Annual Lamp Maintenance Savings 532 Annual Air Conditioning Savings 531 Total Annual Savings $ 3,658 Project Investment $ 13,637 Estimated VCREA Rebate $ 2,395 Net Project Investment $ 11,242 Project Payback Period (Years) 3.07 Return on Investment 33% Annual Lighting Costs $6,000 1 5,623 $5,000 I 2,262 $4,000 $3,000 OAir Conditioning ■Lamp Maintenance $2 000 ■Lighting Energy $1,000 $o - -- Existing Proposed SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 83 City Hall-Development Services p ,: ::EIOSIMG ",-.k ,. ,,_.w-.: .. -=.6; ,RO.OSED.• Retrofit to 2 lamp 2x44 lamp T12 Supersaver T8 and PSH r A 2,665 PriliMatic 144 8 21,107 55 ballast and reflector 62 3 9,088 55 $ 3,166 $ 1,363 $ 341 $ 91 $ 5,030 Retrofit to 2 lamp Misctlanefus 2 }. Supersaver T8 and PSX B 2,665 lamp 4'T12 factures 72 0 192 1 ballast 40 0 107 1 $ 29 $ 16 $ 4 $ 63 $ 63 12)(2-2 U lamp Retrofit to 3 lamp 2' Fluorescents Supersaver T8 and PSX C 2,665 Fixtures - 72 0 1 959 5 ballast with reflector 37 0 493 5 $ 144 $ 74 $ 18 $ 86 $ 430 100 Watt' Incandescent Replace with 21 watt LED D 4,380 Wellpacks 100 0 1,314 3 Well pack 32 0 420 3 $ 197 $ 63 $ $ 467 $ 1,401 12-20 watt Replace with new LED Incandescent Exit.- Exit Sign with battery E 8,760 Signs 40 0 1,051 3 backup 2 0 53 3 $ 158 $ B $ $ 103 $ 310 / 100 watt Metal Replace with 42 watt LED F 1.000 Halide Wellpacks 126 1 630 5 Wall pack 42 0 210 5 $ 95 $ 32 $ $ 559 $ 2,795 Install Ceiling Occupancy G 2,184 Office Areas 0 0 Sensors 0 - 4 $ - I $ $ $ 286 $ 1,144 Install Wall Occupancy H 2,184 Office Areas 0 - - 0 Sensors 0 - - 16 $ - $ $ $ 154 $ 2,464 9.40 25,263 72 3.96 10,370 1 92 $ 3,788 $ 1 666 $ 363 $ 13,637 Energy Savings S"—'Y kW: 6.K kwh: 17,004.78 2411.82 Cost per kWh; $0.160 Total Sevin s: f 2,895.72 SYLVANIA LIGHTING SERVICES 00 An EPA Green Lights Lighting Management Company My lt. Fluorescent Lamps transform only about 30%of the energy they draw into light. The rest is converted to heat--wt places a burden on a facility's coding system. By using fewer and more efficient lamps and ballasts,excess hea removed,making coding a facility easier and cheaper. This is an estimate of how much energy will be saved by redu air conditioning operation based on a formula developed by ASHRAE. It is accepted by most utilities as the stand formulator quantifying A/C savings. Lighting KW removed 4.47 BTU per KW 3,413 X A/C KW per Ton 1.07 Subtotal 16,324 / BTU per Ton 12,000 Subtotal 1.36 Average Burn Hours per Year 2,600 A/C Utilization Factor 1.00 X Cost per kW/h 0.15 ANNUAL A/C SAVINGS $531 Environmental impact Analysis Reducing energy consumption directly reduces harmful emissions from power plants. As a Manufacturing Ally in the E Green Lights program,Parke Industries, Inc. supports the promotion of energy-efficient lighting technologies in the against the proliferation of pollution. This analysis estimates the amounts of harmful emissions that would be preve through the implementation of this project. It is based on figures supplied by the Environmental Protection Agency. Environmental Emission Reductions 30,000 1� �7 25,000 I Legend 20,000 FokW/h Reduction 17 305 ©CO2 reduction(Ibt 15,000 { ONOx reduction(oz 10,000 OS02 reduction(oz 5,000 3,541 1,523 0 ...: ... Kilowatt Carbon Nitrogen Sulfur Hours Dioxide Oxides Dioxide SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 7/8/2011 85 PROJECT OVERVIIAV City of Moorpark Library Financial Summary Annual Lighting Energy Savings $ 1,616 Annual Lamp Maintenance Savings 88 Annual Air Conditioning Savings - Total Annual Savings $ 1,703 Project Investment $ 12,445 Estimated VCRF,A Rebate $ 700 Net Project Investment $ 11,745 Project Payback Period (Years) 6.90 Return on Investment 15% Annual Lighting Costs $3,000 2,712 $2,500 $2,000 1,008 $1.500 oar Conditioning ■Lamp Maintenance $1,000 { ■Lghtirg Energy _J $500 � --- $0 Existing Proposed SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 86 Library EXISTING ::'*a C:'-tPROPOSED 400 Watt HIPS: Replace with 175 watt H 4,380 Exterior Fixture 460 3 12,089 6 LED Fixture 175 1 4,599 6 $ 1,813 $ 690 $ $ 1,227 $ 7,363 250 Watt HPS Replace with 100 watt 1 4,380 Exterior Fixture 295 1 3,876 3 LED Fixture 100 0 1,314 3 $ 581 $ 197 $ $ 963 $ 2,890 70 watt HIPS Replace with 42 LED J 1 4,380 lWa 11 acks 83 0 1,454 4 wall pack 42 0 736 4 $ 218 $ 110 $ $ 548 $ 2,192 3.98 17,419 13 1.62 6 649 13 S 2 613 $ 997 $ S 12,445 Energy Savings Summary kW: 2.K kWh; 10,770.12 0.00 Cost of kWh: $0.160 Total Savin s: 6 1,616.68 SYLVANIA LIGHTING SERVICES 00 An EPA Green Lighh Lrght,ng Management Company Ally Fluorescent Lamps transform only about 30%of the energy they draw into light. The rest is converted to he --wt places a burden on a facilitys cooling system. By using fewer and more efficient lamps and ballasts,excess hea removed,making coding a facility easier and cheaper. This is an estimate of how much energy will be saved by radix air conditioning operation based on a formula developed by ASHRAE. It is accepted by most utilities as the stand formula for quantifying A/C savings. Lighting KW removed 0.00 BTU per KW 3,413 X A/C KW per Ton 1.07 Subtotal 0 / BTU per Ton 12,000 Subtotal 0.00 Average Burn Hours per Year 3,000 A/C Utilization Factor 1.00 X Cost per kW/h 0.15 ANNUAL A/C SAVINGS s0 Environmental Impact Analysis I Reducing energy consumption directly reduces harmful emissions from power plants. As a Manufacturing Ally in the E Green Lights program, Parke Industries, Inc.supports the promotion of energy-efficient lighting technologies in the against the proliferation of pollution. This analysis estimates the amounts of harmful emissions that would be preve through the implementation of this project. It is based on figures supplied by the Environmental Protection Agency. Environmental Emission Reductions Ihlo�s 18,000 16,000 + Legend 14,000 12,000 10,770 okW/h Reduction 10,000 aCO2 reduction(IbE 8,000 I ONOx reduction(oz 000 6, .. L 13S02 reduction(oz 4,000 2,206 — .. .. 2,000 -::....... 948 _...:.: Kilowatt Carbon Nitrogen Sulfur Hours Dioxide Oxides Dioxide SYLVANIA LIGHTING SERVICES An EPA Green Lights Lighting Management Company Ally 7/8/2011 88 ATTACHMENT 3 City of Moorpark Lighting Audit Summary Performed by: Patrick McDonald Humanscale 89 Summary: Humanscale was tasked with auditing the lighting levels for the employees at the City of Moorpark. Specifically,we were to evaluate the lighting levels at each workstation as well as general office areas to identify opportunities to decrease energy usage while increasing employee comfort and productivity. There are challenges that exist with office lighting, specifically as it relates to lighting where employees are working on a computer as well as referencing documents. As supported by the Illuminating Engineering Society of North America (IESNA),working at a computer requires light levels in the range of 10 footcandles,while referencing a document can require as much as 100 footcandles. In addition to those varying light levels, people require different light levels based on their individual visual systems. Findings: There are significant opportunities to decrease energy usage in two areas. First are the private offices. All of the offices, as documented below, are too bright to comfortably work on a computer monitor and not bright enough where the employees reference documents. At full power, or three illuminated 32 watt bulbs,the average footcandles on the computer were 27.1. Average footcandles on the documents where employees work were at 36.4. You can decrease the energy usage in these private offices by using two bulbs rather than three and adding adjustable task lights. With two bulbs illuminated the average light levels at the computer drop to 24.6 and drop to 28.8 at the documents. When you add an adjustable task light,you can keep the 24.6 footcandles at the monitor and increase the light levels at the document by an additional 100 footcandles. This decrease in overhead lighting can represent up to a 33.3%decrease in the energy used by the fixture,going from 3 bulbs at 32 watts to 2 bulbs at 32 watts. Further savings can be realized by decreasing the wattage from 32 watt bulbs to 25 watt bulbs. The second area of opportunity to save on energy usage is in the general office area,which includes walkways as well as cubicles. Generally speaking,this area is significantly over-illuminated in some areas and under-illuminated in others. The over-illuminated areas include the walkway between the private offices and the row of cubicle walls. OSHA recommends light levels of approximately 30 footcandles for general office areas. Much of the space is illuminated to 50 footcandles,with one area as high as 61 footcandles. There are two different fixtures in the drop-down ceiling of the general office space. Some of the fixtures have three 32 watt bulbs and some have four 32 watt bulbs. 90 The city of Moorpark may be able to decrease their overall energy usage by removing the center bulb in the fixtures with three bulbs, and the two middle bulbs in the fixtures with four bulbs. Doing so will not only decrease the energy usage, but will cut down on costs to purchase new bulbs as well as shrink the maintenance costs associated with replacing bulbs. However, if the City of Moorpark decreases the amount of light from the overhead fixtures,they will need to increase the level of light on employee workstations by providing adjustable task lights which enable an employee to put the light on their documents when they need to illuminate the documents. Financial impact: Decreasing the energy usage in the building will have a positive financial impact on the City of Moorpark. While there will be a one-time cost associated with purchasing adjustable task lights,the cost of the task light investment will be recouped over time. Annual financial savings from decreasing energy usage(assumes removing 132 watt bulb in three bulb fixtures and 2 32 watt bulbs in four bulb fixtures): $2,141.60. There is a one-time cost associated with purchasing adjustable task lights. When selecting any task light, a specific criterion should be followed to ensure that the light works the way an employee needs it to work. Failure to follow a criteria will likely lead to selecting a light that does not work as required, and will cause the employee to be forced to read documents without the proper level of illumination. The following criteria should be applied to all task lights that are being evaluated: 1. Able to adjust the position of the light with one hand. This needs to be accomplished without the light falling over. 2. Remain cool to the touch. If a light gives off too much heat, it causes a safety and comfort problem. 3. Needs to have a large enough footprint of light that allows it to illuminate the documents without having to constantly move the light. 4. Provide a neutral white light temperature. According to IESNA,this temperature is 3500 Kelvin. 5. Use only one light source or bulb. This is specific to LED lights. Any LED task light needs to illuminate the documents using only one light source as opposed to multiple light sources. 6. Be sustainable, in terms of energy usage, life span, and recyclability. The one-time cost for the adjustable task lights may be approximately$3,000.00 Recommendations: 1. Remove the center bulb from the fixtures which use three bulbs. 91 2. Remove the two middle bulbs from the fixtures which use four bulbs. I Provide adjustable task lighting to the employees who work on computers and reference documents. Ensure that the criterion set above is followed when selecting an adjustable task light. 92